0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754- 2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.37.60.31.19.811.72201×61.01.06.88.10.31.110.412.22501×101.01.07.79.10.31.211.513.43101×161.01.18.910.30.31.212.714.64001×251.21.211.112.80.31.315.017.35701×351.21.212.013.70.31.416.118.46601×501.41.313.715.50.31.417.920.28701×701.41.315.517.40.31.519.822.611101×951.61.417.719.80.31.622.225.214601×1201.61.519.622.00.31.724.327.317701×1501.81.621.624.20.31.826.529.721101×1852.01.724.026.60.451.929.833.527201×2402.21.827.129.90.452.033.136.934101×3002.41.930.033.20.452.136.240.14180Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×10.81.07.58.80.31.211.313.12302×1.50.81.18.29.60.31.212.013.92702×2.50.81.19.010.40.31.212.814.73202×41.01.211.012.70.31.315.017.24302×61.01.212.113.80.31.416.318.55302×101.01.314.115.90.31.418.220.66602×161.01.416.318.30.31.520.623.58402×251.21.520.422.90.31.725.228.213102×351.21.622.424.90.31.827.330.416002×501.41.725.728.40.452.031.735.522402×701.41.929.632.70.452.135.839.729002×951.62.134.137.40.452.340.745.238602×1201.62.237.741.10.452.544.649.346503×10.81.18.29.50.31.211.913.82503×1.50.81.18.710.10.31.212.514.43053×2.50.81.19.611.00.31.313.515.53603×41.01.211.713.40.31.315.717.94953×61.01.212.914.70.31.417.019.46003×101.01.315.017.00.31.519.422.28103×161.01.417.419.40.31.621.924.810703×251.21.622.024.60.31.826.930.116203×351.21.724.126.70.451.929.933.621303×501.41.827.730.50.452.033.737.527503×701.42.031.835.10.452.238.242.236603×951.62.236.740.10.452.443.548.147403×1201.62.340.544.40.452.647.752.559503×1501.82.544.949.00.452.852.557.871203×1852.02.750.154.60.453.058.064.088203×2402.22.956.761.50.453.265.071.3112803×3002.43.263.168.60.453.572.079.0136404×10.81.18.910.30.31.212.614.62804×1.50.81.19.510.90.31.313.515.43504×2.50.81.110.512.10.31.314.416.44104×41.01.212.914.60.31.417.019.35704×61.01.314.416.20.31.518.721.17304×101.01.416.718.70.31.621.324.19904×161.01.519.421.80.31.724.127.113304×251.21.724.527.10.451.930.334.021504×351.21.826.829.50.452.032.836.626004×501.41.930.834.00.452.237.241.234104×701.42.135.438.80.452.442.246.745304×951.62.340.844.70.452.647.952.759404×1201.62.545.249.30.452.852.858.273904×1501.82.750.154.70.453.058.164.187004×1852.02.955.860.70.453.264.170.4107804×2402.23.263.468.90.453.572.379.3138405×1.50.81.110.412.00.31.314.316.33957×1.50.81.211.513.20.31.315.417.746012×1.50.81.315.217.20.31.519.622.468019×1.50.81.418.020.10.31.622.525.593027×1.50.81.621.924.50.31.826.830.0127037×1.50.81.724.727.30.31.930.534.217405×2.50.81.211.713.30.31.315.617.84807×2.50.81.212.714.40.31.416.819.157012×2.50.81.417.119.10.31.621.624.588019×2.50.81.520.222.70.31.724.928.01220
Other supplier products
|
|
|
Mud Resistant Cat 5e S/FTP 0.22mm2 IEC60092ApplicationThese Cat5e S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website... |
|
|
|
150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple)Ap... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric in... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic des... |
|
|
|
UL Industrial Cables XHH / XHHW-2Application and DescriptionThe XHH conductor is suitable for most current wiring solutions for residential,Website... |
供应产品
Same products