Coating scratch test equipment for durability testing
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
(1) GB 4706.1-2005 Safety of household and similar electrical appliances – Part 1: General requirements, Clause 21.2
(2) GB 4943.1-2011 Information technology equipment – Safety – Part 1: General requirements, Clause 2.10.8.4
(3) IEC 60335-1:2004 Household and similar electrical appliances – Safety – Part 1: General requirements, Clause 21.2
(4) IEC 60950-1:2005 Information technology equipment – Safety – Part 1: General requirements, Clause 2.10.8.4
Parameters
| Parameter | Specification |
|---|---|
| Power supply | 220 V AC, 50 Hz |
| Test station | Single station |
| Control system | PLC control, 7-inch color touch screen, stepper motor drive |
| Stylus tip radius | R0.25 ± 0.02 mm |
| Stylus apex angle | 40° |
| Scratch speed | 20 ± 5 mm/s (presettable) |
| Scratch force | 10 ± 0.5 N |
| Scratch spacing | 0–50 mm (presettable) |
| Scratch angle | 80–85° (fixture fixed) |
| Specimen tray | Rotatable by 90°, multiple mounting holes |
Features
Standard-compliant stylus geometry with polished rounded tip.
Precise motion control using stepper motors and programmable parameters.
Stable load application to maintain constant 10 N test force.
90° rotatable specimen tray suitable for different sample sizes and orientations.
Flexible starting-point selection (center-based or arbitrary positioning).
Automatic cycle operation with return-to-origin function after completion.
Accessories
(1) Scratch stylus × 1
(2) Hex key set × 1
(3) Specimen pressure plates × 4
Test Procedures
1. Specimen installation
Center the specimen on the test platform.
For large samples, secure using clamping plates.
For thin samples (< 2 mm), place the flat side of the pressure plate directly on the specimen.
2. Parameter setting
Start point selection (choose one method):
Center mode: Scratches are symmetrical about the rotary center.
Arbitrary start point: Manually move the stylus to the desired position and confirm as the start point.
Vertical position setting:
Lower the stylus manually until it is lifted by the specimen surface.
Record this position and input it as the “downward position” in the control interface.
Motion parameters:
Preset vertical, horizontal, and forward speeds (horizontal speed: 20 ± 5 mm/s).
Set scratch length ensuring that after 90° rotation the scratches remain within the specimen and do not intersect.
Set scratch spacing (minimum 5 mm between lines and 5 mm from specimen edge).
Set number of scratches and select 90° rotation if required.
3. Test operation sequence
Press Return to Origin, then Start.
The stylus moves: Origin → selected start point → descends to test position → performs scratch → lifts → returns to start point → advances spacing → repeats cycle → stops automatically and returns to origin.
Send product request
Other supplier products
| Contact heating and cooling tester STD-F7 | Whats/App: +86 156 1874 6768 Web: standard-groups.com The sensation of coldness or warmth when skin touches a fabric is referred to as the "coldn... | |
| Vertical flame test chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction The Vertical Flammability Chamber, designed for American Standards, measures ... | |
| Surface Scratch Test Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary test objects Accessible solid insulating parts of household appliance... | |
| Fully Automatic Scratch Hardness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary applications: Evaluation of scratch resistance on insulated single-la... | |
| Material wear test equipment supplier OEM factory direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Protective Clothing Impact Abrasion Tester is designed to evaluate the im... |