Flooring Radiant Panel Test Apparatus
Standards
ISO 9239-1: Flooring fire reaction test - Part 1: Combustion performance of flooring materials tested by radiantheat
ASTM E 648: Critical Radiant Flux of Floor standard test - covering system uses radiant heatenergy
ASTM E 970: Using a Radiant Heat Energy Source, test insulationfloorinsulationinsulationstandardtestforCriticalRadiantFlux
using a radiant heat energy.
NFPA 253: Standard Test Method for using radiant heat energy, test plates overlay system Critical RadiantFlux
Main Features
1. All structural components are made of stainless steel, nice appearance, corrosion resistance;
2. The radiation source is a porous ceramic heat radiating plate 300mmX450mm, tilted 30 °;
3. Imported calorimeter from US Medtherm company, range 50KW /m;
4. Igniters diameter of 0.7mm from the bottom of the center line of each 60-degree position accordingtostandardrequest.
5. The standard plate is made of thick 20 ± 1mm, density 850 ± 100kg / m³ without coating made of calcium silicate board; size 1050X250mm
6. Small stainless steel auxiliary ignition burner ignited sample.
7. Imported flow control meter from Japan, precise control of the flow of propane
8. Equipped with air blower providing air, mixed gas through the venturi mixing test gas,
9. The specimen holder is made of stainless steel and an overall dimension of 1140mm x 320 mm.
Optical system
1. The optical system comprising a light source color temperature is 2900 ± 100 K incandescent,lightreceivingsilicon photodiode with an optical path test shutter, 0% and 100%, to facilitate the use of calibration;
2. Imported light battery module measuring light attenuation. The system automatically calculates and generates a light transmittance curve translucent; printable Scribble
3. One button automatic and five level calibration system by computer.
Thermal radiation system
1. Heat radiation pyrometer accuracy of ± 0.5 ºC, away from the radiation board about 1.4m;
2. Radiation pyrometer sensitivity constant in the wavelength range 1um ~ 9um;
3. High-performance K-type thermocouples diameter 1mm, having insulation and ungrounded hot junction; in the lower box roof 25mm, the inner wall of the rear housing flue 100mm;
4. Radiation pyrometer to detect a diameter in the range of 250mm, blackbody radiation temperature within a temperature range of 480 ºC ~ 1200 ºC ;
5. USA imported heat flux sensors with NIST traceable calibrator with a minimum resolution of 0.01 mV.
Control System
1. Window + Labview system to realize automatictestsysterm
2. Equipped with audible alarm and alarm display functions accidents.
3. The control box USB / RS232 serial port,externaldesktop/notebookcomputeroperation control, free to print the test report.
4. Automatic calibration system.
Specification
Pover:AC220V±10%, 50Hz;5KW;
Size:Test stand(Length1.4× width1.0× High2.2)m;
Control box: 600(W)×750(D)×1600(H)mm
Weigth:350Kg.
在线联系供应商
Other supplier products
| Respirator Fit meter | PortaCount Respirator Fit Tester: Qinsun assesses the overall integrity of masks by performing an aerosol leak test utilizing the PortaCount Respi... | |
| White Body Rigidity Test Stand | The whole system of loading and testing process can achieve automation, intelligent to meet the different models of body detection. The test system... | |
| Water injection counterweight dummy | Product Introduction This counterweight dummy can be filled with water, the torso and the bottom are separated, independently filled with wat... | |
| Small Component Safety Tester (for Small Parts Tester) | Test Procedure: Usage Methods and Interpretations Applicable standards: ASTM F963 EN 71-1 16 CFR Part 1501 ISO 8124-1 Product Advantages: Eff... | |
| Geosynthetic Clogging Tester | Scope of application: The method of gradient ratio is used to measure the permeability coefficient and permeability ratio of soil and geotextile s... |
Same products
| Composite Flame Retardant For Adhesive XS-FR- 308/XS-FR-708 | 卖方: Zhejiang Xusen Flame Retardants Incorporated Company | XS-FR-308/XS-FR-708 are nitrogen phosphorus composite, low smoke intumescentflame retardants, whi... | |
| Adjustable flame length tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 5169.5: Electrical & E... | |
| Fabric Flame Retardant Tester | 卖方: 上海千实精密仪器 | Product details A method is used to determine the damaged area and the length of the damage when... | |
| Burning Manikin System | 卖方: 上海千实精密仪器 | Product details The burning manikin system is used to test the overall thermal protection perfor... | |
| Steel Structure Fireproof Coatings | 卖方: 上海千实精密仪器 | Product Introduction: Heat insulation efficiency and fire resistance test furnace of steel struc... |