HEPA ULPA Filter Scanning Test System, EN 1822 Filter Integrity Tester Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Parameters

ParameterUnitValue
Test Flow Rate m³/h 120 – 5000
Differential Pressure Measurement Pa 1000
Test Sample Dimensions mm Max 1830 × 1220 × 300
Aerosol Operating Medium – DEHS, PSL
Gas/Air Supply bar 6
Power Supply – 3 × 400 VAC, 100 A

Accessories

AccessoryQuantity
Filter Media Test Instrument 1
Filter Adapter 1
Test System Software 1

Test Principle

Sample Installation: The filter is mounted in the filter holder, ensuring a secure fit.

Aerosol Generation & Flow: Aerosol (DEHS or PSL) is introduced at a controlled volume through the filter.

Leakage and Efficiency Measurement: Downstream particle concentration is measured via particle counters to calculate overall filtration efficiency and identify potential leaks.

Automated Data Collection: PC-controlled software records upstream and downstream particle counts and calculates efficiency and leakage locations.

Operation Instructions

System Startup:

- Configure and start all devices, including aerosol generator, particle counters, and airflow system.

- Install filter adapter according to sample dimensions.

Testing Process:

- Launch test; the system scans the filter using multiple probes, measuring leakage and overall efficiency automatically.

Data Recording & Reporting:

- Software generates a standard-compliant report, including efficiency and leak position.

Experimental Procedure

Preparation Stage:

- Verify all devices are operational.

- Install filter in the appropriate adapter.

Testing Stage:

- System conducts automated scanning and efficiency/leakage measurement.

Result Analysis & Report Generation:

- Test results are automatically compiled and saved in the software, including filter efficiency, potential leaks, and compliance with standards.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

meChanical scratch tester for coating adhesion testing
meChanical scratch tester for coating adhesion testing Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 23989-2009 – Determination of scratch resistance of coatings (2)...
Smoke Detector Test Tunnel Manufacturer | EN 54 & UL 268 Fire Alarm Testing Equipment
Smoke Detector Test Tunnel Manufacturer | EN 54 & UL 268 Fire Alarm Testing Equipment Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters UnitSpecification Tem...
Particle Strength Tester
Particle Strength Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D4179: Standard Test Method for Single-Pellet Pressure Resistance of Catal...
Automatic wire guide pushing force apparatus
Automatic wire guide pushing force apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The guidewire pushing force tester is a precision testing tool in the medical...
Carpet Taber Abrasion Testing Machine EN 1307 Factory Price
Carpet Taber Abrasion Testing Machine EN 1307 Factory Price Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features You can evaluate carpet abrasion resistance using standardized fric...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...