SI-111 infrared surface temperature sensor
SI-111 consists of a thermopile and a thermistor. The thermopile measures the surface temperature and the thermistor measures the body temperature of the sensor. The two temperature probes are enclosed in a durable aluminum housing with a germanium optical window on the top. Compared with the silicon optical window, the germanium window is more convenient to correct the target blackness, reduce the influence of atmospheric humidity, and make the sensor and the target object have a longer distance. Both the thermopile and thermistor outputs are millivolt signals. Our data collector can measure the millivolt voltage signal and apply the Stefan-Boltzman equation to correct the effect of the sensor body temperature on the target temperature. Using the Stefan-Boltzman equation, the SI-111 can obtain an absolute accuracy of ±0.2°C between -10 and 65°C.
Technical Parameters
parameter
SI-111
SI-121
Output
60 μV per °C
40 μV per °C
0~2500mV
0~2500mV
angle
22 degrees
18 degrees
measurement accuracy
-10 to 65 °C
±0.2 °C absolute accuracy
±0.1 °C average accuracy
±0.05 °C repeatability
measurement accuracy
-40 to 70 °C
±0.5 °C absolute accuracy
±0.3 °C average accuracy
±0.1 °C repeatability
Wavelength range
8~14μm
Response time
Less than 1 second
Input voltage
2.5V excitation
Operating environment
-55 to 80 °C; 0 to 100% RH
cable length
4.5 meters
Channel required
1 differential + 1 single-ended
size
6cm×2.3cm
weight
190g
Origin: United States
Send product request
Other supplier products
MPS-2 soil water potential sensor | The MPS-2 soil water potential sensor can be easily inserted into the soil profile pit and wrapped with wet soil around it. Measurement and recordi... | |
QT-1000/50 Double tipping bucket flowmeter | Product description: Surface runoffis the flow of water that occurs when excesswaterfromrain,meltwater, or other sources flows over theearth's surf... | |
PONSEL TURBIDITY turbidity sensor | The measuring principle of this sensor is based on IR infrared turbidimetry / 880 nm (ISO 7027). Calibration is performed with formazine standard s... | |
CS471 bubble water level sensor | CS471 bubble water level sensorCS471 is a high-precision (±0.02ft) bubble that is widely used in surface and groundwater level measurement. ... | |
QT-1010-P Evaporation pan | Product description: This evaporation pan can be used for QT-1010 evaporation station. QT-1010-P Evaporation pan Features 1、 Wooden platform 2、 Sta... |
Same products
CLOTH TAPE | Seller: Changzhou Egret Manufacturing Co., Ltd. | Wholesale Cloth Tape Egret electronicscloth tape is also called duct tape. From the name, can te... | |
ALUMINUM FOIL TAPE | Seller: Changzhou Egret Manufacturing Co., Ltd. | ALUMINUM FOIL TAPE Egret aluminum foil tape is our main & strongest products. Our aluminum t... | |
CT/X-Ray Contrast Media | Seller: Beijing Beilu Pharmaceutical Co., Ltd | The main component of CT/X-ray Contrast Media is iodine. The Iodinated Contrast Media is a colorl... | |
Contrast Media Manufacturing Company | Seller: Beijing Beilu Pharmaceutical Co., Ltd | For the purpose of medical imaging, a certain substance is introduced into the human body to chan... | |
Biodegradation Recycled Plastic Extruder Machine | Seller: Nanjing KY Chemical Machinery Co., Ltd. | Biodegradable plastics refer to a kind of plastic that is degraded by natural microorganisms such... |