Plastic Smoke Density Tester
Introduction
The main principle of smoke density measurement is that in a particular space, the cable or material produces smoke under specific combustion or radiation conditions, and the light beam penetrating through the smoke will produce attenuation. Measuring the light transmittance and calculation will get the optical density and smoke density.
The instrument is designed and developed according to ISO5659 related standards. With the use of Conical radiation furnace, the heat flux in the chamber can be as high as 50 kW/ m2, and the sample can be positioned horizontally to test the mass loss rate of the sample. This also complies with the latest IMO test terms. Measure the amount of smoke generated when the sample is vertically exposed to a radioactive heat source at 25 kW / m2 when there is or there is no forward flame in confined space.
Using the standard ISO 5659 conical radiant heating furnace, the user can adjust the heating conditions from 10 kW㎡ into 50 kW/㎡ or 70kW/㎡.
Standards
GB/T8323.2-2008: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-1: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-2: Plastics-Smoke generation-Part2: Determination of optical density by a single-chamber test
·The tester consists of a chamber, a sample box, a radiant cone, an igniter, a light transmission and measuring device and other related control devices.
·Ergonomic design and control design; chamber with a fully open door ; door lock designed to facilitate one-time closure of the door; optimize the operation process.
·The test chamber door can be fully opened to facilitate loading and unloading samples and cleaning the box;
·Front door, hinge mounted, with window and non-transparent light shading board which can block the window, to prevent light from entering the sealed chamber.
·The controller is located on the side of the chamber for easy operation. When the door is closed, it does not affect the controller to be viewed.
·Safe flameout board, easy to replace, more secure operation.
·A gas measuring port is available for testing gas toxicity.
·The coating of the test chamber is easy to clean and resistant to chemical corrosion.
Combustion Apparatus
·Heating cone: power 2600W, input temperature range of 0 ~ 1000℃, stable within ± 2℃ within 50 mins, can provide 10KW / m²-50KW / m² of radiation exposure.
·The use of mass flow controllers and differential pressure sensors enhances the accuracy of the manometer and enables automatic leak testing.
·The ignitor is equipped with automatic ignition device; flame length 30mm ± 5mm; in accordance with the standard provisions of blue flame with yellow on the top.
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
Smoke Density Measurement System
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
Control System
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
·The printer is optional
·Voltage: 220V; Power 4KW
·Propane gas customer-owned
The main principle of smoke density measurement is that in a particular space, the cable or material produces smoke under specific combustion or radiation conditions, and the light beam penetrating through the smoke will produce attenuation. Measuring the light transmittance and calculation will get the optical density and smoke density.
The instrument is designed and developed according to ISO5659 related standards. With the use of Conical radiation furnace, the heat flux in the chamber can be as high as 50 kW/ m2, and the sample can be positioned horizontally to test the mass loss rate of the sample. This also complies with the latest IMO test terms. Measure the amount of smoke generated when the sample is vertically exposed to a radioactive heat source at 25 kW / m2 when there is or there is no forward flame in confined space.
Using the standard ISO 5659 conical radiant heating furnace, the user can adjust the heating conditions from 10 kW㎡ into 50 kW/㎡ or 70kW/㎡.
Standards
GB/T8323.2-2008: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-1: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-2: Plastics-Smoke generation-Part2: Determination of optical density by a single-chamber test
·The tester consists of a chamber, a sample box, a radiant cone, an igniter, a light transmission and measuring device and other related control devices.
·Ergonomic design and control design; chamber with a fully open door ; door lock designed to facilitate one-time closure of the door; optimize the operation process.
·The test chamber door can be fully opened to facilitate loading and unloading samples and cleaning the box;
·Front door, hinge mounted, with window and non-transparent light shading board which can block the window, to prevent light from entering the sealed chamber.
·The controller is located on the side of the chamber for easy operation. When the door is closed, it does not affect the controller to be viewed.
·Safe flameout board, easy to replace, more secure operation.
·A gas measuring port is available for testing gas toxicity.
·The coating of the test chamber is easy to clean and resistant to chemical corrosion.
Combustion Apparatus
·Heating cone: power 2600W, input temperature range of 0 ~ 1000℃, stable within ± 2℃ within 50 mins, can provide 10KW / m²-50KW / m² of radiation exposure.
·The use of mass flow controllers and differential pressure sensors enhances the accuracy of the manometer and enables automatic leak testing.
·The ignitor is equipped with automatic ignition device; flame length 30mm ± 5mm; in accordance with the standard provisions of blue flame with yellow on the top.
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
Smoke Density Measurement System
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
Control System
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
·The printer is optional
·Voltage: 220V; Power 4KW
·Propane gas customer-owned
Send product request
Other supplier products
| fogging test equipment | Working Principle: The main frame of theFogging Testerincludes a water sink fully filled with specified ethylene glycol, which can reach a high te... | |
| IEC60695 Needle Flame Tester | Standards:GB / T 4207-84, IEC 6112, ASTM D3638, DIN 53480 and UL 746A test methodsScope of application:Needle flame tester used not only for low-vo... | |
| wet penetration textile test instrument | The Wet microbial penetration resistance tester is used to determine the performance of the material in the resistance to the penetration of bacter... | |
| Chrysler Bending Test instruments | Brief IntroductionChrysler bending tester is designed for bending and folding manner by testing base fabric adhesion of the coating material,ie mec... | |
| Dry microbial penetration resistance tester | DryMicrobial Penetration Resistance Testeris designed to determine determine the penetration resistance of material to bacterial on dry particu... |
Same products
| Leather Bursting strength testing machine | Seller: Standard International Group (HK) Limited | Bursting Strength Tester is an intelligent and automatic rupture strength testing machine to test... | |
| Ureaplasma Urealyticum Fluorescent Polymerase Chain Reaction Diagnostic Kit | Seller: Daan Gene Co., Ltd. | Ureaplasma urealyticum is a type of bacteria that can cause infection of the urinary tract and va... | |
| Pathology Test | Seller: Daan Gene Co., Ltd. | What Is Pathology Diagnosis? Pathology is focusing on the nature, cause, origin, and development... | |
| Low Power SPD | Seller: Shanghai Chenzhu Instrument Co., Ltd. | The low voltage surge protection deviceis designed to prevent transient surge conditions. T range... | |
| Intrinsic Isolated Barrier | Seller: Shanghai Chenzhu Instrument Co., Ltd. | Isolated barrier uses intrinsically safe explosion-proof and functional safety technologies and a... |