Wrinkle Recovery Tester
The main principle of the wrinkle recovery tester is to apply a predetermined pressure to the specimen under standard atmospheric conditions and to maintain the specified time. The overall structure of the instrument and the precise spiral column ensure that the loaded specimens produce a uniform deformation. After removing the sample from the instrument, re-adjust the sample under standard atmospheric conditions and allow it to recover for a certain period of time, and then compare the sample with the reference sample to assess the appearance of the sample.
The instrument consists of a base with a bracket, the base of the fixed steel plate and the top of the movable steel plate to match ,the activities of the flange with the locking pin. Equipped with four standard weights, respectively, 2000g, 1000g, 500kg, 200kg.
Application
The instrument consists of a base with a bracket, the base of the fixed steel plate and the top of the movable steel plate to match ,the activities of the flange with the locking pin. Equipped with four standard weights, respectively, 2000g, 1000g, 500kg, 200kg.
Application
The wrinkle recovery test instrument detects the recovery of the specimen after a certain period of time under a load. It is suitable for any fiber pure or blended fabric test. Besides, it can not maintain the shape of stable materials under the characteristics of the conditions, such as the material which is soft, thin and easy to bend. We can evaluate its anti-crease performance through this device.
Technical Parameters
Standards:
AATCC 128Wrinkle recovery of fabrics: Appearance method
ISO 9867Textiles - Evaluation of the wrinkle recovery of fabrics - Appearance method
ENKA 306International standard that specifies the methodology for evaluating thewrinkle recovery performanceof textiles, particularly for fabrics prone to deformation under pressure
ISO 9867Textiles - Evaluation of the wrinkle recovery of fabrics - Appearance method
ENKA 306International standard that specifies the methodology for evaluating thewrinkle recovery performanceof textiles, particularly for fabrics prone to deformation under pressure
Accessories:
(1)First ,use the pressure sample device, three samples are tested continuously. The interval is about 1min;
(2)Fold the sample face to face. Cloth edge clip with a clip, not more than 5mm;
(3)In some cases the sample surface will be stained together. We should use a piece of paper or aluminum foil whose size is 18x14mm. Be careful not to contact the sample by hand;
(4)Place the folded sample between the two briquettes and apply the weight immediately. Turn on the chronograph and wait 60 + 2 seconds. Prepare the next sample according to 2,3,4 steps.
(5)After 5 minutes, remove the first piece of weight quickly and easily. Transfer the folded sample with the clip to the sample rack of the measuring instrument;
(6)Remove the paper or aluminum foil. Place one side of the sample in the sample holder and the other side is the free hanging. After 60 +2 seconds, Put the second and third pieces of samples into the sample folder;
(7)Adjust the instrument so that the hanging end of the sample is consistent with the vertical mark of the instrument, within 5min should be constantly adjusted (so that the hanging end of the sample is consistent with the vertical mark of the instrument,) to avoid the impact of gravity;
(8)After 5 minutes, record the recovery angle of the sample. If the sagging side is slightly curled or twisted to pass through the vertical plane of the center of the droop and the axis of the dial as a reference for the crease return angle reading;
(9)Repeat the above steps, and then do three negative fold of the sample and the zonal frontal fold and the opposite fold (a total of 12).
(2)Fold the sample face to face. Cloth edge clip with a clip, not more than 5mm;
(3)In some cases the sample surface will be stained together. We should use a piece of paper or aluminum foil whose size is 18x14mm. Be careful not to contact the sample by hand;
(4)Place the folded sample between the two briquettes and apply the weight immediately. Turn on the chronograph and wait 60 + 2 seconds. Prepare the next sample according to 2,3,4 steps.
(5)After 5 minutes, remove the first piece of weight quickly and easily. Transfer the folded sample with the clip to the sample rack of the measuring instrument;
(6)Remove the paper or aluminum foil. Place one side of the sample in the sample holder and the other side is the free hanging. After 60 +2 seconds, Put the second and third pieces of samples into the sample folder;
(7)Adjust the instrument so that the hanging end of the sample is consistent with the vertical mark of the instrument, within 5min should be constantly adjusted (so that the hanging end of the sample is consistent with the vertical mark of the instrument,) to avoid the impact of gravity;
(8)After 5 minutes, record the recovery angle of the sample. If the sagging side is slightly curled or twisted to pass through the vertical plane of the center of the droop and the axis of the dial as a reference for the crease return angle reading;
(9)Repeat the above steps, and then do three negative fold of the sample and the zonal frontal fold and the opposite fold (a total of 12).
Technical Parameters
| Items | Parameters |
| Sample size | 15cm×28cm(6×11inch) |
| Weights | 2000g,1000g,500kg,200kg Accumulate |
| Dimensions | 150×150×330mm(L×W×H) |
| Weight | 9.5kg(21lb) |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Carpet Peel Strength and Tuft Bond Tester | Product Details For tufted carpets or traditional carpets, an important parameter is the retention performance of their tufts. Poor - quality car... | |
| Spread of Flame Test Apparatus | Description This machineis designed according to ISO5658-2 standard D andproduction,while meeting the IMO FTP Code Resolution A. 653 (16) and ASTM... | |
| Chest Drainage meter | The thoracic drainage tester is widely applied in the medical field, mainly used for monitoring and evaluating the performance of thoracic drainage... | |
| Seat Bumping and Creep Test Bench | This test bench is used for simulating the car seat bumping and creep situation when a car is running. This instrument can perform car seat bumping... | |
| Large scale Calorimeter | Product details According to the heat release rate, calorie is divided into several types. The most common calorimeters include a cone calorimeter... |
Похожие товары
| Liquid Sliding Penetration Comprehensive Performance Tester | Продавец: Qinsun Instruments Co., LTD | G373 Liquid penetrating and strike-through comprehensive performance tester - Penetrability test ... | |
| Nonwovens liquid loss tester | Продавец: Qinsun Instruments Co., LTD | Nonwovens liquid loss tester built-in loss of Taiwan and sample fixture for non-woven fabric mate... | |
| Elmendorf Tearing Strength Tester | Продавец: Qinsun Instruments Co., LTD | G008 Manual Tearing Tester - Material Tear Resistance Test G008Manual Tearing Tester, The Elmend... | |
| Dry Cleaning & Washing Cylinder | Продавец: Qinsun Instruments Co., LTD | IntroductionThe dry cleaning and washing cylinder consists of a stainless steel rotary test chamb... | |
| Rotary Rubbing Color Fastness Tester (Crockmeter) | Продавец: Qinsun Instruments Co., LTD | Standard AATCC 116: Colorfastness to Crocking (American Association of Textile Chemists and Co... |