ACREL DJSF SERIES DC ENERGY METER
Acrel DJSF Series modbus dc power meterwith double channels DC input is mainly designed for telecom base station, DC charging pile, solar photovoltaic and other applications. This series of meters can measure voltage, current, power and positive and negative energy in the DC system.
DJSF Series DC Energy Meter For Sale
● RS485 communication, Modbus-RTU protocol ● kWh, kVarh, Power, Current, Voltage measure ● suitable for Charging Pile; Solar PV, battery system ● two channel dc circuits, event recording, max demand
DJSF1352-RN Din Rail kWh Meter DC
DJSF Series DC Energy Meter Datasheet
|
Technical parameters |
Indicators |
||
|
Input |
Nominal value |
Voltage input range |
Current input |
|
DC 0-1000V |
Shunt:0-75mV; |
||
|
See the physical wiring diagram |
Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. |
||
|
Overload |
|||
|
Power consumption |
Voltage: ≤0.2VA, current ≤0.1VA |
||
|
Accuracy class |
Class 1 |
||
|
Function |
Display |
8-bit segment LCD screen (LCD) |
|
|
Communication Interface |
RS485, infrared |
||
|
Communication protocol |
Modbus-RTU, DL/T 645-2007 |
||
|
Switch |
Switch output |
2 Relay outputs, 2A/30VDC or 2A/250VA |
|
|
Switch input |
2 dry contact inputs |
||
|
Pulse output |
A second pulse output, a energy pulse output |
||
|
See the SYS->PLUS display in the meter menu setting |
|||
|
For example: The meter displays 100, which is 100imp/kWH |
|||
|
Power Supply |
Voltage range |
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) |
|
|
Power consumption |
≤ 3W |
||
|
Power frequency withstand voltage |
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min |
||
|
Insulation resistance |
≥ 40M Ω |
||
|
Average barrier-free working hours |
≥50000h |
||
|
Environment |
Temperature |
Normal operating temperature: -25 °C ~ +65 °C; |
|
|
Limit working temperature: -40 °C ~ +70 °C; |
|||
|
Storage temperature: -40℃~+80℃ |
|||
|
Humidity |
≤93%RH, no condensation, no corrosive gas |
||
|
Altitude |
≤2500m |
||
How Does A DJSF Series DC Energy Meter Work?
DJSF1352-RN has two channels dc circuits input. The input voltage shall not be higher than 120% of the rated input voltage of the product. 1A fuse shall be installed at the voltage input end. The current input should be external shunt or Hall current sensor. The instrument provides RS485 communication interface and supports Modbus-RTU protocol. Theoretically, up to 128 instruments can be connected on a line at the same time. Each instrument can set its Addr and baud, and also can be selected by setting.
DJSF Series DC Energy Meter FAQs
what is a DJSF DC energy meter?
DJSF dc energy meter with rs485is designed for DC screen, solar power supply, telecom base station, subway and other applications.
how does a DJSF DC energy meter work?
The DC voltage and the DC current are measured separately with two DMM, and the results are multiplied to get the DC power.
How does a DJSF energy meter Installation?
use 35mm guide rail which is convenient and quick to install.
Which signal input does DJSF dc energy meter support?
voltage supports 1000V input, current supports shunt (0-75mV), Hall sensor (0-20mA, 4-20mA, 0-5V) access.
Now the price of power meter for solar panelsis low, if you are interested, please contact us.
Send product request
Other supplier products
| ACREL ATC600 WIRELESS TEMPERATURE TRANSMIT | ATC600wireless transceiver is used with ARTM wireless temperature measurement system. It can be used in 3~35kV indoor switch cabinets, including ce... | |
| ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC panels, solar power, telecommunications base stations,... | |
| ELECTRICAL MONITORING & PROTECTION DEVICE | Acrel electrical overload protection devicesprovide solutions for 0.4kv-35kv power distribution system, which include programmable panel energy met... | |
| MICROGRID ENERGY MANAGEMENT SYSTEM | Under the threat of global energy shortage and the urgency to curb environmental pollution, the demand for energy conservation and emission reducti... | |
| POWER QUALITY DEVICE | Acrel power quality equipment is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement eq... |
Same products
| RIELLO Original Gas Burner 40 RHE FS10 Burner | Seller: Hebei QianYue Heat Energy Technology Co., LTD | RIELLO Original Gas Burner 40 RHE FS10 Burner The Riello 40 FS series of one-stage gas burnersis... | |
| Nitrous Oxide, N2O Specialty Gas | Seller: Chengdu Taiyu Industrial Gases Co., Ltd | , also known as nitrous oxide, is an inorganic substance that is stable at room temperature, has ... | |
| Sulfuryl Fluoride, SO2F2 Industrial Gas | Seller: Chengdu Taiyu Industrial Gases Co., Ltd | is an inorganic compound. It is a colorless, odorless and toxic gas under normal temperature and ... | |
| Ammonia, NH3 Industrial Gas | Seller: Chengdu Taiyu Industrial Gases Co., Ltd | is a colorless gas with a strong pungent odor and is corrosive. Ammonia is an important chemical ... | |
| Ethylene, C2H4 Specialty Gas | Seller: Chengdu Taiyu Industrial Gases Co., Ltd | Ethylene is a colourless,with a sweet odour. Ethylene is one of the chemical products with the la... |