SK225-S digital voice test hammer
Brief introduction:
NJ225-S test hammer submit to standard of GB/T9138-1988 and JJG817-93 and JGJ/T23-2001. Automatically calculate data and on site print test report.
Trait:
1) Big display screen, resolution 160*160 (similar product in market is 160*128)
2) Low power consumption, 2pcs AA battery. (Similar product in market needs 6pcs)
3) Voice report test value, improve efficiency. (Similar product in market no voice)
4) USB interface, convenient in connecting with PC. (Other brand adopts RS232 interface)
5) Easy to operate, the software can set rebound value from upper limit to lower limit, and the abnormal date will be deleted automatically.
6) Important component made from imported materials, after our excellent processing, the instrument get better accuracy and long use life.
Parameters:
Test range: 10~60Mpa
Standard impact energy: 2.207J
Stiffness of tension spring: 785N/M
Stroke of rebound hammer: 75cm
Error range of displayer: ≤±1 (the difference between displayer and scale)
Average rebound value on steel anvil: 80±2
Power source: 2pcs 1.5VVAAA battery
Power consumption: when testing≤50mA, free status, ≤20mA
Storage: 100*50*16=80000 test points.
Send product request
Other supplier products
| SKTJ-10 carbon fiber adhesive strength tester | Executive standard CECS 146:2003 Technical specification for strengthening concrete structures with carbon fiber reinforced polymer laminate Produ... | |
| SK-RCM Rapid Concrete chloride migration tester | Detection method: Electromigration method (RCM) Executive Standard: NT BUILD 492(Chloride Migration Coefficient from Non – Steady - State Mig... | |
| SK-75 brick test hammer | Brief introduction: Submit to standard of GB/T50315-2000, the instrument is applied to test light material such as brick, light bone concrete etc. ... | |
| SKZY-10/20/30 anchor shank tension tester | Executive Standard GB50367-2006 Design code for strengthening concrete structure Product introduction: The instrument is suitable for testing the a... | |
| SK-DTL Concrete Resist Chloride Ion penetration tester | Detection method: electricity Executive Standard Standard for test methods of long-term performance and durability of ordinary concrete(GB/T50082-2... |
Same products
| Optical Brightener OB-1 (OBA 393) | Seller: Jinan Ogilvy Chemical Co., Ltd | Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo... | |
| PH-A63 Waterproof PH/EC/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c... | |
| PH-A6 Waterproof pH and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ... | |
| PH-A8 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ... | |
| TH021WIFI Internet of Things TEMP&HUMIDITY Controller | Seller: Kelilong Electron Co.,Ltd | Product description: The electronic thermostat can be used for a variety oftemperature control... |