Cleanliness Analysis System
The cleanliness analysis system fully complies with the requirements of standards such as VDA19.1 - 2015. ISO16232. ISO4406. ISO4407. QV11111. as well as customer - defined standards. It adopts optical polarization technology and an automatic polarization device. Through a single scan, it can determine the metallic luster reflection properties of all contaminants on the entire filter membrane. Meanwhile, according to the morphological definition of fibers in VDA19.1 (stretching length; maximum inscribed circle diameter > 20. maximum inscribed circle diameter ≤ 50 micrometers), it can automatically complete the classification and size measurement of the following four types of particles within a few minutes: reflective particles, reflective fibers, non - reflective particles, and non - reflective fibers. It can also automatically generate reports based on statistical results (particle size, dimensions, metal, non - metal, fiber).
Compliant standards:
VDA19.IS016232.NAS1638.IS04406
Particle standards:
Built-in 0.1mm/grit and 0.01mm/grit standards for calibration of the instrument scale 56 different particle sizes in the 47mm range from 50-1000um for validation of instrument detection status, particle algorithm, and different brands of instruments. Can be used to validate instrument detection status, particle algorithms, and comparison of measurement capabilities between different brands of instruments Third-party inspection certificates for traceability to national and international standards.
Functional Features:
1. Optical system design allows for simultaneous differentiation between reflective/non - reflective particles with a single scan, enabling uninterrupted scanning.
2. All - electric hardware design with full - process automatic focusing, automatic objective lens switching, and automatic scanning of the overview map, minimizing manual operations to the greatest extent.
3. A simple operation interface with large - button design, making it convenient to operate with a touch screen and streamlining operation steps as much as possible.
4. Built - in database management system, eliminating the need to save the filter membrane.
5. Optional high - magnification objective lenses can identify extremely small particles with a minimum diameter of 2.5μm and observe their appearance at up to 100 - times magnification.
6. Supports industry - common standards such as ISO16232. ISO4406. VDA, and allows for easy customization of standards.
Motorized Scanning Platform:
Scanning range: 125 * 75mm Step accuracy: 1um Repeatability: 5um
Image Acquisition System:
USB3.0 interface to meet the rapid transmission of dynamic images 3 megapixel imported camera Resolution: 2046 * 1544. 53 frames per second, suitable for collecting Dynamic image Global shutter, there will be no shutter curtain shutter common image drag
Energy digital lighting system (ZL technology):
software control and manual control of two modes digital display, light source brightness can be quantified, the test results can be reproduced can be distinguished between metallic and non-metallic particles (according to IS. VDA19.1-2015 specification requirements) Relying on the technology, the film only need to scan once, the analysis speed increased by 50% can be used to analyze the image of the film. 50% faster analysis for automotive parts cleanliness, oil cleanliness testing, parts cleanliness testing, machinery and equipment cleanliness testing
Send product request
Other supplier products
| Plastic ball indentation hardness tester | Meet the standard: JTG E50 T1143-2006.SL/T.JT/T 521- Appendix A-2004.JTS-206-1- Appendix B B.3-2009 JTS/T245-2023.etc. Instrument features: Cus... | |
| Safety Helmets Impact and Penetration Resistance Tester | Standard GB/T 2811-2019(China’s national standard for helmet safety and impact resistance) GB/T 2812-2006/XXXX(Testing methods for impact... | |
| In-situ expansion analysis system | The In-situ Expansion Analysis System is designed for high-precision measurement of dimensional and volumetric changes in electrochemical cells and... | |
| Electrode tortuosity tester & diaphragm ion conductivity tester | The Electrode Tortuosity Tester and Diaphragm Ion Conductivity Tester are precision systems designed for advanced analysis of battery electrodes an... | |
| Catheter Flexibility Tester | The Catheter Flexibility Tester utilizes a control system combining a PLC and an industrial computer, along with a color touch screen interface. It... |
Same products
| Xenon Test Chamber | Seller: Standard International Group (HK) Limited | Features and Benefits 1.The use of xenon arc lamp as a light source, can simulate the full sunli... | |
| Single Cable Vertical Flame Tester | Seller: Qinsun Instruments Co., LTD | Introduction Single Cable Vertical Flame Tester is used for the vertical flame propagation of a ... | |
| Safety Helmet Flammability Tester | Seller: Qinsun Instruments Co., LTD | Product Introduction: Safety hat flame retardant performance tester for safety hat flame retarda... | |
| Furniture flammability tester | Seller: Qinsun Instruments Co., LTD | Product details Furniture flammability tester is mainly used to test the combustion performance ... | |
| Flame retardant testing machine | Seller: Qinsun Instruments Co., LTD | Feature highlights: Flame Retardant Tester is designed for testing plastic runway surface layers... |