Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381

Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for use on longwall shearers,Website:, where three shielded power conductors, three unshielded control conductors, and a grounding conductor are required.StandardsICEA S-75-381/NEMA WC 58ASTM B 172ASTM B 33CAN/CSA C22.2 No. 96ConstructionConductorsStranded annealed tinned copper conductor.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldTinned copper/textile braid.Control Group (3 Conductor)Tinned copper conductor, EPR insulation and thermosetting jacket. Colour of insulation: Black, white and red.Grounding ConductorTinned copper conductor, located in the center of the cable.JacketReinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 6×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeControl Conductor SizeNominal Insulation ThicknessNominalJacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×2259480.112.80.2055.22.0351.×1259480.112.80.2205.62.1253.×1/0266380.112.80.2205.62.2757.×2/0329280.112.80.2205.62.4562.×3/0418180.112.80.2356.02.5865.×4/05321/060.112.80.2506.42.7669.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
German Standard Industrial Cables H05G-U/H07G-U/RApplication and DescriptionThese cables are recommended for the internal wiring of switchboards an... |
|
|
|
P2 or P2/P9 RFOU/TFOU 3.6/6KV NEK606 MV cableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, us... |
|
|
|
Fire resistant RG59 B/U Coaxial cables RG59 B/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
|
|
|
Type 441 (class 1) 3.3 to 22KV to AS/NZS 2802ApplicationsType 441 Class 1 series cable has lower insulation and sheath radials than Class 2 cables,... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
供应产品
Same products