High-Precision Multi-Functional Thermal Property Testing System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The platform supports internationally recognized absolute measurement standards, including:

(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method

(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source

(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials

(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method

(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids

(6) ASTM D5334: Transient line-source probe method

(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique

Parameters

MethodTPSTHWMTPSTLS
Applicable Materials Solids, pastes, powders Liquids, phase-change materials Solids, pastes, powders Soil, pastes, polymers
Measurement Module 3D bulk, anisotropic, plate, thin film; general: specific heat Bulk 3D bulk, anisotropic, plate; 1D standard Bulk
Thermal Conductivity (W/m·K) 0.01–500 0.01–2 0.03–500 0.1–8
Thermal Diffusivity (mm²/s) 0.01–300 Up to 0.5 0.01–300 Not applicable
Volumetric Heat Capacity (MJ/m³·K) Up to 5 Up to 5 Up to 5 Not applicable
Thermal Effusivity (W·s½/m²·K) 20–40000 Not applicable 20–40000 Not applicable
Sample Size (mm mL) Ø10 or square 20 mL Ø25 or square
Sample Thickness (mm) ≥0.05 Not applicable ≥0.1 Probe length 100
Maximum Sample Size Unlimited Unlimited Unlimited Unlimited
Test Time (s) 2–160 1 2–160 180
Accuracy (Thermal Conductivity) 5% 2% 5% 5%
Repeatability (Thermal Conductivity) 2% 1% 2% 2%
Temperature Range (°C) 0–300 / −75–300 −50–200 0–100 / −50–200 −40–100
Sample Configuration Symmetric / asymmetric Insert type Asymmetric (single-sided) Insert type
Supported Standards ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 ASTM D7896 ISO 22007-7 ASTM D5334. ASTM D5930

Features

Absolute measurement methods with no calibration materials required

Multiple transient techniques integrated on a single platform

Direct measurement of thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity

Suitable for solids, liquids, pastes, powders, and soil

Raw data–based calculation improves traceability and measurement reliability

Accessories

(1) TPS sensors for solids, pastes, and powders

(2) THW sensors for liquid measurements

(3) MTPS sensors for single-sided solid measurements (optional)

(4) TLS probe sensors for soil and polymer testing (optional)

(5) Dedicated sample holders and probe assemblies

Test Procedures

Select the appropriate transient method and sensor based on sample type.

Prepare the sample according to the required geometry and configuration.

Position the sensor in contact with or inserted into the sample.

Apply electrical current to the sensor to generate controlled heating.

Record the temperature rise as a function of time.

Calculate thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity directly from the transient response data.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Compression performance testing machine
Compression performance testing machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Compression Tester STD-FB3-A is suitable for a wide range of flexible and ...
PPE helmet strap tensile testing machine for ISO head protection standards
PPE helmet strap tensile testing machine for ISO head protection standards Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Apply a certain initial load to the helmet strap system for a ce...
Solid Combustion Rate Tester
Solid Combustion Rate Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This product complies with "Recommendations on the Transport of Dange...
Tibial Tray Fatigue Testing Machine
Tibial Tray Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total ...
Automatic Reaction Calorimeter
Automatic Reaction Calorimeter Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB 51283 GB/T 22232 GB/T 17802 SN/T 3078.1 Product Features 1. It offers th...
供应产品

Same products

Laser Cutting Machines
Laser Cutting Machines 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen