Precision thermal conductivity tester for R&D and quality control

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:

Thermal insulation materials

Plastics and polymer-based materials

Rubber and elastomer materials

Aerogel panels and advanced insulation boards

Vacuum glass and building energy-saving materials

Solid materials and powder materials (with appropriate sample configuration)

The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.

Standards

The instrument is designed and operated in accordance with the following international and national standards:

GB/T 10295-2008

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method

ASTM E1530

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM C518-04

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Parameters

ItemSpecification
Thermal conductivity range (low range) 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K)
Thermal conductivity range (extended) 0.001 – 300 W/m·K
Measurement accuracy ±1%
Sample size 50 × 50 to 300 × 300 mm
Maximum sample thickness ≤ 50 mm
Optional sample sizes 600 × 600 mm, 800 × 600 mm (customized)
Applicable sample form Solid materials, powder materials
Test duration 15 – 20 min
Hot plate temperature range Room temperature to 99.9 °C (standard)
Optional hot plate range Room temperature to 499.9 °C or higher (by agreement)
Hot plate control accuracy 0.1 °C
Cold plate temperature range 0 – 99.9 °C (standard); –10 – 99.9 °C optional
Cold plate temperature control Water-cooled, precision constant-temperature bath
Cold plate control accuracy 0.1 °C
Pressure range 0 – 1000 N
Pressure resolution 0.1 N
Thickness measurement range 0 – 50 mm
Thickness resolution 0.1 μm
Heat flow sensor Imported original heat flow meter
Test operation Fully automatic computer-controlled testing and data storage
Power supply AC 220 V / 50 Hz

Test Procedures

Prepare the specimen according to size and thickness requirements.

Place the specimen between the hot plate and cold plate.

Set the target hot-side and cold-side temperatures in the software.

Apply pressure automatically to ensure stable contact.

Allow the system to reach steady-state heat transfer conditions.

Measure the heat flux and temperature gradient across the specimen.

Calculate thermal conductivity and thermal resistance automatically.

Save and print test data and reports.

Maintenance Information

Keep hot and cold plate surfaces clean and undamaged

Ensure proper operation of the constant-temperature water bath

Periodically check sensor performance and calibration status

Maintain stable laboratory environmental conditions during testing

Store reference samples and accessories properly when not in use


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Mar resistance tester for plastic and automotive parts
Mar resistance tester for plastic and automotive parts Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards This tester is suitable for testing according to: (1) GM 9150P – Scratch ...
Vacuum Cleaner Simulated Walking Life Tester
Vacuum Cleaner Simulated Walking Life Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com TheVacuum Cleaner Simulated Walking Life Testeris designed for long-term life-cycle aging a...
CE certified mask fit tester
CE certified mask fit tester Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Qinsun PortaCount Respirator Fit Tester assesses the overall integrity of...
Safety Helmets Against Molten Metal Splashing Tester
Safety Helmets Against Molten Metal Splashing Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2812-XXXX: Safety Helmets – Test Methods for Molten Metal Resistance (...
Large Walk-in Aging Chamber Manufacturer | IEC 60068 Thermal Aging Testing Solutions
Large Walk-in Aging Chamber Manufacturer | IEC 60068 Thermal Aging Testing Solutions Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This equipment is suitable for environmental aging and reliabili...
All supplier products

Same products

ER4047 Aluminum Mig Welding Wire
ER4047 Aluminum Mig Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing reliable welding material...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate...
Choosing the Right Equipment for Heavy-Duty Cleaning
Choosing the Right Equipment for Heavy-Duty Cleaning Seller: Taizhou Feike Mechanical Technology Co., Ltd. FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...