ultrasonic calorimeter
- “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”techniquecharacters
(1)Theflowsensorisnoreflectionstructureusingmeasurementpipeinwallrefection
(2)Theflowmetersensorpipewithoutreflectionplatesupportandbeampiecesistotallystraightthrough,noblocking,nowear.
(3)Theflowmetersensorpipewithoutanyinternalpartwhichremovestheobstructionstowaterflowcausedbythereflectionplate,reflectionplatesupportandbeampiecesoftraditionalbasemeter,lowpressureloss,reducespressurelossoftheheatingdistributionsystem.
(4)Adoptingdualpowersupplytechnologyofbuilt-inbatteryandexternalremotecommunicationsystempowersupplyreducestheremotecommunicationeffectsonbuilt-inbatterylife.
(5)Boththeflowsensorpipeinwallandthetransducersurfaceadoptmetalchemicalanti-foulingdesignanddisposetoensuretheultrasonicsignalintensity.
(6)Featuresemptypipedetection(entersintodormantstateoutofheatingperiod)andautomaticwake-upfunction.
(7)TheprocessorusesMSP430dedicatedchipofAmericanTIcompany,ultra-lowpowerconsumption,modularfunction,lessperipheralcircuit.
(8)TheultrasonicsensordedicateddetectionchipadoptsTDC-GP2/GP21ofGermanyACAMcompany,withhighprecisionmeteringaccuracy.
(9)Adoptingintegratedlowpowerconsumptioncircuitdesignprolongsthebatteryworkinglifewiththeoreticworkinglifeover10years.
(10)ThehighprecisionPT1000platinumresistancepairtemperaturesensoradoptingGermanytemperature-sensingelementandKoreaproductiontechnologysatisfiesthemeteringaccuracyrequirements.
- “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”maintechniqueparameters
- Structure
·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces
·Temperaturesensor:PT1000temperaturesensorpair
·Opticalinterface,M-businterfacefordatacommunication
- Flow
- Ratedflow:1.5~3.5m³/h
- Ratedflowandminflowproportionis100.
- Temperatureandtemperaturedifference
- Temperaturemeasurementrange:4~95℃
- Temperaturedifference:3~90℃
- Thermalcoefficient:Alongwithinletandoutletwater
- Connectionmode
- Installationposition:inletoroutletasinstructed(optional)
- Connectiontype:threadedconnection
- Maxworkingpressure:1.6MPa
- Servicecondition
- Environmentcondition:ClassA
- Display
- Display:LCD,8digits,specialsymbols
- Dimension:kWh,MJ
- Resolution
(1)Heat:1kWhor1MJ
(2)Cumulativeflow:0.01m³
(3)Temperature:0.1℃
(4)Temperaturedifference:0.1K
- Datastorage
- Datastorage:ROM
- Storeatleast18months’data
- Intensityandtightness
- Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
- Accuracy
- MeteringaccuracyisClass2
- Pressureloss
- Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
- Powersupply
- Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
- Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
- Workingcurrent:10~40μA
- Safetyrequirements
- Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
- Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
- TheenclosureprotectiongradeisIP54
- Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
- Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.
Send product request
Other supplier products
| Ultrasonic heat energy meter WITHOUT REFLECTION PLATE | Capability Parameter NominalDiameter(mm) DN15 DN20 DN25 DN32 DN40 Ratedflow(m³/h) 2.5 6 10 MinFlow(m³... | |
| Superconducting heat pipe | Superconducting heat pipe Superconducting heat pipeadoptsasophisticatedtechnologywhichisappliedtoaerospacefield.Onceasectionisheated,throughthehea... | |
| ultrasonic heat meter with no reflection plate | Features: Squareholestraightthroughbasemeter---noblockage,lowpressureloss. Usingthepipewallreflection---stablesignal,lowfailures. Extendedtransduc... | |
| No baffle-board ultrasonic heat meter | Structure ·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces ·Temperaturese... | |
| Pt1000 heat meter temperature sensor | HeatMeterTemperatureSensorPair Temperaturesensorpairarerespectivelymountedonthepipeoftheheattransferloopinletandoutlet,whiletheflowsensorismountedo... |
Same products
| Custom Stainless Components for OEM Applications | Seller: Yongjia County Yaokang Technology Co., Ltd. | Our stainless steel float balls are designed for float valves, water tanks, and industrial liquid... | |
| Precision Design for Automatic Liquid Level Control | Seller: Yongjia County Yaokang Technology Co., Ltd. | Our stainless steel float balls are designed for liquid level control applications in valves, tan... | |
| "China manufacturer power supply VM-5H3 for power generation | Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "China manufacturer power supply VM-5H3 for power generation Is to use the generator sets of prof... | |
| Reliable Components for Water and Industrial Systems | Seller: Yongjia County Yaokang Technology Co., Ltd. | The Stainless Steel Float Ball is designed for automatic liquid level control and fluid managem... | |
| Double Convex Lenses | Seller: Shandong Yanggu Constant Crystal Optics, Inc | Double Convex Lensesare used in image relay applications, or for imaging objects at close conjuga... |













