Precision thermal conductivity tester for R&D and quality control

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:

Thermal insulation materials

Plastics and polymer-based materials

Rubber and elastomer materials

Aerogel panels and advanced insulation boards

Vacuum glass and building energy-saving materials

Solid materials and powder materials (with appropriate sample configuration)

The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.

Standards

The instrument is designed and operated in accordance with the following international and national standards:

GB/T 10295-2008

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method

ASTM E1530

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM C518-04

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Parameters

ItemSpecification
Thermal conductivity range (low range) 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K)
Thermal conductivity range (extended) 0.001 – 300 W/m·K
Measurement accuracy ±1%
Sample size 50 × 50 to 300 × 300 mm
Maximum sample thickness ≤ 50 mm
Optional sample sizes 600 × 600 mm, 800 × 600 mm (customized)
Applicable sample form Solid materials, powder materials
Test duration 15 – 20 min
Hot plate temperature range Room temperature to 99.9 °C (standard)
Optional hot plate range Room temperature to 499.9 °C or higher (by agreement)
Hot plate control accuracy 0.1 °C
Cold plate temperature range 0 – 99.9 °C (standard); –10 – 99.9 °C optional
Cold plate temperature control Water-cooled, precision constant-temperature bath
Cold plate control accuracy 0.1 °C
Pressure range 0 – 1000 N
Pressure resolution 0.1 N
Thickness measurement range 0 – 50 mm
Thickness resolution 0.1 μm
Heat flow sensor Imported original heat flow meter
Test operation Fully automatic computer-controlled testing and data storage
Power supply AC 220 V / 50 Hz

Test Procedures

Prepare the specimen according to size and thickness requirements.

Place the specimen between the hot plate and cold plate.

Set the target hot-side and cold-side temperatures in the software.

Apply pressure automatically to ensure stable contact.

Allow the system to reach steady-state heat transfer conditions.

Measure the heat flux and temperature gradient across the specimen.

Calculate thermal conductivity and thermal resistance automatically.

Save and print test data and reports.

Maintenance Information

Keep hot and cold plate surfaces clean and undamaged

Ensure proper operation of the constant-temperature water bath

Periodically check sensor performance and calibration status

Maintain stable laboratory environmental conditions during testing

Store reference samples and accessories properly when not in use


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Automatic Liquid Dosing System for Textile Color Fastness ISO & AATCC Standards Manufacturer Direct
Automatic Liquid Dosing System for Textile Color Fastness ISO & AATCC Standards Manufacturer Direct Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features User-friendly interface: Color touch screen with intuitive human-ma...
Coating thickness gauge/film thickness gauge
Coating thickness gauge/film thickness gauge Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard Coating Thickness Gauge complies with international standards includingASTM B499,...
Flame Spread Index Tester | Fire Spread & Surface Burning Test Equipment Manufacturer
Flame Spread Index Tester | Fire Spread & Surface Burning Test Equipment Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Parameters ParameterSpecification Dimensions 950 × 600 &ti...
Micro-hole Detection Instrument
Micro-hole Detection Instrument Whats/App: +86 156 1874 6768 Web: standard-groups.com The pinhole tester for aluminum foil is a device specifically used to detect micro - pinhol...
Syringe Sealing Negative Pressure Tester
Syringe Sealing Negative Pressure Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Syringe Sealing Negative Pressure Tester is a precision instrument designed to evaluate...
Все товары поставщика

Похожие товары

Laser Cutting Machines
Laser Cutting Machines Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 Продавец: 868983 Common Rail Injector Valve F00R J02 012 David Chen