Leakage negative pressure tester for infusion device

Leakage negative pressure tester for infusion device - Other test instrument - standard


Product Information:

The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard(gb838-2005) designed to detect the sealing performance of the infusion device.

Technical Parameters:
1、environment:
operating temperature:5~40℃
relative humidity:(45~80)%
Power voltage:220V±22V
Grid frequency:50HZ±1HZ
2、Specification
Negative pressure test: -10 ~ -30kpa error is not greater than + 0.5KPa, LED digital display negative pressure.
Negative pressure output -10 ~ -30kpa + 0.5kpa, LED digital display negative pressure.
The negative pressure of the measuring system is maintained: within 1 minute, it shall not drift + 0.5kpa.
Duration of test: 60S, no more than 0.5KPa.

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Upper Leather Flexing Tester
Upper Leather Flexing Tester Main uses: VAMP VAMP leather extension testing machine with a certain frequency of zigzag test, observe the change of the surface of the test piec...
Glove Cut Resistance Tester
Glove Cut Resistance Tester Product Introduction: The machine is used to test the cutting resistance of gloves. Under the specified load, the blade cuts the sample to measure...
Whole Shoes Flexing Tester
Whole Shoes Flexing Tester Applications: Shoes Flexing Tester determine its flexibility resistance of shoes or shoes sole through reciprocating flexing movements under the...
Oxidizing Solids Tester/ Reactive Solid Material Tester/ Solid Oxidizer Tester
Oxidizing Solids Tester/ Reactive Solid Material Tester/ Solid Oxidizer Tester Product Description Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria 34.4.1 Test O.1: Test for ...
Double Plate Thermal Conductivity Apparatus
Double Plate Thermal Conductivity Apparatus Standards: GB/T 10294-2008 ?Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials GB/T 3399-19...
All supplier products

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Seller: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Seller: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Seller: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Seller: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Seller: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...