Automotive Connector SO₂/H₂S Corrosion Test Chamber

Standards:

GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosion testing.

GJB 150: China’s military-grade environmental testing specifications.

QC/T 417.1-2001: Automotive industry standard for electric connector corrosion resistance.

Equivalent International Standards: IEC 60068-2-43. DIN 50018. MIL-STD-810G, ASTM G85 (Annex A5).

Technical Parameters:

1. Temperature range: 10 - 55°C

2. Temperature fluctuation: ±0.5°C

3. Temperature uniformity: ±2°C

4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm)

5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm)

6. Relative humidity: 75±3%

7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.

Environmental Requirements:

1. Power supply: AC380V 3Φ 10KVA 0HZ

2. Allowable voltage range: ±5% of the rated value

3. Maximum load: 6KVA

4. The distance between the chamber and the wall should be greater than 600cm.

Structural Materials and Features:

1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean. 2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens.

3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber.

4. Humidification method: Humidification by a steam generator.

5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors.

6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).

Control System:

1. Temperature control: Japanese Fuji temperature controller

2. Temperature input: PT100; Output: Driven by SSR

3. Display range: 0 - 100°C

4. Control range: RT + 5 - 55°C

5. Cycle used (measurement filtering): 2 - 3s

6. The main control components are products from joint - venture companies.

7. The temperature is controlled by a solid - state relay, with stable performance and no noise.

8. A fan is used for stirring and circulation inside the chamber. 9. Display and control of sulfur dioxide concentration


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

 Flatbed Ironing Tester
Flatbed Ironing Tester Product Overview TheFlatbed Ironing Testeris a precision instrument designed to evaluate fabric performance under simulated ironing conditions. It...
Vapor Shrinkage Tester
Vapor Shrinkage Tester I. Product Overview TheVapor Shrinkage Testeris a specialized thermal analysis instrument designed to measure dimensional changes in textiles, pol...
 Veslic Multi-Functional Material Tester for Advanced Quality Control-QINSUN
Veslic Multi-Functional Material Tester for Advanced Quality Control-QINSUN Standard ISO 13934-1(Tensile Properties of Fabrics) ASTM D624(Tear Strength of Rubber and Elastomers) AATCC 135(Dimensional Changes in Textiles ...
Qinsun UV-master
Qinsun UV-master In response to the climate resistance testing requirements for outdoor textiles, this equipment can simulate outdoor climate conditions and accel...
Paper stiffness tester
Paper stiffness tester Compliance Standards: ISO 5628、ISO 2493 TAPPI T489、TAPPI T556、JIS P 8125 Product Introduction: ZY-TDY300 microcomputer bending stiffness tester...
Все товары поставщика

Похожие товары

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Продавец: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Продавец: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Продавец: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Продавец: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Продавец: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...