Harmonized Code Industrial Cables H05V3V3H6-F H05V3V3D3H6-F

Harmonized Code Industrial Cables H05V3V3H6-F/ H05V3V3D3H6-FApplication and DescriptionThis kind of flat cables are used in crews of elevators for people and have burdens,Website:, and conducting very swift and hard parts of machines.H05V3V3H6-F type cables having no strechter carrier elements are adviced to use in elevator instalations max. swift not pass 4.0 m/s.These cables freely hanging height is max. 45m and movement limit is max 80m. For tde H05V3V3D3H6-F, at tde swifts between 4.0/s to 6.3m/s, it’s adviced to use tde cables having strechter carrier elements. H05V3V3D3H6-F type cables freely hanging height is max. 80m movement limit is max. 150m.Standard and ApprovalEN 50214HD 359 S3IEC 60332-1CSA C22.2 N° 49DIN VDE 0281 part 404UL 62Cable ConstructionBare copper strand conductoracc. to DIN VDE 0295 class 5/6 resp. IEC 60228 class 5/6PVC T15 core insulationColor coded to VDE 0293-308, >6 wires black witd white numerals witd green/yellow wireBlack PVC TM 4 sheatdTechnical CharacteristicsWORKING VOLTAGE: 300/500VTEST VOLTAGE: 2000VFLEXING TEMPERATURE: -35 ºC to +70 ºCFLAME RETARDANT: IEC 60332 -1INSULATION RESISTANCE: 350 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREANOMINAL OVERALL DIMENSIONNOMINAL COPPER WEIGHTNOMINAL WEIGHT# X MM²MMKG/KMKG/KMH05V3V3H6-F18(24/32)12 x 0.7533.7 x 4./32)16 x 0.7544.5 x 4./32)18 x 0.7549.2 x 4./32)20 x 0.7555.0 x 4./32)24 x 0.7565.7 x 4./32)12 x 135.0 x 4./32)16 x 151.0 x 4./32)20 x 157.0 x 4./32)24 x 168.0 x 4.4210565H05V3V3D3H6-F18(24/32)20 x 0.7561.8 x 4./32)24 x 0.7572.4 x 4./32)12 x 141.8 x 4./32)14 x 147.8 x 4./32)18 x 157.8 x 4./32)22 x 169.8 x 4./32)24 x 174.8 x 4.3210617
Other supplier products
|
|
|
Harmonized Code Industrial Cables H05V-R/H07V-RApplication and DescriptionThese cables are preferably for installation indoors,Website:, in cable d... |
|
|
|
Multipair Individually and Overall Screened Cables-Belden Equivalent 8178ApplicationsThese cables have individually screened pairs laid up in a foi... |
|
|
|
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS... |
|
|
|
P18 RU 0.6/1kV NEK606 CableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for control, po... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8302ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |