No baffle-board ultrasonic heat meter

  1. “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”techniquecharacters

(1)Theflowsensorisnoreflectionstructureusingmeasurementpipeinwallrefection

(2)Theflowmetersensorpipewithoutreflectionplatesupportandbeampiecesistotallystraightthrough,noblocking,nowear.

(3)Theflowmetersensorpipewithoutanyinternalpartwhichremovestheobstructionstowaterflowcausedbythereflectionplate,reflectionplatesupportandbeampiecesoftraditionalbasemeter,lowpressureloss,reducespressurelossoftheheatingdistributionsystem.

(4)Adoptingdualpowersupplytechnologyofbuilt-inbatteryandexternalremotecommunicationsystempowersupplyreducestheremotecommunicationeffectsonbuilt-inbatterylife.

(5)Boththeflowsensorpipeinwallandthetransducersurfaceadoptmetalchemicalanti-foulingdesignanddisposetoensuretheultrasonicsignalintensity.

(6)Featuresemptypipedetection(entersintodormantstateoutofheatingperiod)andautomaticwake-upfunction.

(7)TheprocessorusesMSP430dedicatedchipofAmericanTIcompany,ultra-lowpowerconsumption,modularfunction,lessperipheralcircuit.

(8)TheultrasonicsensordedicateddetectionchipadoptsTDC-GP2/GP21ofGermanyACAMcompany,withhighprecisionmeteringaccuracy.

(9)Adoptingintegratedlowpowerconsumptioncircuitdesignprolongsthebatteryworkinglifewiththeoreticworkinglifeover10years.

(10)ThehighprecisionPT1000platinumresistancepairtemperaturesensoradoptingGermanytemperature-sensingelementandKoreaproductiontechnologysatisfiesthemeteringaccuracyrequirements.

  1. “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”maintechniqueparameters
  2. Structure

·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces

·Temperaturesensor:PT1000temperaturesensorpair

·Opticalinterface,M-businterfacefordatacommunication

  1. Flow
  • Ratedflow:1.5~3.5m³/h
  • Ratedflowandminflowproportionis100.
  1. Temperatureandtemperaturedifference
  • Temperaturemeasurementrange:4~95℃
  • Temperaturedifference:3~90℃
  • Thermalcoefficient:Alongwithinletandoutletwater
  1. Connectionmode
  • Installationposition:inletoroutletasinstructed(optional)
  • Connectiontype:threadedconnection
  • Maxworkingpressure:1.6MPa
  1. Servicecondition
  • Environmentcondition:ClassA
  1. Display
  • Display:LCD,8digits,specialsymbols
  • Dimension:kWh,MJ
  • Resolution

(1)Heat:1kWhor1MJ

(2)Cumulativeflow:0.01m³

(3)Temperature:0.1℃

(4)Temperaturedifference:0.1K

  1. Datastorage
  • Datastorage:ROM
  • Storeatleast18months’data
  1. Intensityandtightness
  • Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
  1. Accuracy
  • MeteringaccuracyisClass2
  1. Pressureloss
  • Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
  1. Powersupply
  • Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
  • Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
  • Workingcurrent:10~40μA
  1. Safetyrequirements
  • Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
  • Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
  • TheenclosureprotectiongradeisIP54
  • Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
  • Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.


在线联系供应商

至: 威海震宇智能科技股份有限公司
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

ultrasonic heat energy meter
ultrasonic heat energy meter ZYultrasonicheatmeterconsistsofflowsensor,temperaturesensorandcalculatorandissimpletoinstall,readandverify.Itisidealforthemeasurementofenergyconsum...
Superconducting radiator
Superconducting radiator Superconductingheattransferisanenergy-savingadvancedtechnologywhichwasfirstlyinventedandappliedinmannedspaceflightbyAmericaaerospaceengineeringandt...
ultrasonic heat energy meter
ultrasonic heat energy meter ZYsplitmechanicalheatmeteradoptsanumberofpatentedtechnologyuniquetoWeihaizhenyuintelligenceandtechnologyCo.,Ltdindomesticandinnovativelydesignsthef...
ultrasonic heat energy meter
ultrasonic heat energy meter ProducttechnicalcharacteristicsarecompliantwiththerequirementsofGJ128-2007ChinaUrbanConstructionIndustryStandardandJJG225-2001NationalHeatMeterVer...
Ultrasonic heat meter
Ultrasonic heat meter ZYultrasonicheatmeterconsistsofflowsensor,temperaturesensorandcalculatorandissimpletoinstall,readandverify.Itisidealforthemeasurementofenergyconsum...
供应产品

Same products

Walk In Environmental Chamber
Walk In Environmental Chamber 卖方: Guangdong ALI Testing Equipment Co,.Ltd Application JOEO Multi-functional walk in environmental chamber is the perfect testing place for ...
Solid Walk In Test Chamber
Solid Walk In Test Chamber 卖方: Guangdong ALI Testing Equipment Co,.Ltd Application: JOEO solid walk in test chamber is an all-welded test chamber with an integrated con...
Compact Walk In Environmental Chamber
Compact Walk In Environmental Chamber 卖方: Guangdong ALI Testing Equipment Co,.Ltd Application JOEO compact walk in environmental chamber is used to test full-size solar panels or ...
Drying Walk In Environmental Chamber
Drying Walk In Environmental Chamber 卖方: Guangdong ALI Testing Equipment Co,.Ltd Application Dry walk in environmental chambers are a special type of walk in environmental chambe...
Walk In Test Chamber For CATL Battery
Walk In Test Chamber For CATL Battery 卖方: Guangdong ALI Testing Equipment Co,.Ltd CATL Battery Walk In Test Chamber JOEO Walk In Test Chamber's temperature cyclic stress screening...