.

Automotive wire cyclic bending testing machine

Standard

This testing machine aligns with global automotive industry standards for wire harness reliability, includingISO 6722(Road vehicles – Cables for conductor sets) andSAE J1128(Low-voltage battery cable specifications). By simulating repetitive bending stresses, it evaluates wire fatigue resistance under dynamic conditions, ensuring compliance with OEM specifications for in-vehicle wiring durability.

Product Advantages

  • Versatile Angle Adjustment: Swings up to 180° bi-directionally or any user-defined angle, accommodating sharp-bend (e.g., R3.75) and gradual-curve testing scenarios.
  • Triple-Station Efficiency: Three independent test channels enable parallel testing of different wire specifications, tripling throughput compared to single-station machines.
  • Precision Fatigue Analysis: ±1 cycle/min speed control and 6-digit counter ensure accurate life-cycle prediction, critical for validating warranty periods.
  • Adaptive Fixture System: Interchangeable R-angle fixtures (R3.75. R7.2. R9.6. etc.) cater to wires from thin gauge (0.5mm²) to heavy-duty cables, eliminating costly retooling.
  • Safety & Data Integrity: Automatic stop-on-break function prevents post-failure damage, while memory retention resumes testing after power interruptions.

Product Features

  1. Dynamic Swing Mechanism: 180° rotation with adjustable angles (1° increments) via digital control panel.
  2. Variable Speed Control: 10–60 cycles/minute operation with real-time speed display and over-speed protection.
  3. Modular Test Stations: Three channels with individual start/pause controls and LED status indicators.
  4. Load Configuration: Four precision weights (2.5N, 3.75N, 5N, 7.5N) for simulating varying vibration/flexure stresses.
  5. Diagnostic Capabilities: Built-in 24V test voltage output for continuity monitoring during bending cycles.
  6. Robust Construction: 50KG steel frame with vibration-damping feet ensures stable operation at maximum load.

Technical Parameters

ParameterSpecification
Swing Angle Range 0°–180° (CW/CCW), adjustable in 1° increments
Operating Speed 10–60 cycles/min (±1 cycle tolerance)
Cycle Counter 1–999,999 counts (presettable with pause/resume)
Test Stations 3 independent channels with quick-release fixtures
Applied Loads 2.5N, 3.75N, 5N, 7.5N (interchangeable weights)
Fixture R-Angle Options R3.75, R7.2, R9.6 (customizable per AWG/mm²)
Test Voltage 24V DC (built-in supply)
Power Input AC 220V ±10%, 50/60Hz (switchable to DC 24V/5A)
Machine Dimensions (W×D×H) 600 × 450 × 750 mm
Net Weight 50 kg

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Geosynthetic Clogging Tester
Geosynthetic Clogging Tester Scope of application: The method of gradient ratio is used to measure the permeability coefficient and permeability ratio of soil and geotextile s...
3D Geophysical Instrument
3D Geophysical Instrument Product Introduction: The 3D Formation Tester measures layers of paper, fiberglass, cardboard, paper towels and towels, and many other sheetlike m...
Wyzenbeek or Oscillatory Abrasion Tester-QINSUN
Wyzenbeek or Oscillatory Abrasion Tester-QINSUN Product introduction: Wyzenbeek wear resistance tester, also known as Oscillatory wear resistance tester, is used to test the wear resistance of f...
Initial drying resistance test machine
Initial drying resistance test machine Standards GB9779-2015 GB14907-2002 GB/T9271-2008 JG/T24-2000 Technical parameters 1. axial fan, can be stepless speed regulation 2.Test th...
Electronic Crockmeter
Electronic Crockmeter G238BB Electronic Crockmeteris used for testing the color fastness of fabric and leather by dry/wet rubbing.The tester makes the sample repeatedly ...
All supplier products

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Seller: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Seller: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Seller: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Seller: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Seller: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...