UV Viewing Cabinet
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The UV Viewing Cabinet is a precision instrument designed to detect and analyze fluorescent substances in a wide range of materials. By providing controlled ultraviolet (UV) and visible light exposure, it allows accurate observation, comparison, and documentation of fluorescence for quality control, impurity detection, and material authentication.
Application
(1) Coatings and paints: Detect and analyze phosphors in plastics, paints, and coatings.
(2) Aluminum foil: Examine fluorescent substances in aluminum foil and related materials.
(3) Paper: Test for fluorescent substances in various types of paper.
(4) Plastics: Detect fluorescence in plastics and other polymer materials.
(5) Quality control: Evaluate material uniformity and detect impurities.
(6) Research and development: Study fluorescent behavior of new compounds or coatings.
(7) Non-destructive testing: Examine samples without damaging or altering them.
Standards
(1) GB/T 16422.3 – Fluorescent inspection methods for non-metallic materials.
(2) GB/T 14522 – Material fluorescence testing standards.
(3) ASTM G154 – Standard practice for fluorescent testing of non-metallic materials.
(4) ISO 4892-3 – Plastics exposure to laboratory light sources for fluorescence testing.
(5) SAE J2020 – Automotive exterior parts fluorescence inspection.
Features
(1) Integrated UV light sources at 254 nm (short-wave) and 365 nm (long-wave) for excitation of different fluorescent compounds.
(2) D65 standard visible light source for comparison under controlled white light conditions.
(3) Camera system for capturing and documenting sample fluorescence images.
(4) Light-tight chamber for controlled environment and operator protection.
(5) UV filter (200×50 mm) to regulate emitted UV light.
(6) Host unit for centralized control and image analysis.
(7) Picture comparison function for side-by-side observation of samples under UV or visible light.
(8) Non-destructive testing, supporting quality control, impurity detection, and material authentication.
Parameters
| Parameter | Specification |
|---|---|
| Ultraviolet wavelength | 254 nm, 365 nm |
| Filter size | 200 × 50 mm |
| Visible light | D65 standard illuminant |
| Power supply | AC 220V, 50Hz |
| Standard configuration | Host unit, picture comparison system |
Accessories
(1) Host unit
(2) Camera system for image capture
(3) UV filters
(4) Picture comparison system
(5) Power cable and manual
Test Procedures
(1) Place the sample inside the UV Viewing Cabinet.
(2) Select the UV wavelength (254 nm or 365 nm) or the visible light source (D65) as required.
(3) Activate the light source and allow the sample to be illuminated under controlled conditions.
(4) Observe the fluorescence visually or capture images using the integrated camera system.
(5) Use the picture comparison function to analyze differences between samples or compare with reference standards.
(6) Record and document the observations for quality control or R&D purposes.
Maintenance Information
(1) Keep the chamber clean and free from dust or residues that may affect UV exposure.
(2) Inspect UV lamps and filters periodically for damage or reduced output.
(3) Handle the camera system carefully and avoid exposure to excessive UV light.
(4) Ensure all electrical connections are secure and the power supply is stable.
(5) Avoid direct eye exposure to UV light during operation.
(6) Follow manufacturer guidelines for servicing and lamp replacement.
Send product request
Other supplier products
| DIN 75201 fogging tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Fogging Tester is mainly used to test the evaporation of volatile components ... | |
| Mask Visual Field Tester丨Mask Visual Field Test machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application: Mask Visual Field Tester to determine whether field of vision under the mask ... | |
| Blowing Sand Test Chamber with Adjustable Wind Speed | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)GB/T 2423.37-2006 Environmental Testing – Part 2: Test Methods – ... | |
| CE Certified Thermal Constants Analyzer for R&D Laboratory | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The analyzer supports multiple internationally recognized test met... | |
| Battery Cell Short Circuit Failure Tester UL Standard Certified | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) IEC 62133-2012 – Safety Requirements for Portable Second... |
Same products
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Seller: Kelilong Electron Co.,Ltd | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... | |
| PH-808 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-808 Range PH ~14.00PH Temp 0~50℃ ... |