LM-79 Moving Detector Type C Goniophotometer

LSG-6000 Moving DetectorGoniophotometer(Mirror Type C) was manufactured by LISUN completely meetsLM-79-19,IES LM-80-08,COMMISSION DELEGATED REGULATION (EU) 2019/2015,CIE-121, CIE S025,SASO 2902, IS16106 andEN13032-1clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m.

What is the use of goniophotometer?

LSG-6000 gonio photometermanufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.

Measurement:
Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.

Features:
• The near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.
• The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares.
• The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop.
• The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards.
• Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately.

Specifications:
• The luminaire under test rotates around the mirror with an angle of (γ) vertical axis ±180° (or 0-360°) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180° (or 0-360° ).
• The accuracy of angle: 0.05°, Resolution of angle: 0.001°
• Accuracy of Goniophotometrydetector: Constant temperaturephoto detectorDIN5032-6/CIE pub1. No. 69 Class L
• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux.
• Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11
• LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-6000CCD)". LSG-6000CCD Goniospectroradiometer =LSG-6000 Goniophotometer System+LPCE-2 Integrating sphere Spectroradiometer System. Please click to download theLSG-6000CCD Brochure
• The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files


Send product request

To: LISUN ELECTRONICS (SHANGHAI) CO.,LTD
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

LED Power Driver Tester
LED Power Driver Tester Product Description LS2090 LED Power Driver Test Instrument is the comprehensive test instrument for LED driver power which is according toGB/...
Salt Spray Test Chamber
Salt Spray Test Chamber Product Description Salt Spray Test Chamber | Salt Fog Test | ASTM B117 Salt Spray ChamberSalt Spray Test Chamberis applicable to the salt spr...
Lamp Start, Run-up time and Flicker Test
Lamp Start, Run-up time and Flicker Test Product Description LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric pr...
High and Low Temperature Humidity Chamber
High and Low Temperature Humidity Chamber Product Description Temperature Humidity Chamber | Thermal Chamber | Climate Chamber is according toIEC60068-2-1(GB/T2423.1) and IEC60068-2-2 ...
High Precision Spectroradiometer Integrating Sphere System
High Precision Spectroradiometer Integrating Sphere System Basic Info. Model NO. LPCE-2 After-sales Service Perfect Warranty 24months Trademark LISUN Origin China ...
All supplier products

Same products

KL‑016A Benchtop High‑precision pH Meter
KL‑016A Benchtop High‑precision pH Meter Seller: Kelilong Electron Co.Ltd Product Description: Large‑screen display with high resolution and precision for con...
Large Naïve VHH Library
Large Naïve VHH Library Seller: AlpVHHs Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o...
pH-2398  pH/EC/ORP/Temperature  multi-parameter Water Quality Tester
pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester Seller: Kelilong Electron Co.,Ltd Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent...
ORP-2026S  Waterproof Soil ORP and Temperature Meter
ORP-2026S Waterproof Soil ORP and Temperature Meter Seller: Kelilong Electron Co.,Ltd 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
TDS-2616  Waterproof EC/TDS/Temperature Meter
TDS-2616 Waterproof EC/TDS/Temperature Meter Seller: Kelilong Electron Co.,Ltd Range EC ~19.9mS TDS Temp 0~50℃ R...