Wire Stripping Machine
Common failures and methods ofwire stripping machine.
1. The length of front wire is different.
A. If the clearance is too large for the left transmission line, adjust the left clearance.
B. The straightener is pressed too tightly. Adjust the straightener adjustment knob.
C. The catheter is not aimed at the center of the knife, and it will adjust the catheter to the center of the blade.
2. The length of the back wire is different.
There is too much clearance for the right transmission line. Adjust the right clearance adjustment disc to the right clearance.
3. The total length is inconsistent with the actual setting parameters.
A. It is longer than the set length, which is due to the systematic error in the mechanical transmission, you need to reduce the value of "L" in the mode.
B. It is shorter than the set length. Because the gap and pressure adjustment between the two wheels of the left transmission line is not suitable, and the value of "L" should be increased in the mode.
C. The length is not consistent because of the failure of the straightener to send the line. It is necessary to adjust the pressure of the right transmission line to the suitable clearance, keep the straightener sent smoothly.
4. The front-end incision is inclined.
It is due to the improper positioning of the catheter. Align the tube with the center of the knife edge.
5. The line head is stripped out of normal while the line end is normal. Some of the incisions are inclined, some of the line cores are cut.
Because the position of the tube is too close to the blade. Adjust the position of the tube, so that the distance between the front end of the tube and the blade is greater than the distance from the line tail (A).
6. The front or the back is cut off in the same bundle line.
Because the edge of the blade is too blocked by too much wire skin and clean it with a brush.
7. The insulation skin is overlaid.
Because there is the excessive pressure on the left and right transmission line. Reduce the left and right pressure wheel.
8. Stripping or stripping in the middle, the length L is qualified, but the size of A.B does not meet the requirements of setting.
A. The wire quality is not qualified, the insulation layer is too loose to the core wire, and the qualified conductor can be replaced.
B. The insulation layer is too soft which is pushed to deformation in machining molting process. The prototype cannot be recovered by external. It is the processing method itself that has the inherent defect. Thus reduce the requirements on the accuracy of length.
Other supplier products
|
|
BJ-918B Scrap Cable Wire Stripping Machine |
Operation Video ofBJ-918B Scrap Cable Wire Stripping Machine
BJ-918B scrap wire stripper is the most popular multi-function wire stripping equip... |
|
|
BJ-02E 4 Drivers Wire Cutting Machine |
Operation Video ofBJ-02E 4 Drivers Wire Cutting Machine
Specification ofBJ-02E 4 Drivers
Model: BJ-02E FOUR DRIVERS
Power: AC220/ 50HZ 110V/... |
|
|
Tube Cutting Machine |
Tube Cutting Machine
BJ-02AT Automatic Corrugated Pipe Cutting Machine
* Power supply: AC220V* Voltage: 500W* Weight: 85kg* G.N: 72kg... |
|
|
Pneumatic Wire Stripping Machine |
Pneumatic Wire Stripping Machine
BJ-0320 Magnetic Pneumatic Wire Stripping Machine
* Cable cross section: 0.03 – 2.08 mm² (3... |
|
|
Automaitc Coil Winding Machine |
What are the most common problems with automatic coil winding machine and what are the using techniques?There are four common problems with thecoil... |
供应产品
Same products