ISO 834 Horizontal Fire Resistance Furnace Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Item | Specification |
|---|---|
| Number of Burners | 12 proportional flat-flame burners (6 on each side, 5 m furnace length) |
| Operating Temperature | Maximum test temperature 1250 °C |
| Design Temperature | 1350 °C |
| Combustion Mode | Low-speed proportional flat-flame diffusion combustion |
| Gas & Air Pressure | ≤ 4000 Pa |
| Flame Length | ≤ 500 mm |
| Furnace Temperature Measurement Points | 9 points |
| Thermocouple Sleeve Extension | ≥ 25 mm |
| Temperature Accuracy | < ±15 °C |
| Furnace Pressure Measurement | T-type probes, accuracy ±2 Pa, 3 points |
| Data Acquisition Rate | 3 times per second |
| Fuel Gas | Liquefied petroleum gas |
| Equipment Dimensions | 8 m (W) × 8 m (L) × 2.5 m (H) |
| Power Supply | AC 380 V, 70 kW |
| Equipment Weight | Approx. 5 t |
Features
Robust Furnace Structure
Frame-type enclosure with refractory bricks and high-temperature insulation fiber ensures thermal stability while minimizing heat loss to the surrounding environment.
Safe and Accessible Operation Design
Steel platforms are installed around the furnace for convenient operator access and maintenance.
Advanced Combustion Safety Protection
Automatic flame-out detection with visual and audible alarms; the system cuts off LPG supply to the affected burner while other burners continue operating.
Reliable Gas Supply and Control System
Equipped with gas solenoid valves, proportional valves, pressure transmitters, ball valves, regulators, and filters to ensure stable and safe gas delivery.
Precise Air–Fuel Ratio Control
Combustion air is supplied by a dedicated blower with frequency inverter for airflow adjustment, ensuring optimal combustion conditions.
Independent Control System
Dedicated control components manage combustion processes and simulate standard fire curves accurately.
Automatic Temperature Curve Tracking
Real-time comparison between actual furnace temperature and the preset fire curve, with automatic correction via burner output adjustment.
Comprehensive Data Recording
All automatic control and test data are stored in the computer system for traceability and accuracy verification.
Accessories
(1) Proportional flat-flame burners
(2) Gas solenoid valves and proportional valves
(3) Combustion air blower with frequency inverter
(4) Gas pressure regulators and filters
(5) T-type furnace pressure probes
(6) High-temperature exhaust fan with inverter
(7) Programmable logic controller (PLC) system
(8) Computer-based control and data acquisition system
Test Procedures
Install the horizontal test specimen securely in the furnace opening according to the test configuration.
Set test parameters through the control system, including fire curve, test duration, and safety limits.
Start the combustion system and initiate the standard fire exposure.
Monitor furnace temperature, pressure, and combustion status in real time via the computer interface.
The control system automatically adjusts burner output to maintain the specified temperature curve.
Upon test completion, shut down the gas supply and allow the furnace to cool before specimen removal.
在线联系供应商
Other supplier products
| Helmet Strap Tensile Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The helmet strap tensile testing machine is designed to simulate tensile, impact, and durab... | |
| Automotive Seat Headrest Tester | Load Bearing & Safety Strength Test Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Dedicated design for static strength testing of automotive head... | |
| AI-powered catheter burst pressure tester equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The catheter burst pressure tester is a key device used to evaluate catheter ... | |
| Helmets Designated Protection Areas Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The helmet designated protection area testing device is a piece of equipment used to mark t... | |
| Solar Simulation Chamber 丨Solar Simulation Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Full-spectrum precise reproduction a 4500 Wwater-cooledxenon ar... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |