LM-79 Moving Detector Type C Goniophotometer
LSG-6000 Moving DetectorGoniophotometer(Mirror Type C) was manufactured by LISUN completely meetsLM-79-19,IES LM-80-08,COMMISSION DELEGATED REGULATION (EU) 2019/2015,CIE-121, CIE S025,SASO 2902, IS16106 andEN13032-1clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m.
What is the use of goniophotometer?
LSG-6000 gonio photometermanufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Measurement:
Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.
Features:
• The near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.
• The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares.
• The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop.
• The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards.
• Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately.
Specifications:
• The luminaire under test rotates around the mirror with an angle of (γ) vertical axis ±180° (or 0-360°) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180° (or 0-360° ).
• The accuracy of angle: 0.05°, Resolution of angle: 0.001°
• Accuracy of Goniophotometrydetector: Constant temperaturephoto detectorDIN5032-6/CIE pub1. No. 69 Class L
• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux.
• Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11
• LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-6000CCD)". LSG-6000CCD Goniospectroradiometer =LSG-6000 Goniophotometer System+LPCE-2 Integrating sphere Spectroradiometer System. Please click to download theLSG-6000CCD Brochure
• The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files
Send product request
Other supplier products
High Voltage Lightning Surge Generator | Basic Info. Model NO. SG-61000-5 After-sales Service Perfect Warranty 24months Trademark LISUN Origin China ... | |
Electrodynamic Vibration Generator Test Table | Product Description LVD-100KG/LVD-100KG-6DElectrodynamic Vibration Generator Test Table is according toIEC 60068, IEC68-2-6,JJG189-97,GB/T1330... | |
Lamp Start, Run-up time and Flicker Test | Product Description LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric pr... | |
Automatic Electrical Safety Tester | Product Description The LS9955/LS9956Automatic Safety Test System(electrical safety analyzer) combined the following function in one set: With... | |
LM-79 Moving Detector Type C Goniophotometer | LSG-6000 Moving DetectorGoniophotometer(Mirror Type C) was manufactured by LISUN completely meetsLM-79-19,IES LM-80-08,COMMISSION DELEGATED REGULAT... |
Same products
MECHANIC MEC 4K 2K HD Electronic Eyepiece Camera for Stereo Microscope | Seller: SHENZHEN PHONEFIX TECHNOLOGY CO.,LTD (CHINA PHONEFIX) | Description Mechanic MEC 2K/2K PRO/4K HD Electronic Eyepiece Camera can convert a Binocu... | |
Fluke 15B+ 17B+ 18B+ Digital Multimeter Voltage Frequency Tester | Seller: PHONEFIX technology Co.,Ltd | iFixes 10CC半透明/全透明/乳白/浅黄色无铅焊膏适用于手机主板CPU BGA维修。iFixes Solder Flux注射器注射焊膏焊膏手机修整焊接耗材系列,适用于电路板纳米芯片、手机... | |
HTT-02 Hot Tack Tester | Seller: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | Seller: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | Seller: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... |