56G QSFP AOC
TS CommunicationTSQS-8556G-xxxC is a Four-Channel, Pluggable, Parallel, Fiber-Optic QSFP+ for 56 Gigabit Ethernet, compliant with the QSFP MSA, InfiniBand FDR/QDR/DDR/SDR, 2G/4G/8G/10G/16G Fiber Channel, PCIe and SAS. This transceiver is a high-performance module for short-range multi-lane data communication and interconnect applications. It integrates four full-duplex lanes in each direction with 56 Gbps bandwidth. The length is up to 100 meters using OM3 MMF.
Features of 56G QSFP+ AOC
Four-channel full-duplex active optical cable with QSFP+ plugs
Electrical interface compliant to SFF-8436
Support 56GE data rate
Hot Pluggable
Built-in digital diagnostic functions
Operating case temperature 0℃ to 70℃
RoHS compliant
Applications of 56G QSFP+ AOC
Data Centers
Infiniband transmission, High-performance computing (HPC) application
Specifications of 56G QSFP+ AOC
Absolute Maximum Ratings
|
Parameter |
Symbol |
Min |
Max |
Unit |
|
Storage Temperature |
TS |
-20 |
85 |
℃ |
|
Relative Humidity |
RH |
0 |
85 |
% |
|
Case Operating Temperature |
TCase |
0 |
70 |
℃ |
|
Supply Voltage |
VCC |
-0.5 |
V |
Recommended Operating Conditions
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
|
Case Operating Temperature |
TCase |
0 |
70 |
℃ |
|
|
Supply Voltage |
VCC |
V |
|||
|
Differential Data Input Voltage Per Lane |
Vdin |
200 |
1200 |
mVp-p |
|
|
Data Rate Per Lane |
DR |
Gbit/s |
Electrical Characteristics
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
|
Bit Error Ratio |
BER |
10-12 |
|||
|
Differential Data Output Voltage Per Lane |
Vdout |
320 |
450 |
mVp-p |
|
|
Differential Termination Resistance |
Zout |
80 |
100 |
120 |
Ohm |
|
Module Total Power |
P |
W |
|||
|
Transmit Turn-On Time |
2000 |
ms |
Pin Definitionsof56G QSFP+ AOC
|
Pin |
Symbol |
Name/Description |
|
1 |
GND |
Ground |
|
2 |
Tx2n |
Transmitter Inverted Data Input |
|
3 |
Tx2p |
Transmitter Non-Inverted Data Input |
|
4 |
GND |
Ground |
|
5 |
Tx4n |
Transmitter Inverted Data Input |
|
6 |
Tx4p |
Transmitter Non-Inverted Data Input |
|
7 |
GND |
Ground |
|
8 |
ModSelL |
Module Select |
|
9 |
ResetL |
Module Reset |
|
10 |
Vcc Rx |
+3.3 V Power supply receiver |
|
11 |
SCL |
2-wire serial interface clock |
|
12 |
SDA |
2-wire serial interface data |
|
13 |
GND |
Ground |
|
14 |
Rx3p |
Receiver Non-Inverted Data Output |
|
15 |
Rx3n |
Receiver Inverted Data Output |
|
16 |
GND |
Ground |
|
17 |
Rx1p |
Receiver Non-Inverted Data Output |
|
18 |
Rx1n |
Receiver Inverted Data Output |
|
19 |
GND |
Ground |
|
20 |
GND |
Ground |
|
21 |
Rx2n |
Receiver Inverted Data Output |
|
22 |
Rx2p |
Receiver Non-Inverted Data Output |
|
23 |
GND |
Ground |
|
24 |
Rx4n |
Receiver Inverted Data Output |
|
25 |
Rx4p |
Receiver Non-Inverted Data Output |
|
26 |
GND |
Ground |
|
27 |
ModPrsL |
Module Present |
|
28 |
IntL |
Interrupt |
|
29 |
Vcc Tx |
+3.3 V Power supply transmitter |
|
30 |
Vcc1 |
+3.3 V Power Supply |
|
31 |
LPMode |
Low Power Mode |
|
32 |
GND |
Ground |
|
33 |
Tx3p |
Transmitter Non-Inverted Data Input |
|
34 |
Tx3n |
Transmitter Inverted Data Input |
|
35 |
GND |
Ground |
|
36 |
Tx1p |
Transmitter Non-Inverted Data Input |
|
37 |
Tx1n |
Transmitter Inverted Data Input |
|
38 |
GND |
Ground |
在线联系供应商
Other supplier products
| FBG OPTICAL BRAGG GRATTING SENSORS | Being a fiber optic sensor, a FBG sensor has all the advantages usually attributed to these devices, such as low loss relative to the fiber length,... | |
| PLC TYPE WDM | Instead of taking a thin film filter to mux or demux wavelengths, PLC type achieves the same goal by using chip PLC, which uniformly divides and gu... | |
| 40g aoc | T&SCommunication TSQS-8540G-xxxC is a four-channel, pluggable, and parallel fiber-optic QSFP+SR4 for 40-gigabit ethernet and it is compliant wi... | |
| QSFP28 100G SR4 100M | QSFP28 100G SR4 100M The QSFP28 100G-SR4-100m module is a highly integrated 4x25G transceiver focused on reach, bandwidth, density and cost for hig... | |
| Reason Analysis of Using AOC Active Optical Cable in Data Center Wiring | 40G/100G AOC active optical cable has been globally introduced throughout the aoc data centerfield. Compared to 40G DAC copper cable, 40G AOC activ... |