[FA-] MPY-S, MPYC-S, MPYCY-S
250V [FA-] MPY-S,Website:, MPYC-S, MPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper, class 2 according to IEC 60228InsulationP85°C EPR as per JIS C 3401Individual shield-STinned copper wire braidCablingInsulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be usedBeddingYPVC as per JIS C 3401ArmorCGalvanized steel wire braidSheathYPVC as per JIS C 3401Core identificationBlack No. on white insulationOuter sheath colorBlackCable Parameter250V (FA-) MPY-SNo. of coresConductorThick. of insulationDia. of shield wireThick. of bedding(FA-) MPY-SSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmmmkg/km217/0.431.290.70.121.19.90.4150417/0.431.290.70.121.211.60.5230717/0.431.290.70.121.313.90.63501217/0.431.290.70.121.418.20.85701917/0.431.290.70.121.521.50.98402717/0.431.290.70.121.7261.112003717/0.431.290.70.121.829.21.216004417/0.431.290.70.12233.21.42000250V (FA-) MPYC-SNo. of coresConductorThick. of insulationDia. of shield wireThick. of beddingDia. of steel wire(FA-) MPYC-SSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmmmmmkg/km217/0.431.290.70.121.10.311.20.4210417/0.431.290.70.121.20.312.90.5300717/0.431.290.70.121.30.315.20.64351217/0.431.290.70.121.40.319.50.86851917/0.431.290.70.121.50.322.80.99802717/0.431.290.70.121.70.327.31.113603717/0.431.290.70.121.80.330.51.217604417/0.431.290.70.1220.4351.42240250V (FA-) MPYCY-SNo. of coresConductorThick. of insulationDia. of shield wireThick. of beddingDia. of steel wireThick. of covering(FA-) MPYCY-SSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmmmmmmmkg/km217/0.431.290.70.121.10.30.913.20.5260417/0.431.290.70.121.20.30.914.90.6360717/0.431.290.70.121.30.3117.40.75151217/0.431.290.70.121.40.31.121.90.97951917/0.431.290.70.121.50.31.225.4111202717/0.431.290.70.121.70.31.330.11.215403717/0.431.290.70.121.80.31.433.51.319704417/0.431.290.70.1220.41.538.41.52500
Other supplier products
|
|
300/500V PVC Insulated,Website:, PVC Sheathed Power Cables (2-5 Cores)05VV-K (CU/PVC/PVC 300/500V Class 5)BS Code: 3182Y/3183Y/3184Y/3185YHAR Code:... |
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multipair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic desig... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 8776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Armoured Instrumentation & Control CablesApplication:The... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9830ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |