2021 New design automatic circuit recloser/ Auto recloser
TD-CHZ16 protector integrates intelligent control functions such as over-current and short-circuit protection, under-voltage/over-voltage protection, leakage protection, remote communication management/fault memory, detection before closing, and automatic reclosing device. The new generation TD-CHZ16 protector has the characteristics of intelligence, safety, wide application range, stability and long service life.
Auto Recloser Function
When the current of the auto-reclosing leakage protector is greater than 3 times the rated current, the auto-reclosing leakage protector will be disconnected within 0.1 second to ensure the safety of the equipment.
The leakage current of TD-CHZ16 factory setting is 30ma. When a 15~30mA leakage occurs on the wire, the automatic reclosing will be disconnected within 0.1 second.
TD-CHZ16 type protector realizes the rated current 6A-10A-16A adjustable, and the maximum support is 16A. When the current is greater than 1.15 times the rated current, the auto-reclosing will monitor the duration and magnitude of this current; if the duration exceeds 3 seconds or is greater than 3 times the rated current, The automatic reclosing leakage protection switch is disconnected for protection
When the supply voltage is higher than 275V±5V, the auto-reclosing will be disconnected. After the voltage drops back to normal, the auto-reclosing will automatically close and energize.
When the power supply voltage is lower than 150V±5V, the automatic reclosing will be disconnected. After the voltage rises to normal, the automatic reclosing will automatically close, The power-on operation status is normal.
The automatic reclosing detects the line voltage before closing. When the power supply voltage is abnormal under-voltage or over-voltage, it will block the closing
and Alarm; if the fault is not eliminated, the switch cannot be closed and energized. When the fault is removed, the switch will automatically close and energize.
When there is an instantaneous leakage or an instantaneous impact on the line, such as lightning, socket flashover, etc., and there may be danger, the automatic reclosing leakage protector will be disconnected immediately;
After the fault, if the line is safe, the auto-reclosing will automatically reclose and energize. The number of closing times is unlimited
Technical Parameter of Adjusted Automatic Circuit Recloser
Model |
TD-CHZ |
Feature The working current is 16A, the leakage current can be adjusted, built-in lightning protection module, the discharge current can reach 10KA |
|
Working voltage Un |
220V 50HZ |
385V |
|
Rated load current RLA |
16A(6A/10A/16A) |
Overcurrent action current |
|
The inert current of leakage |
15 mA |
Leakage action current (adjustable) |
30 mA |
Overvoltage operating voltage (factory adjustable) |
275V±5V |
Undervoltage operating voltage (factory adjustable) |
150V±5V |
Overcurrent disconnect action time |
≤2s |
Short circuit disconnection operation time |
≤0.1 s |
Leakage disconnect action time |
≤0.1 s |
Overvoltage, undervoltage |
≤0.5s |
Disconnect time |
|
Load impedance that allows reset |
10 Ω |
Lightning resistance |
10KA () |
Voltage detection before closing |
Yes |
Reclosing time(factory adjustable) |
60s/120s/300s/1800s/3600s-10 次 |
Specification and installation |
95mm*93mm*65mm, DIN-rail |
If you want to know more details of auto recloser working principle, please visit our website.
Techwin Inc. is one of the most professional surge protector manufacturers in China. With matured experience in surge protection technology, Techwin surge protection devices manufacturer, whose spd surge arresters obtained 28 technology patents and multiple certifications such as CE, ROHS, TUV, UL, CQC, ISO9001, ISO14001, ISO45001 and so on. Telecom, electric power, CCTV, railway, intelligent transportation, solar wind power, petrochemical engineering and other industries all need spd protection devices, our lightning surge protectorfactory can provide surge protector arresters in line with the latest international and domestic standards.
在线联系供应商
Other supplier products
SCB ( Surge Protector Circuit Breaker )-SSD ( SPD Specific Disconnector) | In low voltage power systems, a power surge circuit breaker(SCB)-SSD ( SPD Specific Disconnecotor) is an external disconnector used in series with ... | |
DC Power SPD | DC power supply SPD, also called DC lightning arrestor or DC surge suppressor, is designed for the protection of DC power circuit from the damage o... | |
SPD for Network / Data Line Surge Protector | Data line protector series are mainly used in TCP/IP communication networks to protect electrical and electronic equipment's signal line from the i... | |
SPD for Network / Data Line Surge Protector | Data line surge protectorseries are mainly used in TCP/IP communication networks to protect electrical and electronic equipment's signal line from ... | |
Signal SPD | Signal surge protective device(SPD) is actually a signal lightning arrester, which is installed in series in the signal transmission line, usually ... |
Same products
Fire Hose Connector | 卖方: Zhejiang Fengruichen Fire Fighting Equipment Co., Ltd. | Fire Hose Connector is suitable for snowmaking in ski resorts. It uses high-quality TPU and polye... | |
Labor Protection Products | 卖方: O&K GROUP LIMITED | Okwishing supplies all kinds of Labor Protection Products Okwishing () is a cross-border e-commer... | |
Combo Flex Rubber Covered Fire Hose | 卖方: Zhejiang Fengruichen Fire Fighting Equipment Co., Ltd. | Combo Flex is a multi-purpose PVC covered hose, suitable for short-distance industrial fluid tran... | |
MECHANIC iScout 热成像摄像机主板故障分析仪 | 卖方: PHONEFIX technology Co.,Ltd | 描述Mechanic iScout 红外热成像摄像机电子电路板故障分析仪,用于手机/iPhone/iPad/平板电脑 PCB 分析、诊断和故障排除。Mechanic iScout 热像仪具有 2... | |
智能应用程序控制 WiFi 烟雾探测器报警器适用于家庭安全火灾报警 | 卖方: 深圳市巡鹰安防科技有限公司 | 无线光电烟雾火灾探测报警器(简称“烟雾探测器”)是一种通过感应烟雾来探测火灾的设备。当产生烟雾并达到一定浓度时,设备会发出声光报警信号,同时向主机发送无线信号,提示您现场... |