ACREL DJSF SERIES DC ENERGY METER

Acrel DJSF Series modbus dc power meterwith double channels DC input is mainly designed for telecom base station, DC charging pile, solar photovoltaic and other applications. This series of meters can measure voltage, current, power and positive and negative energy in the DC system.

DJSF Series DC Energy Meter For Sale

● RS485 communication, Modbus-RTU protocol ● kWh, kVarh, Power, Current, Voltage measure ● suitable for Charging Pile; Solar PV, battery system ● two channel dc circuits, event recording, max demand

DJSF1352-RN Din Rail kWh Meter DC

DJSF Series DC Energy Meter Datasheet

Technical parameters

Indicators

Input

Nominal value

Voltage input range

Current input

DC 0-1000V

Shunt:0-75mV;

See the physical wiring diagram

Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on.

Overload

Power consumption

Voltage: ≤0.2VA, current ≤0.1VA

Accuracy class

Class 1

Function

Display

8-bit segment LCD screen (LCD)

Communication Interface

RS485, infrared

Communication protocol

Modbus-RTU, DL/T 645-2007

Switch

Switch output

2 Relay outputs, 2A/30VDC or 2A/250VA

Switch input

2 dry contact inputs

Pulse output

A second pulse output, a energy pulse output

See the SYS->PLUS display in the meter menu setting

For example: The meter displays 100, which is 100imp/kWH

Power Supply

Voltage range

AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)

Power consumption

≤ 3W

Power frequency withstand voltage

Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min

Insulation resistance

≥ 40M Ω

Average barrier-free working hours

≥50000h

Environment

Temperature

Normal operating temperature: -25 °C ~ +65 °C;

Limit working temperature: -40 °C ~ +70 °C;

Storage temperature: -40℃~+80℃

Humidity

≤93%RH, no condensation, no corrosive gas

Altitude

≤2500m

How Does A DJSF Series DC Energy Meter Work?

DJSF1352-RN has two channels dc circuits input. The input voltage shall not be higher than 120% of the rated input voltage of the product. 1A fuse shall be installed at the voltage input end. The current input should be external shunt or Hall current sensor. The instrument provides RS485 communication interface and supports Modbus-RTU protocol. Theoretically, up to 128 instruments can be connected on a line at the same time. Each instrument can set its Addr and baud, and also can be selected by setting.

DJSF Series DC Energy Meter FAQs

what is a DJSF DC energy meter?

DJSF dc energy meter with rs485is designed for DC screen, solar power supply, telecom base station, subway and other applications.

how does a DJSF DC energy meter work?

The DC voltage and the DC current are measured separately with two DMM, and the results are multiplied to get the DC power.

How does a DJSF energy meter Installation?

use 35mm guide rail which is convenient and quick to install.

Which signal input does DJSF dc energy meter support?

voltage supports 1000V input, current supports shunt (0-75mV), Hall sensor (0-20mA, 4-20mA, 0-5V) access.

Now the price of power meter for solar panelsis low, if you are interested, please contact us.


在线联系供应商

至: Jiangsu Acrel Electrical Manufacturing Co., LTD.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

ACREL ARTU-K32 REMOTE TERMINAL UNIT
ACREL ARTU-K32 REMOTE TERMINAL UNIT ARTU-K32 Series Remote Terminal Unit:RS485 (MODBUS -RTU);channel state indicator and communication state indicator; 24VDC, range DC18~36V; 220VA...
NEW ENERGY DEVICE
NEW ENERGY DEVICE Acrel new energy insulation monitoring device abbis mainly used in solar PV system and EV charger. Nowadays, the world advocates a green, environme...
ACREL ADW SERIES IOT POWER METER
ACREL ADW SERIES IOT POWER METER Acrel ADW series energy meter using iotcompared with smart energy meter has the biggest advantage is that it can be controlled by wireless communic...
ISOLATED POWER SYSTEMS
ISOLATED POWER SYSTEMS Acrel Isolated power monitoring and control systemare mainly used in the medical and industrial sectors. The medical IT system is mainly designed f...
ENERGY MANAGEMENT DEVICES
ENERGY MANAGEMENT DEVICES Acrel Power Meters and Energy Management system is in accordance with the needs of users, in accordance with the standard specifications of the dis...
供应产品

Same products

 INTERFLON Food 2 Grease for the lubrication of foodstuff machines 400ml
INTERFLON Food 2 Grease for the lubrication of foodstuff machines 400ml 卖方: Dongguan Fuxiaojing New Materials Technology Co., Ltd Intended for the general lubrication of machine parts with slow to medium-fast movements and ligh...
YAMADA MMG-80 MP 85ml for Bearing Sliding Parts
YAMADA MMG-80 MP 85ml for Bearing Sliding Parts 卖方: Dongguan Fuxiaojing New Materials Technology Co., Ltd It is a heat-resistant, extreme pressure, water resistant, durable, lithium soap universal grease
Mobil Grease Unirex N3 for High-Temperature Service in Rolling-Element Bearings
Mobil Grease Unirex N3 for High-Temperature Service in Rolling-Element Bearings 卖方: Dongguan Fuxiaojing New Materials Technology Co., Ltd Mobilgrease UNIREX™ N 3 is a high-performance, lithium complex grease (NLGI 3) with excelle...
双柱光伏安装
双柱光伏安装 卖方: 台州东升新能源科技有限公司 双柱光伏支架采用对称双柱结构,横向连接件增强了整体刚度。承重和抗风性能明显优于单柱。主体为镀锌钢或铝合金,适用于大跨度构件布置和高角度设计。基础可以配备预埋桩或混凝土桥墩。适用于高风压或大雪荷载...
Coltri oil ST 755 Fully Synthetic compressor oil 1L Food Grade lubrication
Coltri oil ST 755 Fully Synthetic compressor oil 1L Food Grade lubrication 卖方: Dongguan Fuxiaojing New Materials Technology Co., Ltd The lubricant formula Coltri Oil ST 755 is an optimized blend of synthetic hydrocarbons and pure ...