Breathing simulator manikin

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)

GB/T 18883-2022 — Indoor Air Quality Standard

ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort

ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement

Product Specifications

ComponentTechnical Parameters
Breathing Function Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request
Exhalation Volume Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar
Breathing Mode Switchable nasal breathing or oral breathing (when used with a thermal manikin)
Exhaled Airflow Equipped with heating module; airflow temperature adjustable from 34 to 36 °C
Sampling Branch Main breathing line includes a sampling port for aerosol or pollutant sampling
Electrical Control System Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W
Operating Environment Temperature 10–40 °C; humidity 15–95%
Others Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg

Features

Accurate simulation of human breathing cycles and airflow parameters, with support for customized breathing functions;

Adjustable exhalation temperature to ensure experimental conditions are close to real human breathing;

Compatible with a 16-zone thermal manikin to simulate interaction between body heat sources and breathing airflow;

Modular design allowing independent use or localized experiments on specific body parts;

High-sensitivity airflow control components with millisecond-level response, using imported components from Germany;

Comprehensive safety protection, including over-pressure protection, short-circuit protection, and lockable caster wheels.

Accessories

Accessory / ConsumableSpecification
Breathing Control Cabinet Includes PID control, pressure gauges, and flow display modules
Heating Module Exhaled air heating module with adjustable temperature from 34 to 36 °C
Main Breathing Line Equipped with sampling branch for aerosol or pollutant sampling devices
Quick-Connect Cables For connection to thermal manikin or head model, easy installation and removal
Customizable Modules Nasal or oral breathing interfaces; child or infant manikin compatible modules

Test Principle

The manikin breathing system simulates a sinusoidal human breathing cycle by controlling inhalation and exhalation flow rate, pressure, and temperature. When combined with a thermal manikin, the system generates thermal airflow patterns and air distribution similar to those of the human body. Under controlled experimental conditions, you can collect data on particle concentration, gaseous pollutant distribution, and airflow behavior. These data are used for breathing exposure assessment, airborne disease research, and indoor airflow field analysis.

Operation Instructions

Confirm that the ambient temperature is 10–40 °C and relative humidity is 15–95% before installation;

Ensure power supply is AC 220 V / 50 Hz, with total power ≤ 350 W and exhaled air heating module power ≤ 1000 W;

Connect the breathing system to the thermal manikin using quick-connect interfaces and check cable integrity;

Set breathing parameters such as frequency, volume, inhalation/exhalation timing, and breathing mode, with PID parameters automatically tuned;

Switch between nasal and oral breathing modes during testing as required by the exposure scenario;

When using the sampling branch, ensure aerosol sampling devices are properly connected to avoid air leakage;

After testing, switch off the system, save data, and disconnect all connections.

Test Procedure

Connect the breathing system to the thermal manikin or head model and check all cables and interfaces;

Power on the control system and set breathing parameters and airflow temperature;

Activate the heating module and wait until exhaled air temperature stabilizes;

Select nasal or oral breathing mode according to test requirements;

Start the experiment and record breathing pressure, flow rate, temperature, and particle distribution data in real time;

After completion, shut down the system, disconnect power, and clean sampling ports and pipelines.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Femoral Stem Fatigue Performance Testing Machine
Femoral Stem Fatigue Performance Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in par...
Oil Filter Hydrostatic Breakage Tester,Automotive Oil Filter Hydraulic Pressure Tester
Oil Filter Hydrostatic Breakage Tester,Automotive Oil Filter Hydraulic Pressure Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Oil Filter Hydrostatic Breakage Tester operates by using a liquid medium (typically hyd...
Portable Retroreflectometer for Wet and Dry Conditions ASTM E2177
Portable Retroreflectometer for Wet and Dry Conditions ASTM E2177 Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The machine complies with multiple international and national stan...
Dry Sand Rubber Wheel Wear Tester
Dry Sand Rubber Wheel Wear Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The dry sand rubber wheel abrasion tester is mainly used to test the abrasion resistance of...
Laboratory and industrial friction and wear tester
Laboratory and industrial friction and wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Materials science research: Evaluation of friction and wear behavior of metals...
Все товары поставщика

Похожие товары

Laser Chuck
Laser Chuck Продавец: 00000 Laser Chuck Introduce foreign advanced technology and management concept, High precision pro...
Power Pallet Jack For Sale
Power Pallet Jack For Sale Продавец: Jinan Hulk Machinery Co., Ltd Power Pallet Jack For Sale Electric Pallet Truck For Sale As a supplier of power pallet jac...
Multi Directional Forklift For Sale
Multi Directional Forklift For Sale Продавец: Jinan Hulk Machinery Co., Ltd Multi Directional Forklift For Sale Multi Directional Forklift For Sale As a supplier of mu...
Narrow Aisle Forklift For Sale
Narrow Aisle Forklift For Sale Продавец: Jinan Hulk Machinery Co., Ltd Narrow Aisle Forklift For Sale Narrow Aisle Forklift For Sale As a supplier of , we provide...
Electric Order Picker Supplier
Electric Order Picker Supplier Продавец: Jinan Hulk Machinery Co., Ltd Electric Order Picker Supplier Electric Order Picker Supplier As an supplier, we offer a co...