Automotive wire cyclic bending testing machine

Standard

This testing machine aligns with global automotive industry standards for wire harness reliability, includingISO 6722(Road vehicles – Cables for conductor sets) andSAE J1128(Low-voltage battery cable specifications). By simulating repetitive bending stresses, it evaluates wire fatigue resistance under dynamic conditions, ensuring compliance with OEM specifications for in-vehicle wiring durability.

Product Advantages

  • Versatile Angle Adjustment: Swings up to 180° bi-directionally or any user-defined angle, accommodating sharp-bend (e.g., R3.75) and gradual-curve testing scenarios.
  • Triple-Station Efficiency: Three independent test channels enable parallel testing of different wire specifications, tripling throughput compared to single-station machines.
  • Precision Fatigue Analysis: ±1 cycle/min speed control and 6-digit counter ensure accurate life-cycle prediction, critical for validating warranty periods.
  • Adaptive Fixture System: Interchangeable R-angle fixtures (R3.75. R7.2. R9.6. etc.) cater to wires from thin gauge (0.5mm²) to heavy-duty cables, eliminating costly retooling.
  • Safety & Data Integrity: Automatic stop-on-break function prevents post-failure damage, while memory retention resumes testing after power interruptions.

Product Features

  1. Dynamic Swing Mechanism: 180° rotation with adjustable angles (1° increments) via digital control panel.
  2. Variable Speed Control: 10–60 cycles/minute operation with real-time speed display and over-speed protection.
  3. Modular Test Stations: Three channels with individual start/pause controls and LED status indicators.
  4. Load Configuration: Four precision weights (2.5N, 3.75N, 5N, 7.5N) for simulating varying vibration/flexure stresses.
  5. Diagnostic Capabilities: Built-in 24V test voltage output for continuity monitoring during bending cycles.
  6. Robust Construction: 50KG steel frame with vibration-damping feet ensures stable operation at maximum load.

Technical Parameters

ParameterSpecification
Swing Angle Range 0°–180° (CW/CCW), adjustable in 1° increments
Operating Speed 10–60 cycles/min (±1 cycle tolerance)
Cycle Counter 1–999,999 counts (presettable with pause/resume)
Test Stations 3 independent channels with quick-release fixtures
Applied Loads 2.5N, 3.75N, 5N, 7.5N (interchangeable weights)
Fixture R-Angle Options R3.75, R7.2, R9.6 (customizable per AWG/mm²)
Test Voltage 24V DC (built-in supply)
Power Input AC 220V ±10%, 50/60Hz (switchable to DC 24V/5A)
Machine Dimensions (W×D×H) 600 × 450 × 750 mm
Net Weight 50 kg

在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Washing Fastness testing machine
Washing Fastness testing machine G228B washing fastness tester is used for washing, dry-clean color fastness testing. Electric touch switch, LCD menu display, without mechanical co...
Sock Stretch Tester
Sock Stretch Tester The Electronic Multifunction Socks stretcheris mainly used to determine the straight extension and transverse extension of stockings, swimwear, pan...
Xenon Test Chamber/weather ometer
Xenon Test Chamber/weather ometer Introduction Weather-Ometer and Fade-Ometer tester adopts water-cooled xenon lamp. This instrument using argon arc lamp simulation control ideal n...
Universal Wear Tester
Universal Wear Tester Standards ASTM Standards: D3514, D3885, D3886 (textile, coating, and plastic wear resistance) AATCC Standards: 119, 120 (fabric abrasion and pi...
100-V2 steam generator tester
100-V2 steam generator tester Meet the standard: The 100-V2 steam generator meets the requirements of Ford FLTM BI 107-05. GMW15919 and FCA LP-463PB-64-01 thermal shock test sp...
供应产品

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution 卖方: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors 卖方: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber 卖方: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester 卖方: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors 卖方: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...