Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 25kV To ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 8kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominalJacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.1152.90.112.81.4135.×47880.1152.90.112.81.5238.×27680.1152.90.112.81.5840.×119580.1152.90.112.81.6642.×1/019480.1152.90.112.81.7444.×2/019380.1152.90.143.61.9048.×3/019280.1152.90.143.62.0050.×4/019180.1152.90.143.62.1253.×250371/080.1152.90.143.62.2256.×350372/080.1152.90.143.62.4361.×500374/080.1152.90.143.62.7068.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
|
UL Industrial Cables AL-XHHW-2 Power Cable,Website:, CT RatedApplication and DescriptionType XHHW-2 conductors are primarily used in conduit or rec... |
|
|
|
Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth ... |
|
|
|
50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour... |
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 28538ApplicationsThese multicore unscreened armoured cables are Type MC Metal Clad cables.Co... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9735ApplicationsThese cables have individually screened pairs laid up. Each individually s... |