How to calculate the calorific value of transformer

How to calculate the calorific value of transformer

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.


Send product request

To: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Amorphous alloy power transformer China
Amorphous alloy power transformer China is a new type of energy saving transformer made of a new magnetic conducting material (amorphous alloy). It is more than 70% lower than the no-loa...
Transformer Energy Saving is More and More Popularized
Transformer Energy Saving is More and More Popularized Transformers such asThree Phase Transformeralso have great developments and changes in the development experience, and the process of transformer ...
Dry type Power Transformers
Dry type Power Transformers Product Description SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) d...
What is the short circuit impedance of transformer
What is the short circuit impedance of transformer What is the short circuit impedance of transformer Do you know what the short circuit impedance of transformer is? Transformer such as the, it is a...
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer...
All supplier products

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER Seller: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...