Leakage negative pressure tester for infusion device
Leakage negative pressure tester for infusion device - Other test instrument - standard
Product Information:
The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard(gb838-2005) designed to detect the sealing performance of the infusion device.
Technical Parameters:
1、environment:
operating temperature:5~40℃
relative humidity:(45~80)%
Power voltage:220V±22V
Grid frequency:50HZ±1HZ
2、Specification:
Negative pressure test: -10 ~ -30kpa error is not greater than + 0.5KPa, LED digital display negative pressure.
Negative pressure output -10 ~ -30kpa + 0.5kpa, LED digital display negative pressure.
The negative pressure of the measuring system is maintained: within 1 minute, it shall not drift + 0.5kpa.
Duration of test: 60S, no more than 0.5KPa.
Send product request
Other supplier products
| ROSS zigzag tester | Product Introduction: The ROSS zigzag resistance tester installed the sole strip test piece on the ROSS zigzag test machine, so that the cut is di... | |
| Pump and Valve Contamination Tolerance Tester | Meet the standard: ISO 4406 ISO 18413 ISO 10707 ISO 6403 ISO 10372 NFPA T2.6.1 Product Introduction: Solid particle contamination is a major... | |
| Ignition Distance Tester for Aerosol Sprays | Product Information: 1. It adopts an embedded processor and the Windows CE operating system. 2. With an 8 - inch liquid - crystal touch screen,... | |
| Sweating Guarded Hotplate/ Thermal Insulation and Moisture Permeability Tester / Fabric Thermal Resistance Tester | Testing Standards:GB/T 11048, ISO 11092, ASTM F1868, ASTM D1518, JIS L1096 Application The Thermal resistance wet resistance tester simulates t... | |
| Stain resistance tester for architectural coatings | Product Introduction: The interior wall coating in architectural coatings is often polluted by some pollution from daily necessities, people often... |
Same products
| Briefly describe the importance, core functionality and how to implement a hospital clock system solution | Seller: California Triangle | In the healthcare industry, precise time synchronization is critical. Every second can be a matte... | |
| Sand and Dust Test Chamber for Automotive Connectors | Seller: Standard International Group (HK) Limited | Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour... | |
| Automotive Connector SO₂/H₂S Corrosion Test Chamber | Seller: Standard International Group (HK) Limited | Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio... | |
| Automotive Connectors Salt Spray Tester | Seller: Standard International Group (HK) Limited | Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117... | |
| Air - tightness Testing Device for Automotive Connectors | Seller: Standard International Group (HK) Limited | Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes... |