PV Module Ammonia Resistance Test Chamber
Applications
The Photovoltaic Ammonia Test Chamber is a testing device designed to evaluate the corrosion resistance of photovoltaic modules in ammonia environments, ensuring their long-term stable operation in harsh conditions such as industrial or agricultural settings.
Standards
IEC 62716: Photovoltaic (PV) modules—Ammonia corrosion testing (The core standard for this equipment).
IEC 61701: Salt mist corrosion testing of photovoltaic (PV) modules.
IEC 60068-2-52: Environmental testing—Part 2-52: Tests—Test Kb: Salt mist, cyclic (sodium chloride solution).
GB/T 2423.17 / GB/T 2423.18: Environmental testing for electric and electronic products—Salt mist testing methods.
IEC Draft 82/722/CDV: Specific requirements for integrated salt mist and ammonia gas exposure sequences.
Features
This equipment can independently perform all test procedures required by IEC 61701 and IEC Draft Standard 82/722/CDV. Specifically, spray testing at severity levels 1-6. damp heat storage, standard atmospheric environment testing, and sample cleaning phases are all completed within the NaCl corrosion chamber. Ammonia spray testing, damp heat storage, spray washing, and drying can all be performed within the NH3 corrosion chamber.
Parameters
| Item | Specifications |
|---|---|
| NH₃ Concentration | 0–10000 ppm (adjustable) |
| Ammonia Concentration Resolution | ±1 ppm |
| Temperature Control Range | 15°C ~ 70°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Deviation | ≤ ±1.0°C |
| Temperature Uniformity | ≤ ±2°C |
| Humidity Control Range | 40% ~ 100% RH (adjustable) |
| Humidity Deviation | ≤ ±2% RH |
| Humidity Uniformity | ≤ ±3% RH |
| Test Accuracy | ±2% |
Accessories
1.Ammonia Gas Dosing System: Precision mass flow controllers for accurate gas injection.
2.Ammonia Concentration Sensor: High-precision electrochemical or laser-based gas detectors.
3.Specimen Racks: Non-reactive, adjustable holders designed to support full-sized PV modules at standard angles.
4.Exhaust Scrubber Unit: A chemical neutralization system to safely treat ammonia-laden air.
5.NaCl Spray Module: Integrated nozzles and reservoir for salt mist phases (Standard Severity 1-6).
6.Deionized Water Rinse: Internal spray bars for automated sample cleaning between test stages.
Test Procedures
1.Preparation
Sample Preparation: Clean samples and secure them on the sample rack, ensuring they do not touch each other.
Solution Preparation: Prepare a 5% NaCl solution (pH 6.5-7.2) according to the standard.
2.Power-On Test
Power Connection: Connect the power supply and turn on the main switch.
3. Test Operation
Start Test: After confirming parameters are correct, press the “Start” button.
Spray Inspection: Once temperature is reached, the spray system will automatically activate. Observe spray uniformity.
4. Test Completion
Shutdown Procedure: Turn off the spray switch. Allow cooling to below 40°C before disconnecting power.
Sample Removal: Remove specimens for corrosion assessment.
在线联系供应商
Other supplier products
| Battery abuse testing chamber for lithium-ion battery manufacturers | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Battery Energy Storage Systems Thermal runaway evaluation of commercial batte... | |
| MST Medical Compression Stocking Tester,compression sock tester | The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the compression performance, elasticity, and durabili... | |
| Safety Helmet Impact Acceleration Tester | Purpose This instrument is suitable for impact - collision tests of helmets. It is a testing instrument used to evaluate the impact - resistance p... | |
| Face Mask Airflow Resistance Measurement tester | Standards: GB19083-2010 technical requirements for medical protective masks Applications: Quality control in production process. Testing in res... | |
| Safety Helmets Against Molten Metal Splashing Tester | Standard GB/T 2812-XXXX: Safety Helmets – Test Methods for Molten Metal Resistance (Draft Standard) GB 2811-2019: Head Protection – G... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |