Automotive Connector SO₂/H₂S Corrosion Test Chamber

Standards:

GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosion testing.

GJB 150: China’s military-grade environmental testing specifications.

QC/T 417.1-2001: Automotive industry standard for electric connector corrosion resistance.

Equivalent International Standards: IEC 60068-2-43. DIN 50018. MIL-STD-810G, ASTM G85 (Annex A5).

Technical Parameters:

1. Temperature range: 10 - 55°C

2. Temperature fluctuation: ±0.5°C

3. Temperature uniformity: ±2°C

4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm)

5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm)

6. Relative humidity: 75±3%

7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.

Environmental Requirements:

1. Power supply: AC380V 3Φ 10KVA 0HZ

2. Allowable voltage range: ±5% of the rated value

3. Maximum load: 6KVA

4. The distance between the chamber and the wall should be greater than 600cm.

Structural Materials and Features:

1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean. 2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens.

3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber.

4. Humidification method: Humidification by a steam generator.

5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors.

6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).

Control System:

1. Temperature control: Japanese Fuji temperature controller

2. Temperature input: PT100; Output: Driven by SSR

3. Display range: 0 - 100°C

4. Control range: RT + 5 - 55°C

5. Cycle used (measurement filtering): 2 - 3s

6. The main control components are products from joint - venture companies.

7. The temperature is controlled by a solid - state relay, with stable performance and no noise.

8. A fan is used for stirring and circulation inside the chamber. 9. Display and control of sulfur dioxide concentration


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

MST Medical Compression Stocking Tester
MST Medical Compression Stocking Tester Product Overview TheMST Medical Compression Stocking Testeris a specialized instrument designed to evaluate the compression performance, elasticit...
Automotive Wire Scratch Resistance Tester
Automotive Wire Scratch Resistance Tester Standards The tester adheres to global standards for material abrasion testing, including: ISO 6722-1(Road vehicles – Electrical cables &nd...
Automotive Connectors Salt Spray Tester -QINSUN
Automotive Connectors Salt Spray Tester -QINSUN
Static Tensile Tester-QINSUN
Static Tensile Tester-QINSUN Standard ASTM D3107Ensurereliable measurement of fabric elongation and tensile properties under controlled force applications. Product Advantages...
Automotive Seat Belt Buckle Bending Test Machine-QINSUN
Automotive Seat Belt Buckle Bending Test Machine-QINSUN Standard ISO 10195(Seat Belt Anchorage Hardware - Test Methods) ECE R16(Uniform Provisions Concerning the Approval of Safety Belts and Restrain...
Все товары поставщика

Похожие товары

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Продавец: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Продавец: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Продавец: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Продавец: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Продавец: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...