SKCL-C Rapid concrete chloride tester

Product introduction
Chloride ion is one important factor to induce reinforcement corrosion. In order to avoid premature reinforcement corrosion, chloride ion in the concrete raw material must be controlled very strictly. The related standards in our country have clear requirements to test chloride ion when chooses the raw materials, such as the matching sand, aggregate concrete, cement and admixture, mixing water, fundamentally avoid adding excessive chloride ion into the concrete. The test of the chloride ion content in concrete structure plays a significant role for the evaluation of the structure safety, and provides the extreme reference value basis for the renovation and repair of the old structure at the same time.
The instrument follows the related standards, such as GB/T 50476-2008, JGJ206-2010, JTJ 270-98 and so on.It adopts the ISE (Ion Selective Electrode) method to rapidly test the water soluble chloride ion content of the inorganic material in room temperature, such as concrete, sand , cement, mixing water, by the equipped professional software and anti-interference chemical reagents, to achieve the purposes of prevention and control of premature concrete reinforcement corrosion occurrence.
Feature:
1. Can test the chlorine ion content of concrete mixture, hard concrete, gravel, admixture, water, and the other water-soluble material, directly output the mol concentration and percentage unit results;
2. The built-in standard formula can directly calculate the chloride ion content of concrete mixture
3. Special ion anti-interference agent can remove the oxidation effect of cyanogens and ammonia, and remove the complexation effect of manganese, lead and other metal ion
4. LCD display, instant printing, one key for completing the test, simple operation
5. Light and small, convenient for carrying, suitable for the field detection
6. Optional micro-printer, can also print immediately without computer
7. Unique self-diagnosis function and PC analysis software
8. Great data storage capacity can store 100 test data, data is continuous, safe and reliable
Test object:
Sea sand, ordinary sand, new mixed concrete, hard concrete, cement, stones, and admixture, concrete mixing water and other water-soluble material.
Detection principle:
NJCL-C Rapid concrete chloride tester adopts the ISE (ion selective electrode) method rapidly to test the chlorine ion content of concrete, sandstone, admixture and the other water-soluble matters. The range of chlorine ion concentration is 10-5 ~ 10-1 M mol/L. Operation is simple, and can be used in the field detection, data accurate and rapid, automatic data processing.
Technical parameters:
Operating Voltage: DC 3.6V
Measurement Accuracy: <10%
Data storage capacity: > 100
PC communication parameters: baud rate 2400
Acquisition time: =<3min
Standby time: > 24 hr
Weight: 240 g
LCD Size: 128 * 128
Test procedures:
1. Weigh sample, add an appropriate amount of distilled water or extract liquor
2. Calibrate electrode and test the sample solution
3 print measurement data
Test results:
1 chloride ions Cl ˉ concentration (mol/L)
2 chloride ion content percentage (%)
3 chloride ion content percentage of concrete (%)

Range: 0.0001% ~ 30.00% (Clˉ) ,10-5 ~ 10-1 M( mol/L)
Accuracy: reading +/- 10% (chloride ion)
Operating temperature: 0 centigrade ~ 40 centigrade
Power: 1) 3.6V adapter; 2) lithium battery
Battery Life: 12 months (8 hours per day)

Instrument Specifications:
Host Size: 180 * 70 * 30 (mm)
Weight: 0.4 kg
Host dimension: 370 * 300 * 180 (mm)
Host weight: 5 kg


Send product request

To: Beijing SKE Technology Co.,Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

SKCL-C Rapid concrete chloride tester
SKCL-C Rapid concrete chloride tester Product introduction Chloride ion is one important factor to induce reinforcement corrosion. In order to avoid premature reinforcement corrosion, c...
DJCS-05 Crack Depth measurement instrument
DJCS-05 Crack Depth measurement instrument According to: Technique Regulation of Concrete Defect Detection with Ultrasonic CECS21: 2000 Depth measurement principle When vibration energy tran...
SK-DTL Concrete Resist Chloride Ion penetration tester
SK-DTL Concrete Resist Chloride Ion penetration tester Detection method: electricity Executive Standard Standard for test methods of long-term performance and durability of ordinary concrete(GB/T50082-2...
SKZY-10/20/30 anchor shank tension tester
SKZY-10/20/30 anchor shank tension tester Executive Standard GB50367-2006 Design code for strengthening concrete structure Product introduction: The instrument is suitable for testing the a...
SK225-S digital voice test hammer
SK225-S digital voice test hammer Brief introduction: NJ225-S test hammer submit to standard of GB/T9138-1988 and JJG817-93 and JGJ/T23-2001. Automatically calculate data and on sit...
All supplier products

Same products

Optical Brightener OB-1 (OBA 393)
Optical Brightener OB-1 (OBA 393) Seller: Jinan Ogilvy Chemical Co., Ltd Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo...
PH-A63 Waterproof PH/EC/Temperature Meter
PH-A63 Waterproof PH/EC/Temperature Meter Seller: Kelilong Electron Co.,Ltd Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c...
PH-A6 Waterproof pH and Temperature Meter
PH-A6 Waterproof pH and Temperature Meter Seller: Kelilong Electron Co.,Ltd Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ...
PH-A8 Waterproof Soil PH Meter
PH-A8 Waterproof Soil PH Meter Seller: Kelilong Electron Co.,Ltd Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ...
TH021WIFI Internet of Things TEMP&HUMIDITY Controller
TH021WIFI Internet of Things TEMP&HUMIDITY Controller Seller: Kelilong Electron Co.,Ltd Product description: The electronic thermostat can be used for a variety oftemperature control...