High-Precision Material Thermal Conductivity Tester (Guarded Hot Plate Heat Flow Meter Method)
High-Precision Material Thermal Conductivity Tester (Guarded Hot Plate Heat Flow Meter Method) is a fully automated thermal property testing system designed for accurate measurement of thermal conductivity and thermal resistance using the internationally recognized heat flow meter principle. The instrument applies a stable controlled temperature to one side of the specimen, allowing heat to transfer through the material to a cooled surface, while the transmitted heat flux is precisely measured to calculate thermal conductivity and thermal resistance. Equipped with imported sensors and computer-based control and data processing, the system delivers high accuracy, strong reliability, and excellent repeatability, especially for low thermal conductivity materials.
Application
TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:
Thermal insulation materials
Plastics and polymer-based materials
Rubber and elastomer materials
Aerogel panels and advanced insulation boards
Vacuum glass and building energy-saving materials
Solid materials and powder materials (with appropriate sample configuration)
The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.
Standards
The instrument is designed and operated in accordance with the following international and national standards:
GB/T 10295-2008
Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method
ASTM E1530
Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique
ASTM C518-04
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Parameters
| Item | Specification |
|---|---|
| Thermal conductivity range (low range) | 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K) |
| Thermal conductivity range (extended) | 0.001 – 300 W/m·K |
| Measurement accuracy | ±1% |
| Sample size | 50 × 50 to 300 × 300 mm |
| Maximum sample thickness | ≤ 50 mm |
| Optional sample sizes | 600 × 600 mm, 800 × 600 mm (customized) |
| Applicable sample form | Solid materials, powder materials |
| Test duration | 15 – 20 min |
| Hot plate temperature range | Room temperature to 99.9 °C (standard) |
| Optional hot plate range | Room temperature to 499.9 °C or higher (by agreement) |
| Hot plate control accuracy | 0.1 °C |
| Cold plate temperature range | 0 – 99.9 °C (standard); –10 – 99.9 °C optional |
| Cold plate temperature control | Water-cooled, precision constant-temperature bath |
| Cold plate control accuracy | 0.1 °C |
| Pressure range | 0 – 1000 N |
| Pressure resolution | 0.1 N |
| Thickness measurement range | 0 – 50 mm |
| Thickness resolution | 0.1 μm |
| Heat flow sensor | Imported original heat flow meter |
| Test operation | Fully automatic computer-controlled testing and data storage |
| Power supply | AC 220 V / 50 Hz |
Features
Guarded hot plate heat flow meter method for steady-state thermal measurement
High sensitivity for low thermal conductivity materials, resolution down to 0.1 mW/m·K
Imported heat flow sensors ensuring stable and reliable performance
Computer-controlled temperature regulation and pressure loading
Automatic thickness measurement with high resolution
Excellent accuracy, repeatability, and long-term measurement stability
Automatic data acquisition, analysis, storage, and report generation
Suitable for both solid and powder materials
Accessories
Main testing unit
Thermal analysis software (Chinese and English versions)
HX-1005 precision low-temperature constant-temperature water bath (0.01 °C accuracy)
Computer (user-selectable)
Calibration reference sample
在线联系供应商
Other supplier products
| Qinsun UV-master | In response to the climate resistance testing requirements for outdoor textiles, this equipment can simulate outdoor climate conditions and accel... | |
| Spectrophotometer | Standard CIE No.15. ISO 7724-1: Meets international colorimetry and spectral measurement standards. ASTM E1164. DIN 5033: Compliant with industri... | |
| Cleanliness Analysis System | Production: The cleanliness analysis system fully complies with the requirements of standards such as VDA19.1 - 2015. ISO16232. ISO4406. ISO4407. ... | |
| Monomer combustion test device for building materials | Meet the standard Comply with GB/T 20284 standard requirements "Building materials or products of the single combustion test" EN13823 "Monomer Co... | |
| Desktop Xenon lamp aging test chamber | TheXenon lamp aging test chamberis a photoaging tester for large-capacity textile testing. With additional sample light frame, temperature sensor a... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |