Fireproof coatings tester

Sample making:

1. The test plate of the fireproof coating tester (small chamber method) is made of birch five-layer plywood conforming to GB738-75 "broadleaf wood plywood", its size is 300mmx150mmx5mm, and the surface of the sample should be smooth and smooth, without joints and other defects.

2. before the test board is coated with fireproof paint, the state should be adjusted to constant at the temperature of 25±1℃ and the relative humidity of 60%——70% (the weight change of 24h interval is not more than 0.1%)。

3. according to the coating ratio of 200——250g/m2 (thick paste coating allows to increase to 500g/m2) to test the fire retardant coating evenly covered on the surface of the test plate and around, when the need for multiple coating, the interval between two times should be 24h.

The finished specimens shall be adjusted to constant weight according to the condition state specified in 2 articles, and ten specimens of each fireproof coating shall be prepared.

Technical parameters:

The specimen holder can be tilted 450±20

Copper combustion cup: Outer diameter 24mm± 0.1mm,

The wall thickness is 1mm±0.06mm, the height is 17mm±0.1mm and the volume is 6mL

Fuel: Chemically pure grade anhydrous ethanol


Send product request

To: Qinsun Instruments Co., LTD
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Micro Rapid Closed Cup Flash Point Tester(Pensky Martens)
Micro Rapid Closed Cup Flash Point Tester(Pensky Martens) Reference Standards: SN/T 3077.1、SN/T 3077.2. SH/T 0768. DL/T 1354. ASTM D93、ASTM D6450、ASTM D3828、ASTM D7094、ASTM D7236、ASTM D56、ASTM D56、ASTM...
Helmet Strap Tensile Tester
Helmet Strap Tensile Tester Purpose Apply a certain initial load to the helmet strap system for a certain period of time. Then, let a weight of a certain mass fall from a cer...
Catheter Leakage and Compliance Tester
Catheter Leakage and Compliance Tester Standards YY/T, etc. Main Uses The catheter leakage and compliance tester is mainly used to detect the leakage and compliance of medical catheters ...
Compression Test device
Compression Test device TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by artisans and professionals when judging a fabric' s ...
Cleanliness Analysis System
Cleanliness Analysis System Production: The cleanliness analysis system fully complies with the requirements of standards such as VDA19.1 - 2015. ISO16232. ISO4406. ISO4407. ...
All supplier products

Same products

Custom Stainless Components for OEM Applications
Custom Stainless Components for OEM Applications Seller: Yongjia County Yaokang Technology Co., Ltd. Our stainless steel float balls are designed for float valves, water tanks, and industrial liquid...
FH-77 Dissolved hydrogen meter
FH-77 Dissolved hydrogen meter Seller: Kelilong Electron Co.,Ltd Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy...
Xenon Arc Weather Ometer
Xenon Arc Weather Ometer Seller: Standard International Group (HK) Limited Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ...
Xenotest | Light Fastness Tester Si220 (SunTest)
Xenotest | Light Fastness Tester Si220 (SunTest) Seller: Standard International Group (HK) Limited Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ...
Ozone Aging Chamber
Ozone Aging Chamber Seller: Standard International Group (HK) Limited Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum...