Breathing simulator manikin
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)
GB/T 18883-2022 — Indoor Air Quality Standard
ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort
ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement
Product Specifications
| Component | Technical Parameters |
|---|---|
| Breathing Function | Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request |
| Exhalation Volume | Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar |
| Breathing Mode | Switchable nasal breathing or oral breathing (when used with a thermal manikin) |
| Exhaled Airflow | Equipped with heating module; airflow temperature adjustable from 34 to 36 °C |
| Sampling Branch | Main breathing line includes a sampling port for aerosol or pollutant sampling |
| Electrical Control System | Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W |
| Operating Environment | Temperature 10–40 °C; humidity 15–95% |
| Others | Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg |
Features
Accurate simulation of human breathing cycles and airflow parameters, with support for customized breathing functions;
Adjustable exhalation temperature to ensure experimental conditions are close to real human breathing;
Compatible with a 16-zone thermal manikin to simulate interaction between body heat sources and breathing airflow;
Modular design allowing independent use or localized experiments on specific body parts;
High-sensitivity airflow control components with millisecond-level response, using imported components from Germany;
Comprehensive safety protection, including over-pressure protection, short-circuit protection, and lockable caster wheels.
Accessories
| Accessory / Consumable | Specification |
|---|---|
| Breathing Control Cabinet | Includes PID control, pressure gauges, and flow display modules |
| Heating Module | Exhaled air heating module with adjustable temperature from 34 to 36 °C |
| Main Breathing Line | Equipped with sampling branch for aerosol or pollutant sampling devices |
| Quick-Connect Cables | For connection to thermal manikin or head model, easy installation and removal |
| Customizable Modules | Nasal or oral breathing interfaces; child or infant manikin compatible modules |
Test Principle
The manikin breathing system simulates a sinusoidal human breathing cycle by controlling inhalation and exhalation flow rate, pressure, and temperature. When combined with a thermal manikin, the system generates thermal airflow patterns and air distribution similar to those of the human body. Under controlled experimental conditions, you can collect data on particle concentration, gaseous pollutant distribution, and airflow behavior. These data are used for breathing exposure assessment, airborne disease research, and indoor airflow field analysis.
Operation Instructions
Confirm that the ambient temperature is 10–40 °C and relative humidity is 15–95% before installation;
Ensure power supply is AC 220 V / 50 Hz, with total power ≤ 350 W and exhaled air heating module power ≤ 1000 W;
Connect the breathing system to the thermal manikin using quick-connect interfaces and check cable integrity;
Set breathing parameters such as frequency, volume, inhalation/exhalation timing, and breathing mode, with PID parameters automatically tuned;
Switch between nasal and oral breathing modes during testing as required by the exposure scenario;
When using the sampling branch, ensure aerosol sampling devices are properly connected to avoid air leakage;
After testing, switch off the system, save data, and disconnect all connections.
Test Procedure
Connect the breathing system to the thermal manikin or head model and check all cables and interfaces;
Power on the control system and set breathing parameters and airflow temperature;
Activate the heating module and wait until exhaled air temperature stabilizes;
Select nasal or oral breathing mode according to test requirements;
Start the experiment and record breathing pressure, flow rate, temperature, and particle distribution data in real time;
After completion, shut down the system, disconnect power, and clean sampling ports and pipelines.
Send product request
Other supplier products
| Powder Wet Vibrating Screen System For Lithium Battery Material Testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM E11: Standard Specification for Woven Wire Test Sieve Cloth and Test Sieve... | |
| Flexible Container Integrity Tester | ISO 11607 Seal Integrity Testing Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Testing flexible packaging for food, pharmaceuticals, and consum... | |
| Carpet Flammability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheCarpet Flammability Testeris designed to assess the flame-retardant properties of textil... | |
| Mobile Floor Scrubber Aging Life Test Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheMobile Floor Scrubber Aging Life Test Equipmentis designed to evaluate the long-term dur... | |
| ISO 4892 Tabletop Xenon Arc Weathering Tester SunMaster Manufacturer China | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards This instrument fully complies with and supports multiple stringen... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |













