Photovoltaic module insulation resistance tester/ Solar panel insulation tester/IEC 61215 insulation resistance testing

Standard

  • IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval
  • UL 61730: Safety Standard for Photovoltaic Modules
  • ISO 17025: General Requirements for the Competence of Testing and Calibration Laboratories
  • CE Certification(Conformité Européenne)

Product Advantages

  1. Dual-Parameter Precision
    • Simultaneous Insulation Resistance & Leakage Current Testing: Eliminates the need for separate instruments.
    • 100 kΩ–10 TΩ Range: Covers residential to utility-scale PV module testing (10⁵ Ω–10¹³ Ω).
  2. Ultra-High Accuracy
    • <1 GΩ: ±1%, 1–10 GΩ: ±3%, ≥10 GΩ: ±5%: Ensures compliance with IEC 61215’s stringent insulation requirements.
    • 1% Voltage Accuracy: 1.0–1,000 VDC output with 0.1 V/1 V step adjustments.
  3. Multi-Speed Testing
    • 55 Readings/Second (High-Speed Mode): Ideal for production line QC.
    • 3 Readings/Second (Full-Speed Mode): Maximizes measurement resolution for R&D.
  4. Safety First
    • 30 mA Max Charging Current: Prevents arc-flash risks during high-voltage testing.
    • Overvoltage Protection: 1,200 VDC surge rating for transient stability.
  5. Smart Diagnostics
    • AI-Powered Failure Analysis: Flags insulation breakdown patterns and PID risks.
    • Auto-Ranging: Optimizes test voltage (50–1,000 VDC) based on module specs.

Product Features

  • Non-Destructive Testing (NDT): Preserves sample integrity with <10 nA leakage current.
  • Laser-Guided Probe Placement: Ensures precise contact on textured module surfaces.
  • Dynamic Calibration: Auto-corrects for temperature/humidity drift during testing.
  • Emergency Shutoff: Dual redundant safety circuits with E-stop button.
  • Glovebox Compatibility: Oxygen/moisture levels <0.1 ppm for sensitive chemistries.

Technical Parameters

ParameterSpecification
Insulation Resistance 100 kΩ–10 TΩ (10⁵ Ω–10¹³ Ω)
Leakage Current 10 nA–20 mA (auto-ranging)
Test Voltage 1.0–1,000 VDC (0.1 V steps <100 V, 1 V steps ≥100 V)
Voltage Accuracy ±1% (at 1,000 VDC)
Measurement Speed 55/25/3 readings/second (high/medium/full)
Max Charging Current 30 mA ±5 mA
Power Supply 100-240V AC, 50/60Hz (universal adapter)
Dimensions 300mm (W) × 250mm (D) × 150mm (H)
Weight 5 kg (net) / 7 kg (gross)

Accessories Included

  1. Testing Kit:
    • 4x insulated test probes (10 kV rated).
    • 10x alligator clip leads (red/black).
  2. Software Suite:
    • License key forInsulationAI Pro(Windows/macOS).
    • 1-year free access to cloud-based data analytics.
  3. Calibration & Safety:
    • NIST-traceable resistance standard (1 GΩ, 10 GΩ).
    • Explosion-proof gloves (Class 00, 3 pairs).
  4. Maintenance Kit:
    • Spare fuses and probe tips.
    • Cleaning solution for optical components.
  5. Documentation:
    • Multilingual quick-start guide (printed + digital).
    • Compliance certificates for IEC/UL/ISO standards.


在线联系供应商

至: 标准集团
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

End-face rotary friction and wear testing machine
End-face rotary friction and wear testing machine Main uses: The end-face rotary friction and wear testing machine is mainly used to evaluate the wear resistance and tribological behavior of mater...
G645 leather shoe hook stiffness testing machine
G645 leather shoe hook stiffness testing machine Leather shoe hook stiffness tester is suitable for measuring the longitudinal bending stiffness of leather shoe hook. The principle is to fix the h...
Automatic open flash point tester
Automatic open flash point tester Product Introduction: The instrument can automatically test the flash point and ignition point of petroleum products (the ignition point of oil ex...
Medical Mask Differential Pressure Tester YY 0469-2011 YY/T0969-2013
Medical Mask Differential Pressure Tester YY 0469-2011 YY/T0969-2013 Standards: YY 0469-2011 YY/T0969-2013 EN 14683:2014 Annex C ASTM F2100 Product Information: Medical Mask Differential Pressure Tester also calle...
Mask synthetic blood penetration tester
Mask synthetic blood penetration tester Standards: GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood. YY/T 0691-2008 Clothin...
供应产品

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 卖方: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer 卖方: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester 卖方: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool 卖方: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester 卖方: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...