Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 25kV To ICEA S-75-381
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 8kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominalJacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.1152.90.112.81.4135.×47880.1152.90.112.81.5238.×27680.1152.90.112.81.5840.×119580.1152.90.112.81.6642.×1/019480.1152.90.112.81.7444.×2/019380.1152.90.143.61.9048.×3/019280.1152.90.143.62.0050.×4/019180.1152.90.143.62.1253.×250371/080.1152.90.143.62.2256.×350372/080.1152.90.143.62.4361.×500374/080.1152.90.143.62.7068.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8125ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
Type SHD-GC Three-Conductor Portable Power Cable,Website:, TPU Jacket 15kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applic... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8333ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant... |
|
|
Type 210 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used for hand-held boring machines and drills.StandardsAS/NZS 1802:2003AS/NZS ... |