.

Steel Pipe Testing

Steel having a hollow section that is much longer than the diameter or circumference. According to the cross-sectional shape, it is divided into round, square, rectangular and special-shaped steel pipes; it is divided into carbon structural steel pipe, low-alloy structural steel pipe, alloy steel pipe and composite steel pipe according to the material; it is divided into conveying pipeline and engineering structure according to the purpose. For thermal equipment, petrochemical industry, machinery manufacturing, geological drilling, steel pipes for high-pressure equipment, etc.; according to the production process, it is divided into seamless steel pipes and welded steel pipes, of which seamless steel pipes are divided into hot rolling and cold rolling (pulling). Two kinds of welded steel pipes are divided into straight seam welded steel pipes and spiral seam welded steel pipes.

As an ultrasonic flaw detector manufacturer and supplier, we have been committed to developing and manufacturing high-quality and high-performance NDT equipment to provide customers with the best quality service.

Wireless Transmission Pipe Ultrasonic Flaw Detector

The system is suitable for automatic detection of various internal and external defects of steel pipes. The principle of ultrasonic flaw detection is that after the ultrasonic wave is coupled into the...

LEARN MORE >

Wireless Transmission Pipe Ultrasonic Flaw Detector

Ultrasonic flaw detection mainly includes two methods: penetration flaw detection and reflection method. Penetration testing uses two probes, one for transmitting ultrasound and one for receiving ultrasound. During the inspection, the two probes are placed on both sides of the workpiece, and the internal quality of the workpiece is determined according to the change of energy after the ultrasonic wave penetrates the workpiece. The high-frequency pulse excitation signal generated by the reflection method is applied to the probe, and the generated wave propagates to the inside of the workpiece. If there is a defect inside the workpiece, a part of the wave is reflected back as a defect wave. The bottom wave will also reflect back. According to the position of the emitted wave, the defect wave and the bottom wave relative to the scanning baseline, the defect position can be determined; the size of the defect can be determined according to the amplitude of the defect wave; the nature of the defect can be analyzed according to the shape of the defect wave; if there is no defect inside the workpiece, only launch wave and bottom wave.

In the process of flaw detection, it is first necessary to understand the technical requirements of the drawings for welding quality. The acceptance criteria for steel structures are implemented in accordance with GB50205-2001 "Code for Acceptance of Construction Quality of Steel Structures". The standard stipulates that for the drawings, the weld quality of the weld is required to be level 1 and the level of the weld is rated as Class II, and the 100% ultrasonic flaw detection is required. For the drawings, the weld weld quality grade is Grade II, and the grade is Grade III. It is required to do 20% ultrasonic flaw detection; for the drawings, the weld quality of the weld is required to be level 3 and no ultrasonic internal defect inspection is performed.

It is worth noting here that ultrasonic flaw detection is used for full penetration welds, and the flaw detection ratio is calculated as a percentage of the length of each weld and is not less than 200 mm. Weld for local flaw detection.

If it is found that there is an impermissible defect, the length of the flaw detection shall be increased at the extension of the two ends of the defect. The length shall not be less than 10% of the length of the weld and shall not be less than 200 mm. When there are still impermissible defects, the weld is subjected to a 100% inspection of the flaw. In addition, the thickness of the base material to be tested, the joint type and the groove type should be known. Generally, the thickness of the base metal is between 8 and 16 mm, and the groove type has several forms such as type I, single V type and X type. After you have figured out this thing, you can prepare for the flaw detection.

The standard test block (CSK-IA, CSK-IIIA) must be used to calibrate the overall performance of the ultrasonic pipe testing equipment before each inspection operation, and the panel curve is calibrated to ensure the accuracy of the flaw detection results.

(1) Trimming of the detecting surface: Splash, scale, pit and rust of the welding work surface should be removed, and the finish is generally lower than ▽4. The trimming width of the flaw detection surface on both sides of the weld is generally 2KT+50mm or more, (K: probe K value, T: workpiece thickness). Generally, the K value is 2.5 probes based on the base material of the weldment. For example, if the thickness of the base material of the workpiece to be tested is 10 mm, then 100 mm should be ground on both sides of the weld.

(2) The choice of couplant should take into account the viscosity, fluidity, adhesion, non-corrosion on the surface of the workpiece, easy to clean, and economical, the above factors are selected as the couplant.

(3) Due to the thin thickness of the base metal, the detection direction is performed on one side and both sides.

(4) Since the plate thickness is less than 20 mm, the horizontal positioning method is used to adjust the scanning speed of the instrument.

(5) Rough flaw detection and fine flaw detection are used during the flaw detection operation. In order to get an idea of the presence and absence of defects and the distribution, quantification, and positioning are fine flaws. Scanning methods such as zigzag scanning, left and right scanning, front and back scanning, corner scanning, and surround scanning are used to find various defects and judge the nature of defects.

(6) Record the detection results, and evaluate the internal defects if they are found. The internal defects of the welding pair shall be classified according to the current national standard GB/T 11345-2013 "Non-destructive testing of welds, ultrasonic testing technology, inspection grade and assessment" to judge whether the welding is qualified. If it is found that there is a defect, the rectification notice will be issued to the workshop, and the rectification will be carried out after the rectification. Common defects in general welds are: pores, slag inclusions, incomplete penetration, unfusion, and cracks. So far, there is no mature method to accurately judge the nature of the defect, but the defect is comprehensively evaluated based on the shape of the defect wave and the height of the reflected wave obtained on the screen combined with the position of the defect and the welding process.

BKNis a professionalmfl suppliers. We provide Eddy Current Testing, Magnetic Flux Leakage Testing, ndt ultrasonic testing equipment, eddy current testingand so on. Want to know more? Please contact us.



在线联系供应商

至: Nanjing BKN Automation System Co.,LTD
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

BKNET-101 Automatic Eddy Current Testing
BKNET-101 Automatic Eddy Current Testing The eddy current testing (BKNET-101) is a fully automated eddy current inspection systemthat uses large-scale imported integrated circuits combined...
Eddy Current Testing Equipment for Tube, Bar and Wire
Eddy Current Testing Equipment for Tube, Bar and Wire ECT Eddy current testing is a ndt testing equipment, which mainly uses the electromagnetic field and electromagnetic induction between metals to de...
Bolt Eddy Current Sorter BKNFX-11
Bolt Eddy Current Sorter BKNFX-11 Bolt: Mechanical parts, cylindrical threaded fasteners with nuts. A type of fastener consisting of a head and a screw (a cylinder with an external...
Rod Tube Rotary Eddy Current Flaw Detector ET 15/40/65/90
Rod Tube Rotary Eddy Current Flaw Detector ET 15/40/65/90 Rod Tube Rotary Eddy Current Flaw Detector ET 15406590 Brief Rod Tube Rotary Eddy Current Flaw Detector ET 15406590 Performance Testing Standa...
BKNET-101 Automatic Eddy Current Testing
BKNET-101 Automatic Eddy Current Testing The eddy current testing(BKNET-101) is a fully automated eddy current inspection system that uses large-scale imported integrated circuits combined...
供应产品

Same products

DM-16BF DM-18BF New cover Electric Sprayer
DM-16BF DM-18BF New cover Electric Sprayer 卖方: Zhejiang Huaqi Information Technology Co., LTD The Electric Knapsack Sprayer is a game-changer in the field of agricultural pest control. Engine...
Simple Round Breeding Cage
Simple Round Breeding Cage 卖方: Zhejiang Huaqi Information Technology Co., LTD The Simple Round Breeding Cage features a durable and lightweight construction, making it suitabl...
叙利亚-细胞储存液氮容器-液氮液位报警器
叙利亚-细胞储存液氮容器-液氮液位报警器 卖方: 河南天之道生物科技有限公司 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用...
意大利-液氮细胞储存罐-液氮罐液位报警器
意大利-液氮细胞储存罐-液氮罐液位报警器 卖方: 河南天驰仪器设备有限公司 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用...
埃及-细胞储存液氮罐-液氮液位监测仪
埃及-细胞储存液氮罐-液氮液位监测仪 卖方: Henan Tianzhidao Biological Technology Co., Ltd. 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用...