ISO 834 Horizontal Fire Resistance Furnace Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Parameters

ItemSpecification
Number of Burners 12 proportional flat-flame burners (6 on each side, 5 m furnace length)
Operating Temperature Maximum test temperature 1250 °C
Design Temperature 1350 °C
Combustion Mode Low-speed proportional flat-flame diffusion combustion
Gas & Air Pressure ≤ 4000 Pa
Flame Length ≤ 500 mm
Furnace Temperature Measurement Points 9 points
Thermocouple Sleeve Extension ≥ 25 mm
Temperature Accuracy < ±15 °C
Furnace Pressure Measurement T-type probes, accuracy ±2 Pa, 3 points
Data Acquisition Rate 3 times per second
Fuel Gas Liquefied petroleum gas
Equipment Dimensions 8 m (W) × 8 m (L) × 2.5 m (H)
Power Supply AC 380 V, 70 kW
Equipment Weight Approx. 5 t

Features

Robust Furnace Structure

Frame-type enclosure with refractory bricks and high-temperature insulation fiber ensures thermal stability while minimizing heat loss to the surrounding environment.

Safe and Accessible Operation Design

Steel platforms are installed around the furnace for convenient operator access and maintenance.

Advanced Combustion Safety Protection

Automatic flame-out detection with visual and audible alarms; the system cuts off LPG supply to the affected burner while other burners continue operating.

Reliable Gas Supply and Control System

Equipped with gas solenoid valves, proportional valves, pressure transmitters, ball valves, regulators, and filters to ensure stable and safe gas delivery.

Precise Air–Fuel Ratio Control

Combustion air is supplied by a dedicated blower with frequency inverter for airflow adjustment, ensuring optimal combustion conditions.

Independent Control System

Dedicated control components manage combustion processes and simulate standard fire curves accurately.

Automatic Temperature Curve Tracking

Real-time comparison between actual furnace temperature and the preset fire curve, with automatic correction via burner output adjustment.

Comprehensive Data Recording

All automatic control and test data are stored in the computer system for traceability and accuracy verification.

Accessories

(1) Proportional flat-flame burners

(2) Gas solenoid valves and proportional valves

(3) Combustion air blower with frequency inverter

(4) Gas pressure regulators and filters

(5) T-type furnace pressure probes

(6) High-temperature exhaust fan with inverter

(7) Programmable logic controller (PLC) system

(8) Computer-based control and data acquisition system

Test Procedures

Install the horizontal test specimen securely in the furnace opening according to the test configuration.

Set test parameters through the control system, including fire curve, test duration, and safety limits.

Start the combustion system and initiate the standard fire exposure.

Monitor furnace temperature, pressure, and combustion status in real time via the computer interface.

The control system automatically adjusts burner output to maintain the specified temperature curve.

Upon test completion, shut down the gas supply and allow the furnace to cool before specimen removal.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Dust Chamber MIL STD 810
Dust Chamber MIL STD 810 Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits Themil std 810 test chamberis made ofSUS304. which can withstand the...
High Accuracy Scratch Resistance Tester KK-02 for Tribology Research
High Accuracy Scratch Resistance Tester KK-02 for Tribology Research Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 19252 — Plastics — Determination of scratch resist...
Bus Seat Durability Testing Machine
Bus Seat Durability Testing Machine Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bus Seat Tester is designed to evaluate the durability, strength, and fat...
Coatings Shear Fatigue Tester
Coatings Shear Fatigue Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0988.13-2017 (China): Specifies shear fatigue testing protocols for coatings...
Automatic sandbag load testing equipment
Automatic sandbag load testing equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The machine is widely used for mechanical performance testing and structural v...
All supplier products

Same products

Gasket for Plate Heat Exchanger
Gasket for Plate Heat Exchanger Seller: Hengshui Hongcan Import and Export Trading Co., Ltd The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ...
Energy Saver
Energy Saver Seller: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
ER1100 Aluminum Welding Wire
ER1100 Aluminum Welding Wire Seller: 868776 The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ...
air conditioner
air conditioner Seller: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...