Type 240 1.1 To 11KV To AS/NZS 1802
Type 240 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are mainly used as feeder cables for power supply to machinery or longwall supply.Cable contains 3 large pilots and large core screens provide for low resistance earthing.StandardsAS/NZS 1802:2003AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.Composite Screen (earth conductor)Tinned annealed copper braiding interwove with polyester yarn.3×Interstitial PilotEPR covered flexible stranded tinned copper conductor.Cradle SeparatorSemiconductive PCP.SheathHeavy duty PCP sheath.Heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrandSizeInsulation ThicknessCore screenPilot ConductorThickness of SheathNominal Overall DiameterNominal WeightStrandSizeArea of ScreenStrand SizeThickness of Coveringmm2No/mmmmNo/mmmm2No/mmmmmmmmkg/100mType 240.1684/0.301.57/0.257.218/0.301.03.830.01311077/0.401.57/0.258.627/0.301.03.832.615916126/0.401.67/0.259.642/0.301.04.035.820225209/0.401.67/0.2511.366/0.301.24.339.726535285/0.401.67/0.2512.490/0.301.24.643.132650380/0.401.77/0.2514.1120/0.301.25.047.740470203/0.671.87/0.2516.539/0.671.25.453.953395259/0.672.07/0.2518.239/0.671.26.058.6635120336/0.672.17/0.2520.342/0.671.46.464.4775150427/0.672.37/0.2522.354/0.671.46.970.2940185518/0.672.57/0.3030.263/0.671.47.477./0.672.87/0.3033.677/0.671.68.286./0.673.07/0.4050.198/0.671.68.895.11810Type 240.316126/0.403.07/0.2513.142/0.301.45.346.230625209/0.403.07/0.2514.866/0.301.45.650.137935285/0.403.07/0.2515.890/0.301.45.953.544450380/0.403.07/0.2517.2120/0.301.46.357.652570203/0.673.07/0.2518.639/0.671.46.662.565695259/0.673.07/0.2520.339/0.671.47.166.2750120336/0.673.07/0.3027.242/0.671.67.472.0910150427/0.673.07/0.4039.654/0.671.67.878./0.673.07/0.4042.263/0.671.88.283./0.673.07/0.4046.677/0.671.88.890./0.673.07/0.5063.298/0.671.89.498.41920Type 240.616126/0.405.07/0.2517.242/0.301.46.457.344025209/0.405.07/0.2518.666/0.301.46.761.252135285/0.405.07/0.2518.690/0.301.67.064.659350380/0.405.07/0.2521.3120/0.301.67.368.568570203/0.675.07/0.2523.439/0.671.67.773.783095259/0.675.07/0.3029.239/0.671.68.177.8954120336/0.675.07/0.3031.742/0.671.88.583./0.675.07/0.4045.754/0.671.88.989./0.675.07/0.4048.463/0.671.89.394./0.675.07/0.4052.877/0.671.89.9101./0.675.07/0.5071.598/0.671.810.4109.32190Type 240.1125209/0.407.67/0.2523.766/0.302.08.175.675235285/0.407.67/0.3030.290/0.302.08.479.786050380/0.407.67/0.3031.7120/0.302.08.783.696170203/0.677.67/0.3034.139/0.672.09.188.8112595259/0.677.67/0.4047.539/0.672.09.693./0.677.67/0.4051.042/0.672.29.998./0.677.67/0.4053.754/0.672.210.3103./0.677.67/0.4057.263/0.672.210.7108.81880
Website:
Other supplier products
|
|
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1)Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath)ApplicationThes... |
|
|
NTMCGCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for conne... |
|
|
0.6/1KV [FA-] SPYCS,Website:, SPYCBS, DPYCS, TPYCS, FPYCS [FA-] SPYCYS, SPYCBYS, DPYCYS, TPYCYS, FPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332... |
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9844ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
供应产品
Same products