Precision thermal conductivity tester for R&D and quality control
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:
Thermal insulation materials
Plastics and polymer-based materials
Rubber and elastomer materials
Aerogel panels and advanced insulation boards
Vacuum glass and building energy-saving materials
Solid materials and powder materials (with appropriate sample configuration)
The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.
Standards
The instrument is designed and operated in accordance with the following international and national standards:
GB/T 10295-2008
Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method
ASTM E1530
Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique
ASTM C518-04
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Parameters
| Item | Specification |
|---|---|
| Thermal conductivity range (low range) | 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K) |
| Thermal conductivity range (extended) | 0.001 – 300 W/m·K |
| Measurement accuracy | ±1% |
| Sample size | 50 × 50 to 300 × 300 mm |
| Maximum sample thickness | ≤ 50 mm |
| Optional sample sizes | 600 × 600 mm, 800 × 600 mm (customized) |
| Applicable sample form | Solid materials, powder materials |
| Test duration | 15 – 20 min |
| Hot plate temperature range | Room temperature to 99.9 °C (standard) |
| Optional hot plate range | Room temperature to 499.9 °C or higher (by agreement) |
| Hot plate control accuracy | 0.1 °C |
| Cold plate temperature range | 0 – 99.9 °C (standard); –10 – 99.9 °C optional |
| Cold plate temperature control | Water-cooled, precision constant-temperature bath |
| Cold plate control accuracy | 0.1 °C |
| Pressure range | 0 – 1000 N |
| Pressure resolution | 0.1 N |
| Thickness measurement range | 0 – 50 mm |
| Thickness resolution | 0.1 μm |
| Heat flow sensor | Imported original heat flow meter |
| Test operation | Fully automatic computer-controlled testing and data storage |
| Power supply | AC 220 V / 50 Hz |
Test Procedures
Prepare the specimen according to size and thickness requirements.
Place the specimen between the hot plate and cold plate.
Set the target hot-side and cold-side temperatures in the software.
Apply pressure automatically to ensure stable contact.
Allow the system to reach steady-state heat transfer conditions.
Measure the heat flux and temperature gradient across the specimen.
Calculate thermal conductivity and thermal resistance automatically.
Save and print test data and reports.
Maintenance Information
Keep hot and cold plate surfaces clean and undamaged
Ensure proper operation of the constant-temperature water bath
Periodically check sensor performance and calibration status
Maintain stable laboratory environmental conditions during testing
Store reference samples and accessories properly when not in use
在线联系供应商
Other supplier products
| Contact heating and cooling test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com The sensation of coldness or warmth when skin touches a fabric is referred to as the "coldn... | |
| Material friction stick slip testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Stick-Slip Tribological Test Stand is a laboratory testing system used to evaluate fric... | |
| Bio-absorbable Internal Fixation Plates and Screws Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bio-absorbable Internal Fixation Plates and Screws Tester is a specialized mechanical t... | |
| Particle Strength Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Particle Strength Tester is a high-precision instrument designed to measure the mechani... | |
| Safety Helmets Acceleration Impact & Penetration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2812: Safety Helmets (China National Standard) Equivalent Compliance: ISO 6... |
Same products
| ER4047 Aluminum Mig Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing reliable welding material... | |
| ER4043 Silicon Aluminum Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate... | |
| Choosing the Right Equipment for Heavy-Duty Cleaning | 卖方: Taizhou Feike Mechanical Technology Co., Ltd. | FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve... | |
| ER4043 Silicon Aluminum Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin... | |
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... |