Wear Track Profilometer
Applicable standards
When the probe type material surface abrasion measuring instrument is tested, it usually needs to follow certain standards and specifications to ensure the accuracy and comparability of the test results. However, because the specific applicable standards for this device may vary from manufacturer to manufacturer, application field and test needs, a uniform standard cannot be given. In general, however, the following aspects may be applicable:
Equipment calibration and maintenance: Before testing, ensure that the probe type material surface abrasion measuring instrument has been calibrated and is in good working order. At the same time, the equipment should also be regularly maintained and maintained to ensure its long-term stable operation.
Test conditions and methods: According to the specific test requirements and standards, the appropriate test conditions and methods should be selected for testing. This includes selecting the right friction and wear testing machine, abrasive, load, speed and other parameters, as well as ensuring the stability and consistency of the test environment.
Data processing and analysis: After the completion of the test, the test data should be processed and analyzed. This includes calculating parameters such as the depth and width of the abrasion mark, and comparing the test results under different test conditions. At the same time, it can also be combined with other testing means and methods for comprehensive analysis and evaluation.
Main uses
The probe type material surface abrasion measuring instrument is a kind of high precision measuring equipment, its main purpose is to accurately measure and analyze the abrasion marks formed by the friction grinding test on the material surface. Specifically, the main uses of the device include:
Abrasion depth and width measurement: The probe type material surface abrasion measuring instrument can automatically measure the depth and width of the abrasion, providing accurate numerical results. It is of great significance to evaluate the wear resistance of materials, optimize the material design and improve the test conditions of friction and wear.
Wear mark topography analysis: The device can graphically display the two-dimensional outline of the wear mark, and intuitively characterize the wear condition and wear resistance of the material surface. This helps researchers gain a deeper understanding of the mechanisms and processes of friction and wear.
Data storage and report generation: The probe type material surface abrasion meter has a data storage function to save test data for subsequent analysis and comparison. At the same time, the device can also automatically generate test reports, which is convenient for users to organize and archive test results.
Material development and optimization: In the process of material development, the equipment can be used to select materials with excellent wear resistance, providing a scientific basis for material selection and optimization design
Technical parameters
Abrasion scanning method Automatic
Longitudinal resolution of scanning probe 0.02μm
Wear test force range ≦40g
Longitudinal measurement range of scanning probe ±0.5mm (Measurement range can be changed according to the user's requirements)
X-axis travel range 0~50mm
Y-axis travel range 0~25mm
Z-axis travel range 0~50mm
Size of sample tray Φ76mm
Dimensions of the main body of the instrument 230*300*260 Weight of the main body of the instrument (Kg) 10 *260
Weight of main unit (Kg) 10
Send product request
Other supplier products
| Face Mask Tensile Strength Testing Machine (for Face Mask Tensile Tester) | Introduction: The test machine uses the integrated structure of the motor and the speed control system to drive the synchronous belt deceleration ... | |
| Thermostatic water tank tester | Scope of application: Thermostatic water tank is widely used in drying, concentrating, distillation, impregnating chemical reagents, impregnating ... | |
| Helmet Xenon Aging Tester | Standards GB/T2014-9-19. ISO 4892 ASTM G151. G154. D4329 d4587、d4799、sae j2020 Xenon lamp aging test box structure 1. the box is molded by CNC... | |
| Small Parts meter | Test Procedure: Usage Methods and Interpretations Applicable standards: ASTM F963 EN 71-1 16 CFR Part 1501 ISO 8124-1 Product Advantages: Eff... | |
| Automatic Scratch Tester | Product Introduction: It is suitable for printing, labeling, mobile shell, MP3/MP4 shell, laptop computer shell and other kinds of household appl... |
Same products
| FH-77 Dissolved hydrogen meter | Seller: Kelilong Electron Co.,Ltd | Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy... | |
| Xenon Arc Weather Ometer | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... | |
| Plastic Smoke Density Tester F313 | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ... |