Infusion Pump Flow Rate Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Infusion Pump Flow Rate Tester is specifically designed for testing the flow rate of sodium chloride solution in infusion sets. It is suitable for use by medical device manufacturers, third-party testing institutions, medical device inspection and research institutes, and research and educational institutions.
Applications
The infusion set flow rate tester is an instrument specifically designed for measuring and monitoring the flow rate of infusion sets. Its main uses include: - Flow Rate Measurement: Precisely measure the flow rate of the infusion set, usually displayed in milliliters per hour (ml/h) or drops per minute (gtt/min). - Flow Monitoring: Monitor the changes in flow rate in real - time during the infusion process, and promptly detect abnormal flow rate situations, such as the flow rate being too fast, too slow, or blocked, to ensure the safety and effectiveness of the infusion process. - Alarm Function: When the infusion flow rate exceeds the set normal range, the tester can emit audible and visual alarm signals to remind medical staff to take timely action and avoid potential medical risks. - Data Recording and Storage: Record and store information such as flow rate data and time during the infusion process, which is convenient for medical staff to view and analyze, and helps track and evaluate the patient's infusion treatment.
Standards
GB 8368 - 2018 : Disposable Infusion Sets
Features
1. Industrial-grade capacitive touch screen with a menu-driven interface for easy and convenient operation;
2. The fixture is suitable for various types of catheters;
3. Equipped with a miniature printer for easy printing of test results.
Technical Parameters
| Parameter | Specification |
|---|---|
| Testing Range | Wide flow rate testing range (e.g., 1 - 2000ml for some testers), adapting to different types/specifications of infusion sets (varies by catheter specifications) |
| Testing Accuracy | High accuracy for flow rate measurement (e.g., ±5ml/h or ±0.1gtt/min, etc.) to ensure test result accuracy |
| Static Water Level Height | Adjustable range: usually 0 - 1000mm, meeting requirements under different testing conditions |
| Temperature Control Range | Usually 5 - 90℃, simulating infusion situations under different temperature conditions |
| Fixtures | Adapt to various catheters; customized according to catheter specifications to firmly hold infusion sets of different specifications during testing |
| Flow Calculation | Adopts methods like the weighing method for flow calculation, ensuring accurate flow measurement |
| Alarm Threshold | Allows users to set the alarm threshold; triggers an alarm when the flow rate exceeds the set range |
Accessoriess
Standard accessories include: specialized fixing clamps for different types of infusion sets (for securely holding various infusion sets), connecting tubing (for setting up the flow path to complete flow rate testing), equipment calibration auxiliary parts (to ensure testing accuracy), operating manual, and calibration certificate.
Test Procedures
Infusion Flow Rate
For infusion sets with a drip rate of 20 drops/mL, the infusion set should deliver at least 1000 mL of sodium chloride solution [mass concentration p(NaCl) = 9 g/L] within 10 minutes under a static pressure head of 1 meter.
For infusion sets with a drip rate of 60 drops/mL, the infusion set should deliver at least 1000 mL of sodium chloride solution [mass concentration p(NaCl) = 9 g/L] within 40 minutes under a static pressure head of 1 meter.
Send product request
Other supplier products
| Strip evenness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Cotton yarn fiber strip analyzer is a high performance, high t... | |
| Button Impact Tester丨Button Impact Test mechine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM D5171 Applications Button Impact Tester is used to determine the impact r... | |
| Flame spread index testing equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You can apply this tester in the following scenarios: Building materials eval... | |
| Laboratory filter media test rig ISO 11057 compliant | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Media Test Rig According to ISO 11057 is designed for reliable and... | |
| Fire Testing Equipment for Flammability | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The equipment meets the following standards: ISO 12136 – Determination of... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | Seller: Kelilong Electron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | Seller: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... |