0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754- 2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.37.60.31.19.811.72201×61.01.06.88.10.31.110.412.22501×101.01.07.79.10.31.211.513.43101×161.01.18.910.30.31.212.714.64001×251.21.211.112.80.31.315.017.35701×351.21.212.013.70.31.416.118.46601×501.41.313.715.50.31.417.920.28701×701.41.315.517.40.31.519.822.611101×951.61.417.719.80.31.622.225.214601×1201.61.519.622.00.31.724.327.317701×1501.81.621.624.20.31.826.529.721101×1852.01.724.026.60.451.929.833.527201×2402.21.827.129.90.452.033.136.934101×3002.41.930.033.20.452.136.240.14180Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×10.81.07.58.80.31.211.313.12302×1.50.81.18.29.60.31.212.013.92702×2.50.81.19.010.40.31.212.814.73202×41.01.211.012.70.31.315.017.24302×61.01.212.113.80.31.416.318.55302×101.01.314.115.90.31.418.220.66602×161.01.416.318.30.31.520.623.58402×251.21.520.422.90.31.725.228.213102×351.21.622.424.90.31.827.330.416002×501.41.725.728.40.452.031.735.522402×701.41.929.632.70.452.135.839.729002×951.62.134.137.40.452.340.745.238602×1201.62.237.741.10.452.544.649.346503×10.81.18.29.50.31.211.913.82503×1.50.81.18.710.10.31.212.514.43053×2.50.81.19.611.00.31.313.515.53603×41.01.211.713.40.31.315.717.94953×61.01.212.914.70.31.417.019.46003×101.01.315.017.00.31.519.422.28103×161.01.417.419.40.31.621.924.810703×251.21.622.024.60.31.826.930.116203×351.21.724.126.70.451.929.933.621303×501.41.827.730.50.452.033.737.527503×701.42.031.835.10.452.238.242.236603×951.62.236.740.10.452.443.548.147403×1201.62.340.544.40.452.647.752.559503×1501.82.544.949.00.452.852.557.871203×1852.02.750.154.60.453.058.064.088203×2402.22.956.761.50.453.265.071.3112803×3002.43.263.168.60.453.572.079.0136404×10.81.18.910.30.31.212.614.62804×1.50.81.19.510.90.31.313.515.43504×2.50.81.110.512.10.31.314.416.44104×41.01.212.914.60.31.417.019.35704×61.01.314.416.20.31.518.721.17304×101.01.416.718.70.31.621.324.19904×161.01.519.421.80.31.724.127.113304×251.21.724.527.10.451.930.334.021504×351.21.826.829.50.452.032.836.626004×501.41.930.834.00.452.237.241.234104×701.42.135.438.80.452.442.246.745304×951.62.340.844.70.452.647.952.759404×1201.62.545.249.30.452.852.858.273904×1501.82.750.154.70.453.058.164.187004×1852.02.955.860.70.453.264.170.4107804×2402.23.263.468.90.453.572.379.3138405×1.50.81.110.412.00.31.314.316.33957×1.50.81.211.513.20.31.315.417.746012×1.50.81.315.217.20.31.519.622.468019×1.50.81.418.020.10.31.622.525.593027×1.50.81.621.924.50.31.826.830.0127037×1.50.81.724.727.30.31.930.534.217405×2.50.81.211.713.30.31.315.617.84807×2.50.81.212.714.40.31.416.819.157012×2.50.81.417.119.10.31.621.624.588019×2.50.81.520.222.70.31.724.928.01220
Other supplier products
|
|
|
Type 2S 1.1/1.1KV & 3.3/3.3KV Individually ScreenedApplicationsThese individually copper screened cables are used for wiring of machines or between... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8335ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant... |
|
|
|
3.6/6KV,Website:, 6/10KV, 8.7/15KV, (FA-)SPYC, SPYCB, TPYC (FA-)SPYCY, SPYCBY, TPYCYStandards:JISC 3410-1999
IEC 60092-350
IEC 60092-35... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
供应产品