Parameters
| Item | Specification |
|---|---|
| Number of Burners | 12 proportional flat-flame burners (6 on each side, 5 m furnace length) |
| Operating Temperature | Maximum test temperature 1250 °C |
| Design Temperature | 1350 °C |
| Combustion Mode | Low-speed proportional flat-flame diffusion combustion |
| Gas & Air Pressure | ≤ 4000 Pa |
| Flame Length | ≤ 500 mm |
| Furnace Temperature Measurement Points | 9 points |
| Thermocouple Sleeve Extension | ≥ 25 mm |
| Temperature Accuracy | < ±15 °C |
| Furnace Pressure Measurement | T-type probes, accuracy ±2 Pa, 3 points |
| Data Acquisition Rate | 3 times per second |
| Fuel Gas | Liquefied petroleum gas |
| Equipment Dimensions | 8 m (W) × 8 m (L) × 2.5 m (H) |
| Power Supply | AC 380 V, 70 kW |
| Equipment Weight | Approx. 5 t |
Features
Robust Furnace Structure
Frame-type enclosure with refractory bricks and high-temperature insulation fiber ensures thermal stability while minimizing heat loss to the surrounding environment.
Safe and Accessible Operation Design
Steel platforms are installed around the furnace for convenient operator access and maintenance.
Advanced Combustion Safety Protection
Automatic flame-out detection with visual and audible alarms; the system cuts off LPG supply to the affected burner while other burners continue operating.
Reliable Gas Supply and Control System
Equipped with gas solenoid valves, proportional valves, pressure transmitters, ball valves, regulators, and filters to ensure stable and safe gas delivery.
Precise Air–Fuel Ratio Control
Combustion air is supplied by a dedicated blower with frequency inverter for airflow adjustment, ensuring optimal combustion conditions.
Independent Control System
Dedicated control components manage combustion processes and simulate standard fire curves accurately.
Automatic Temperature Curve Tracking
Real-time comparison between actual furnace temperature and the preset fire curve, with automatic correction via burner output adjustment.
Comprehensive Data Recording
All automatic control and test data are stored in the computer system for traceability and accuracy verification.
Accessories
(1) Proportional flat-flame burners
(2) Gas solenoid valves and proportional valves
(3) Combustion air blower with frequency inverter
(4) Gas pressure regulators and filters
(5) T-type furnace pressure probes
(6) High-temperature exhaust fan with inverter
(7) Programmable logic controller (PLC) system
(8) Computer-based control and data acquisition system
Test Procedures
Install the horizontal test specimen securely in the furnace opening according to the test configuration.
Set test parameters through the control system, including fire curve, test duration, and safety limits.
Start the combustion system and initiate the standard fire exposure.
Monitor furnace temperature, pressure, and combustion status in real time via the computer interface.
The control system automatically adjusts burner output to maintain the specified temperature curve.
Upon test completion, shut down the gas supply and allow the furnace to cool before specimen removal.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Aluminum Tube Internal Coating Continuity Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Aluminum Tube Internal Coating Continuity Tester is an important device specifically de... | |
| Commercial Liquid Penetration Sliding Test Machine | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The G373 Liquid Sliding Penetration Comprehensive Performance Tester is a pre... | |
| SATRA TM55 Leather Low-Temperature Flexing Tester Manufacturer | Factory Direct Sale | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features 1. Inner and Outer Tank Material: Stainless Steel #304 2. Controll... | |
| Laminoplasty Plate System Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F2193-18: Specifies static/fatigue testing protocols for spinal constructs, ... | |
| CE certified mask fit tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Qinsun PortaCount Respirator Fit Tester assesses the overall integrity of... |
Похожие товары
| Laser Cutting Machines | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ... | |
| Precision Laser Micromachining Machine | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ... | |
| Ultrafast Laser Systems | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi... | |
| Industrial Laser Equipment Manufacturer | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan... | |
| Common Rail Injector Valve F00R J02 012 | Продавец: 868983 | Common Rail Injector Valve F00R J02 012 David Chen |