EN 779 Turbine Filter Test System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system complies with:

(1) ISO 29461-1 – Air filter performance, test methods.

(2) ISO 29461-2 – Air filter performance, gas adsorption test.

(3) ISO/AWI 29461-4 – Air filter performance, salt removal efficiency.

(4) ISO 16890-2 – Air filter classification and testing for general air filters.

(5) ISO 16890-3 – Gravimetric efficiency determination.

(6) ISO 16890-4 – Fractional efficiency and dust holding capacity.

(7) ISO/DIS 29461-7 – Gas turbine filter testing guidance.

(8) ISO 12103-1 – Fine test dust (A2) for filter performance.

(9) ASHRAE 52.2 – Air filter testing using airflow and particle size distribution.

(10) EN 779 – Requirements for high-efficiency air filters.

(11) GB/T 12103-1 & GB/T 12103-2 – Test dust and adsorption methods.

(12) GB/T 18801-2015 – Performance testing for air purifiers.

Principle

A defined volume flow rate is sucked through a HEPA intake filter, the attached test duct and the safety filter. The test system is composed of 6 sections: aerosol inlet, upstream measurement, specimen holder, downstream measurement, safety filter and flow rate measurement. The measurement sections are equipped with ports for the aerosol characterization and the determination of the pressure drop.

Technical data

ParameterUnitValue
Test flow rate m³/h 800 … 11.000
Test aerosol DEHS, KCl, Ashrae, ISO 12103-A2 (AC fine), ISO 12103-A4 (AC coarse)
Test specimen dimensions 610 × 610 mm (pocket and cassette filters); diameter ≤ 400 mm, length ≤ 1500 mm (filter cartridges)
Differential pressure of test specimen Pa max. 2000
Compressed air supply (operating gas/air) bar min. 5 (17 m³/h)
Water supply (operating medium) bar min. 3
Power supply 3 × 400 VAC, 125 A, 50 Hz
Air circulation % 0 … 100
Sensors (others) Temperature, relative humidity, air pressure
System dimensions (W × H × D) m 4.6 × 1.7 × 14.0

Features

Circulation mode for control of the test parameters temperature and humidity

Injection of different aerosols (NaCl, KCl, DEHS) into an optimal flow profile

Automated feeding of water droplets and supersaturated vapour

High level of automation, mostly automated test runs with complete operator guiding

Gas-Tight Test Ducts: Ensure accurate particle and gas measurements.

Modular Design: Accommodates different filter types and sizes.

High Automation: Software-driven sequences with automatic data acquisition.

Multi-Medium Testing: Supports various aerosols and pollutant gases.

Standardized Reporting: Automatically generates reports including differential pressure, dust loading, fractional efficiency, and salt removal efficiency.

Environmental Control: Built-in temperature and humidity sensors allow testing under controlled conditions.

Accessories

Accessory / ConsumableQuantityDescription
DEHS Aerosol Generator 1 For fine aerosol particle testing
ASHRAE Dust Generator 1 For standardized dust loading tests
Optical Particle Counters 2 0.2–10 μm, four channels
H14 Air Filter 1 For system calibration
Temperature & Humidity Sensors 2 Monitor test environment
Gas Analyzers 3 Measure NO₂, H₂SO₄, and other gases

Operation Instructions

Safety:

Confirm power, gas, and water connections before testing.

Avoid direct exposure to aerosols and gases; ensure good ventilation.

Wear protective equipment when handling hazardous gases.

Standard-Specific Testing:

The system adjusts test conditions automatically according to ISO 16890. ISO 29461-2. or other relevant standards.

After testing, the system generates standardized reports.

Test Procedure

Preparation:

Select the appropriate filter adapter and install the sample.

Configure test airflow, aerosol concentration, humidity, and temperature per standard requirements.

Testing:

Start the automated system; aerosol and gas injection begins.

The system continuously records differential pressure, dust loading, and fractional efficiency.

Data Analysis & Reporting:

After testing, the software analyzes collected data.

Generate reports including pressure curves, dust loading, fractional efficiency, and salt removal efficiency.

Maintenance Information

Regularly inspect aerosol and gas generators for proper operation.

Calibrate sensors periodically for accuracy.

Keep the system clean and free of particulate build-up.

Ensure all safety interlocks and ventilation systems are functional.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Intramedullary Nails Internal-fixation Pull-out Force Tester
Intramedullary Nails Internal-fixation Pull-out Force Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F543: Standard specification for metallic medical bone screws (dynamic loadi...
Apparel Drying Dynamics Control System
Apparel Drying Dynamics Control System Whats/App: +86 156 1874 6768 Web: standard-groups.com The Textile Drying Time Tester is a precision instrument designed to measure evaporation ra...
High Temperature Tribometer
High Temperature Tribometer The High-Temperature Tribology Tester is designed to perform friction and wear tests using ball-on-disk and pin-on-disk configurations. It is suita...
Suture Needle Penetration and Bending Strength Tester
Suture Needle Penetration and Bending Strength Tester The Suture Needle Penetration and Bending Strength Tester is a device used to test the penetration performance and strength of medical suture needl...
Photovoltaic module backplane peeling strength testing machine
Photovoltaic module backplane peeling strength testing machine The Photovoltaic Module Backplane Peeling Strength Testing Machine is a specialized device designed to evaluate the peeling strength of photovoltai...
供应产品

Same products

ISO 29463 HEPA/ULPA filter performance testing System
ISO 29463 HEPA/ULPA filter performance testing System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli...
High-Precision ISO 16890 Filter Media Test Rig for R&D and QC
High-Precision ISO 16890 Filter Media Test Rig for R&D and QC 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com...
ISO 12103 Cleanable Filter Media Test System
ISO 12103 Cleanable Filter Media Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...
Advanced Vehicle and Aircraft Air Intake Filter Test System
Advanced Vehicle and Aircraft Air Intake Filter Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...
EN 779 Turbine Filter Test System
EN 779 Turbine Filter Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...