SK-DTL Concrete Resist Chloride Ion penetration tester
Detection method: electricity
Executive Standard
Standard for test methods of long-term performance and durability of ordinary concrete(GB/T50082-2009)
The Provisional Technical conditions of Passenger special line high-performance concrete
Corrosion prevention technical specification for concrete structure of marine harbour engineering JTJ275-2000
Apparatus to determine chloride coulomb electric flus of concrete(JG/T261-2009)
Manufacturer:
Application:
Concrete reinforcement corrosion is the primary factor affecting the durability of concrete.According to statistics, the durability damage of reinforced concrete caused by corrosion accounted for more than 40% of all injuries, while the chloride ion erosion is a major incentive for reinforcement corrosion. DTL concrete chloride ion electric flux detector can be an important indicator for the durability of concrete - concrete to resist chloride ion penetration properties (density) measurements, test indicator is the six-hour power flux (Coulomb)for the concrete specimens, quickly to evaluate the concrete resistance to the chloride ion penetration ability
Product features:
1. Embedded computer control, power outages and power-down data storage, advanced technology, well-made, reliable performance, high accuracy
2. LCD display, with real-time display/print and analysis function, can be separated from Pc to use directly, to facilitate the outdoor field detection.
3. Standard RS232 serial communications with fully automatic PC connection software can output the flux test report to generate curve, and then print for analysis and archiving
4. Automatic short circuit protection to avoid equipment damage
5. Imported material fixture, high accuracy, easy and smart to use
6. Can simultaneously test two groups (6), three (9), four (12) or five (16) concrete block one time
7. With the latest smart-in-one vacuum saturated machine
Technical parameters
• Evaluation capacity: C30 ~ C50 portland cement concrete
• Working voltage: ~220VAC 60VDC
•Test channels: 6 channels, 9 channels, 12 channels, 16 channels optional
•Work environment: 0 centigrade ~ 50centigrade Humidity =< 75%
•Measurement error: <1%
Equipment specification:
Host dimension: 385*345*145(mm)
Host weight: 5kg
Host outside dimension: 530*200*420
Vacuum saturated machine weight: 32kg
Vacuum saturated machine dimension: 750*680*400(mm)
Accessories weight: 9kg
Accessories dimension: 440*350*210(mm)
Total weight: 46kg
System Configuration
Concrete Resist Chloride Ion penetration tester
specimen fixture
NJ-BSJ concrete vacuum saturated machine
Test steps:
1. Cut the concrete Standard sample into 50mm thickness test block
2. The sample will be saturated with water in the intelligent concrete vacuum saturated machine
3. After the vacuum saturated, the specimens will be installed on the fixture
4.Inject the concrete solution( NaCl (negative), NaOH (positive) )into the specimen fixed poles
5.Connect the concrete Flux detector power and the positive and negative of specimen fixture
6.Connect the test host, test software control, the test results will be obtained after 6 hours
7.Data is automatically saved and can be printed.
Send product request
Other supplier products
| SK225-V digital voice test hammer | Brief introduction: Test hammer SK225-V submitted to GB /T9138-1988, JJG817-93 and JGJ/T23-2001 standards. The instrument is useful for quality In... | |
| SKSJ-10 tapestry brick adhesive strength tester | Executive Standard JGJ110-2008 Testing standard for adhesive strength of tapestry brick of construction engineering JGJ126-2000 Specification for c... | |
| SK-40/60 Multifunction strength tester | Executive standard (CECS69:94) Technical specification for inspection of concrete strength by pull-out post-insert method (JGJ 110-2008) Testing st... | |
| SK-RCM Rapid Concrete chloride migration tester | Detection method: Electromigration method (RCM) Executive Standard: NT BUILD 492(Chloride Migration Coefficient from Non – Steady - State Mig... | |
| SK-DTL Concrete Resist Chloride Ion penetration tester | Detection method: electricity Executive Standard Standard for test methods of long-term performance and durability of ordinary concrete(GB/T50082-2... |
Same products
| Optical Brightener OB-1 (OBA 393) | Seller: Jinan Ogilvy Chemical Co., Ltd | Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo... | |
| PH-A63 Waterproof PH/EC/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c... | |
| PH-A6 Waterproof pH and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ... | |
| PH-A8 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ... | |
| TH021WIFI Internet of Things TEMP&HUMIDITY Controller | Seller: Kelilong Electron Co.,Ltd | Product description: The electronic thermostat can be used for a variety oftemperature control... |