BMS for ESS
The energy storage battery management system consists of battery pack management unit (BMU module), battery cluster management unit (RCU module), system management unit (SCU module) and system display management unit (MM10 module). This lithium bms battery management systemsupports a maximum of 1500V energy storage system.
Topology of BMS ESSFeatures of BMS for ESS
3+1 level structure
Online program upgrade
Support bidirectional IO ports to achieve automatic address coding
Multi-ports environment supervision devices data access
Function of BMS for ESS
Battery information management
Cluster status monitoring
Cluster status analysis
Safety control and protection
Energy control management
Battery maintenance management
Communication port and protocol
Specification of BMSof Batteryfor ESS
BMU Module
Category |
Item |
Specification |
||||
Working environment |
Temperature |
Operating temperature:-20~+65°C |
Storage temperature:-40~+125°C |
|||
Working power |
Voltage/Power consumption |
Rated voltage:9~32Vdc(reverse connection protection) |
Rated power consumption: 120mW (without load) |
|||
Communication |
CAN |
Support 1-channel non-isolated CAN |
Communication rate: 250kbs |
|||
Collection |
Cell voltage collection |
Collection range: 0~5V |
Collection resolution: 1mV |
Collection accuracy: |
Collection rate:100ms |
Electrical isolation: |
+10≤t≤+45 °C, the accuracy ≤5mV; |
4149Vdc/2934Vac (8mm) |
|||||
-40~≤t≤125°C, the accuracy ≤8mV |
||||||
Cell temperature collection |
Collection range: -40~+125°C |
Collection resolution: |
Collection accuracy: |
Collection rate:200ms |
||
-20≤t≤+65°C, the accuracy≤1°C; |
||||||
-40≤t≤+125°C, the accuracy≤2°C |
||||||
Cell equalization |
Cell equalization control |
Support 24-channel cell passive equalization |
Equalization resistance: 33Ω |
Equalization temperature rise:≤45°C |
RCU Module
Category |
Item |
Specification |
|||||
Working environment |
Temperature |
Operating temperature:-20~+65°C |
Storage temperature:-40~+125°C |
||||
Communication |
CAN/RS485 |
Support 1 isolated CAN and 1 non-isolated CAN |
2 isolated RS485 |
||||
Collection |
Total voltage |
Collection range: 0~1500V |
Collection resolution: 0.1V |
Collection accuracy: |
Collection rate: |
Electrical isolation: |
|
collection |
Total voltage<1000V (≤±1%FS) |
100ms |
4149Vdc/2934Vac (8mm) |
||||
Total voltage ≥1000V (≤±0.5%FS) |
|||||||
Total current |
Collection range: ±1200A |
Collection resolution: 0.1A |
Module circuit collection accuracy: ±1200A, accuracy ±1%FS |
Collection rate: |
|||
collection |
200ms |
||||||
Insulation collection |
Collection range: 0~10MΩ |
Collection accuracy: accuracy≤3% (500V~1500V, ≥600KΩ) |
Collection rate: 60s |
||||
(adjust according to the Y capacitance value of the PCS device) |
|||||||
Temperature collection |
Collection range: -40~+125°C |
Collection resolution: 1°C |
Collection accuracy: |
Collection rate: |
|||
-20~+65°C, accuracy≤1°C; |
200ms |
||||||
-40~+125°C, accuracy≤2°C |
|||||||
Monitoring capability |
1 RCU module can max. manage 32 BMU modules |
SCU Module
Category |
Item |
Specification |
|
Working environment |
Temperature |
Operating temperature: |
Storage temperature: |
-20~+65°C |
-40~+125°C |
||
Communication |
LAN communication |
Communication rate: 10M/100M |
Electrical isolation: 3000Vdc |
CAN communication |
Communication rate: 250kbs |
Electrical isolation: 2500Vdc |
|
RS485 communication |
Communication rate: 9600kbs |
Electrical isolation: 2500Vdc |
|
RS232 communication |
Communication rate: 9600kbs |
Electrical isolation: 2500Vdc |
|
Storage |
Data record |
On-board eMMC |
External expansion TF |
storage space: 8G |
card storage space: 0~128G |
||
Insulation |
Communication |
LAN:3000Vdc |
CAN/RS485/RS232:2500Vdc |
Monitoring capability |
1 SCU module can max. manage 30 RCU modules |
MM10 Module
Category |
Item |
Specification |
|
Working environment |
Temperature |
Operating temperature: |
Storage temperature: |
-10~+60°C |
-20~+70°C |
||
Working power |
Voltage/Power consumption |
Rated voltage:9~30Vdc |
Rated power |
consumption:10W |
|||
Communication |
LAN |
1 isolated LAN |
Communication rate: |
10M/100M |
|||
Basic parameter |
micro USB port |
Support 1-channel micro USB for system |
|
programming and ADB debugging |
|||
Screen |
Capacitive touch screen |
||
Storage |
Data record |
eMMC storage space:8G |
TF card storage space: |
0~128G |
|||
Hardware parameter |
CPU processor |
RK3288/4 core frequency 1.6GHz |
|
Run system |
Android 7.1 |
||
GPU |
ARM Mail-T764 |
在线联系供应商
Other supplier products
Battery Management System Used In Public Utilities | Battery Management System is essential to the utility industry. Huasu BMS provides long-term backup power security support to the public utilities.... | |
H3G-TSX Battery Management System | H3G-TSX bms lead acid batterymonitoring system is providing not only real-time monitoring of normal battery parameters but intelligent alarms analy... | |
LiFePO4 Battery | Lifepo4 storage batteryis widely used in the fields of electric vehicles, digital products, electric equipment, and so on. This type of energy stor... | |
Battery Management System Applications | Battery Management System Application Huasu Battery Management System has been widely used in key backup power supplies such as data centers, comm... | |
H3G-THWL Battery Management System | H3G-TH WL active balancing battery management systemadopts a new generation of ZigBee wireless communication technology, which reduces on-site wiri... |
Same products
Electric Motorcycle High Energy Lithium Battery | 卖方: Taizhou CGONEN New Energy Co., Ltd. | Our 60V26Ah/ 60V29Ah/ 60V32Ah NMC high-speed electric motorcycle high-energy lithium batteries re... | |
MECHANIC Max28 Battery Activation Board for iPhone 8-16 Pro Max & Android | 卖方: Phonefix | Mechanic Max28 battery activation detection board activates iPhone 6-16 Pro Max, VIVO OPPO Samsun... | |
PHONEFIX W23 Universal Battery Fixture For Spot Welding Machine | 卖方: Phonefix | PHONEFIX Professional Edition Battery Spot Welder Anti-static Welding Fixture for Mobile Phone Ba... | |
OSS T5 Lightning Type-C Micro Data Cable Detection Board | 卖方: Phonefix | OSS T5 Data Cable Detection Board quickly detect abnormal data cable issues, it can be connected ... | |
Portable Battery Power Station | 卖方: DongGuan Cham Battery Technology Co.,LTD | CHAM is a company that provides portable power stations, designed to offer a reliable power sourc... |