How to calculate the calorific value of transformer

How to calculate the calorific value of transformer

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.


在线联系供应商

至: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Transformer energy-saving more and more popularize
Transformer energy-saving more and more popularize Dry Type Transformer Manufacturershares that the transformer also has the very big development and the change in carries on the development exper...
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer...
How to see the oil position of oil-immersed transformer?
How to see the oil position of oil-immersed transformer? oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambi...
What are the steps of transformer maintenance
What are the steps of transformer maintenance What are the steps of transformer maintenance Transformer is an important electrical equipment that must be used in our production and life. For tr...
Fixed mounted Switchgear
Fixed mounted Switchgear Low Voltage Switchgear High and Low Voltage Switchgears GGD series low voltage switchgearis used for power lighting Product Description GGD series ...
供应产品

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER 卖方: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...