Dry magnetic-shielding shunt reactor high voltage and medium voltage

Connected in parallel at one winding side of substation transformers at various levels. When the charging power of a voltage level transmission line reaches the regulatory limit, a shunt reactor should be installed for the capacitive reactive power of long-distance light-load transmission lines. Volt-ampere compensation.
Use environment
1) Use environment: indoors, outdoors
2) Ambient temperature: -40 °C ~ +45 °C (or according to user requirements)
3) Altitude: ≤1000m (or according to user requirements)
4) Installation and operation location: It should be free of severe vibration or bumps, and can withstand earthquakes with seismic intensity of 8 degrees without damage.
5) Installation location: No harmful gas, steam, conductive or explosive dust
6) Pay attention to ventilation during indoor use
7) Maximum wind speed: no more than 35m/s
8) Relative humidity: The monthly average is no more than 90%, and the daily average is no more than 95%.
Note: Please contact with our company for special requirements. We are willing to wholeheartedly meet your requirements.


在线联系供应商

至: Shandong Taikai Power Electronic Co., Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Dry air-core current-limiting reactor high voltage and medium voltage
Dry air-core current-limiting reactor high voltage and medium voltage Current-limiting reactors, limit the short-circuit current, and reduce the short-circuit current to the allowable value of the device. Use environm...
widely used suppress harmonic high-voltage filter and compensation FC filter capacitor
widely used suppress harmonic high-voltage filter and compensation FC filter capacitor The load of iron and steel, petrochemical, metallurgy, coal, printing and dyeing industries will generate a large number of harmonics during the wo...
achieve automatic group switching Shunt Capacitor bank automatic compensation-TBBZ
achieve automatic group switching Shunt Capacitor bank automatic compensation-TBBZ Mainly by the TRZ controller, vacuum contactors, high-voltage shunt capacitors, series reactors, fuses (or internal fuses), zinc oxide arresters, d...
reduce harmonics  low active loss fast response speed Magnetic-valve Controllable Reactor MCR-type SVC
reduce harmonics low active loss fast response speed Magnetic-valve Controllable Reactor MCR-type SVC MCR (Magnetic-valve Controllable Reactor) Type SVC MCR type SVC uses self-coupling DC excitation and limiting magnetic saturation work mode, which ...
high-voltage automatic Thyristor Switched Capacitor TSC-type SVC factory price
high-voltage automatic Thyristor Switched Capacitor TSC-type SVC factory price TSC (Thyristor Switched Capacitor) Type SVC The high-voltage TSC dynamic reactive power compensation device consists of a control system, a trigger...
供应产品

Same products

chemical equipments
chemical equipments 卖方: rachanashakti fabtech pvt ltd chemical process equipment, storage silo & platforms, Pharmaceutical equipment, Storage Tanks, Pr...
chemical equipments
chemical equipments 卖方: rachanashakti fabtech pvt ltd chemical process equipment, storage silo & platforms, Pharmaceutical equipment, Storage Tanks, Pr...
WAVE FILTER
WAVE FILTER 卖方: Fujian Hongyan Electrical Company Limited The sine wave filter is driven by PWM inverter, and its switching frequency range is between 2-8k...
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR)
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR) 卖方: Fujian Hongyan Electrical Company Limited It is installed at the output end of the inverter to limit the capacitive charging current of the...
Dry magnetic-shielding shunt reactor high voltage and medium voltage
Dry magnetic-shielding shunt reactor high voltage and medium voltage 卖方: Shandong Taikai Power Electronic Co., Ltd. Connected in parallel at one winding side of substation transformers at various levels. When the ...